8 Bar Pressure Relief (Expansion) Valve – supplied fitted (see figure 4)
This is installed between the 3 bar Pressure Reducing Valve and the Megaflo Eco SolaReady cylinder. Branches to drinking
water outlets should be taken before the Pressure Relief Valve to avoid the possibility of warm expanded water being drawn
from the tap.
The Pressure Relief (Expansion) Valve is supplied pre-plumbed to the inlet connection of the Megaflo Eco SolaReady unit.
No other valve should be fitted between the Pressure Relief (Expansion) Valve and the cylinder inlet.
Outlet to Megaflo
eco Solar
Mains in
22mm compression connection
Take note of flow
direction
Pressure reducing valve
cartridge (3 Bar)
22mm compression connection
Outlet to Megaflo
eco Solar
From cold water
Combination Valve
Take note of flow
direction
Pressure Relief Valve
discharge connection
Pressure Relief Valve
“TEE” ( incorporates
Check Valve )
Figure 3 – 3 Bar Pressure Reducing Valve
Figure 4 – 8 Bar Pressure Relief Valve