1. Introduction

1.1 General

The following instructions are offered as a guide to the 
user and installer.

The installation must be carried out by a competent 
plumbing and electrical installer in accordance with 
Building Regulation G3 (England and Wales), Technical 
Standard P3 (Scotland) or Building Regulation P5 
(Northern Ireland) and the Water Fitting Regulations 
(England and Wales) or Water Byelaws (Scotland). 

1.2 Symbols used

In these instructions, various risk levels are employed 
to draw the user’s attention to particular information. In 
doing so we wish to safeguard the user, avoid hazards 
and guarantee the correct operation of the appliance.

DANGER

Risk of a dangerous situation causing serious 
physical injury.

WARNING

Risk of dangerous situation causing slight 
physical injury.

CAUTION

Risk of material damage.

 

Signals important information.

1.3 Abbreviations

 

`

T&P - Temperature & Pressure relief valve

 

`

PRV - Pressure Reducing Valve

 

`

Prv - Pressure relief valve

1.4 Liabilities

Manufacturers liability
Our products are manufactured in compliance with 
the requirements of the various applicable European 
Directives. 

This appliance complies with the requirements of the 
CE marking directive.

In the interest of UK customers, we are continuously 
endeavouring to make improvements in product 
quality. All the specifications stated in this document 
are therefore subject to change without notice.

Our liability as the manufacturer may not be invoked in 
the following cases:

 

`

Failure to abide by the instructions on using the 
appliance.

 

`

Faulty or insufficient maintenance of the appliance.

 

`

Failure to abide by the instructions on installing the 
product.

Installer's liability
The installer is responsible for the installation and the 
commissioning of the appliance. The installer must 
respect the following instructions:

 

`

Read and follow the instructions given in the 
manuals provided with the appliance.

 

`

Carry out installation in compliance with the 
prevailing legislation and standards.

 

`

Perform the initial start up and carry out any checks 
necessary.

 

`

Complete the commissioning checklist.

 

`

Explain the installation to the user.

 

`

If maintenance is necessary, warn the user of the 
obligation to check the appliance  and maintain it 
in good working order.

 

`

Give all the instruction manuals to the user.

Users liability
To guarantee optimum operation of the appliance, the 
user must respect the following instructions:

 

`

Read and follow the instructions given in the 
manuals provided with the appliance.

 

`

Call on qualified professionals to carry out 
installation and initial start up.

 

`

Get your installer to explain your installation to you.

 

`

Have your required checks and services done.

 

`

Keep the instruction manuals in good condition 
and close to the appliance.

This appliance can be used by children aged 
from 8 years and above and persons with 

reduced physical sensory or mental capabilities 
or lack of experience and knowledge if they 
have been given supervision or instruction 
concerning use of the appliance in a safe 
way and understand the hazards involved. 
Children shall not play with the appliance. 
Cleaning and user maintenance shall not be 
made by children without supervision.

Children must be supervised to ensure they 
do not play with the appliance.

Содержание PremierPlus

Страница 1: ...PremierPlus Unvented Hot Water Cylinder Installation and User Manual...

Страница 2: ...ntenance operations 21 10 Troubleshooting 22 10 1 Fault finding 22 11 Decommissioning 23 11 1 Decommissioning procedure 23 12 1 Spare parts list 23 Benchmark checklist 25 Commissioning service records...

Страница 3: ...appliance Faulty or insufficient maintenance of the appliance Failure to abide by the instructions on installing the product Installer s liability The installer is responsible for the installation and...

Страница 4: ...and the mains water supply Do not switch on if there is a possibility that the water in the cylinder is frozen DANGER This cylinder is unvented and as such becomes pressurisedwheninoperation Thecombin...

Страница 5: ...ssure 1 6MPa 16 bar Max design pressure 0 8MPa 8 bar Max operating pressure PRV 0 35MPa 3 5 bar Expansion relief valve setting 0 6MPa 6 bar T P valve setting 1 0MPa 10 bar 90 C Maximum primary pressur...

Страница 6: ...199 246 295 295 355 355 Weight empty kg 23 25 28 29 36 45 45 55 55 Max supply pressure 1 6MPa 16 bar Max design pressure 0 8MPa 8 bar Max operating pressure PRV 0 35MPa 3 5 bar Max expansion vessel c...

Страница 7: ...170E 210E 250E 300E B 306 306 306 306 306 306 306 C 493 616 800 925 1184 1437 1751 D 784 906 1090 1216 1474 1726 2040 Item 100B 120B 150B 170B 210B 250B 300B A 315 315 315 315 315 315 315 B 354 354 35...

Страница 8: ...s with controls selected A double pole isolating switch must be installed in the mains supply All earth connections must be connected back to the mains earth supply 3 DHW OFF 2 3 L 1 N 2 3 HTG ON DHW...

Страница 9: ...3 Control Housing Details Element Connections 1 5mm 3 Core HOFR sheathed cable Indirect control wiring N L 1 5mm 3 Core HOFR sheathed cable Figure 5 Direct wiring schematic Figure 4 Indirect wiring s...

Страница 10: ...ions as listed below Building Regulations G3 The Building Standards Scotland The Building Regulations Northern Ireland I E E Electrical Regs UK Water Regulations 5 1 Installation regulations 5 2 Insta...

Страница 11: ...r supplies that have either inadequate pressure or where the supply may be intermittent Situations where it is not possible to safely pipe away any discharge from the safety valves In areas where the...

Страница 12: ...connection if required Cold water combination valve Mains water supply Isolating valve not supplied Discharge pipe Tundish Drain cock not supplied Secondary return if required use swept tee Inlet NOTE...

Страница 13: ...d with the discharge pipework in either the horizontal position or facing downwards Where discharge pipework is difficult to attain the local building control officer from the local council should be...

Страница 14: ...onze circulation pump will be required On large systems due to the increase in system water content it may be necessary to fit an additional expansion vessel to the secondary circuit This should be do...

Страница 15: ...nd lower than the valve with no more than 600mm of pipe between the valve outlet and the tundish see fig 10 Note To comply with the Water Supply Water Fittings Regulations the tundish should incorpora...

Страница 16: ...e continuously marked with a warning that no sanitary appliances should be connected to the pipe Note 1 Plastic pipes should be joined and assembled with fittings appropriate to the circumstances in w...

Страница 17: ...p to 27m 1 4m 1 7m 2 3m Table 5 Sizing of copper discharge pipe D2 for common temperature relief valve outlet sizes Safety device e g Temperature relief valve Metal discharge pipe D1 from Temperature...

Страница 18: ...e unit within the central heating system Other controls will be necessary to control the space heating requirements and times that the system is required to function The cylinder is compatible with mo...

Страница 19: ...hermostat s and that no water has discharged from the expansion relief valve or temperature pressure relief valve during the heating cycle Indirect units Fill the indirect primary circuit following th...

Страница 20: ...direct units immersion heater s All immersion heaters are fitted with a combined thermostat and thermal cut out located under the terminal cover mounted on the side of the product Access to the therm...

Страница 21: ...ply and turn off boiler Attachahosepipetothedraincockhavingsufficient length to take water to a suitable discharge point below the level of the unit Open a hot tap close to the unit and open drain coc...

Страница 22: ...rect thermostat Indirect motorised valve not connected correctly Check wiring and or plumbing connections to motorised valve Water discharges from expansion valve Intermittently Expansion vessel charg...

Страница 23: ...Pressure reducing valve cartridge 3 5 bar 95605898 11 Temperature Pressure Relief Valve 95605810 12 Expansion vessel 12 litre 100 120 and 150 litre models not shown 95607863 13 Expansion vessel 18 lit...

Страница 24: ...ure 12 Exploded view of cold water combination valve Cold Mains Connection 22mm Outlet Connection 22mm Outlet Connection 15mm 9 10 7 8 4 3 17 11 20 17 18 1 19 3 4 2 22 22 23 Figure 13 Cylinder explode...

Страница 25: ...set temperature C I min Yes Type of control system if applicable Y Plan S Plan Other Is the cylinder solar or other renewable compatible Yes No What is the hot water temperature at the nearest outlet...

Страница 26: ...Telephone No Comments Signature SERVICE 07 Date Engineer name Company name Telephone No Comments Signature SERVICE 09 Date Engineer name Company name Telephone No Comments Signature SERVICE 02 Date E...

Страница 27: ...subjected to frost nor has it been tampered with or been subject to misuse or neglect No factory fitted parts have been removed for un authorised repair or replacement The Benchmark commisioning chec...

Страница 28: ...te responsibility and sustainability charters and reduce our printed material we encourage you to download product brochures from our website In designing these files we have taken into account the ne...

Отзывы: