background image

ventilate the house properly and keep the temperature as

constant as possible.

Forced drying: not too fast

Heating the house to promote the drying process is

sometimes called forced drying. Forced drying should

not be done too quickly, otherwise significant damage

(such as contraction cracks) can occur. It is therefore

recommended to give careful attention to forced drying.

Bear in mind that the forced drying process may take as

long as six months. Set the heating to 15 to 18°C, and

raise it to 20°C after moving in. Do not set the heating

any higher, as the materials will start drying too quickly

and damage to the building structure may occur.

Ventilation during forced drying

Good ventilation and air circulation are essential during

the drying process. During the first year, keep furniture

approximately 5 cm away from the walls to allow the

moisture to escape. Open the windows each day for

sustained periods. The ventilation grilles must remain

open all the times and the forced air ventilation system

should be left to run constantly (don't unplug it), Run the

forced air ventilation system at high speed as often as

possible during the first few months.

This will create the most favourable air circulation in the

house.

Energy costs

Good, continuous ventilation is not only important for

good health; it is also important to avoid moisture

problems in the house. However, ventilation takes heat

out of the house. Forced drying new houses also results

in higher energy consumption, resulting in a higher

energy costs.

11

Содержание HRU ECO 4

Страница 1: ...HRU ECO 4 User manual...

Страница 2: ...Translation of the original document...

Страница 3: ...em or surrounding area Note Instructions important for the installation functioning operation or maintenance of the product Failure to observe these instructions can result in minor damage to the prod...

Страница 4: ...fiche information 12 2 8 Accessories 13 2 9 Recycling 13 3 Operation 14 3 1 Ventilation speeds 14 3 2 Devices 15 3 3 Sensors 15 3 4 Pairing and unpairing wireless devices and sensors 15 4 Inspection...

Страница 5: ...experience knowledge if under supervision or after having received instructions regarding safe use and if they are aware of the product and or system hazards Cleaning and maintenance by the user may...

Страница 6: ...pect the product regularly for faults In the event of faults switch the product off and contact your installer or Heatrae Sadia Customer Service immediately Switch the product off if The product is no...

Страница 7: ...ECO 4 ventilation system from Heatrae Sadia is an example of these advanced appliances The HRU ECO 4 is a balanced ventilation system with heat recovery The ventilation unit is equipped with two fans...

Страница 8: ...rgies who are sensitive to this During the product s lifetime the filters will become dirty which reduces the capacity of the ventilation unit It is therefore essential that the filters are cleaned as...

Страница 9: ...nergy efficient manner When the the CO2 level has fallen sufficiently the capacity of the ventilation unit is automatically decreased Tip It is possible to place several wireless sensors and controls...

Страница 10: ...2x s Bypass mode Lit Normal operation Pattern Function Red Orange Blinks 1x s Blinks 1x s Exhaust fan fault Blinks 1x s Blinks 2x s Supply fan fault Blinks 2x s Blinks 2x s Exhaust temperature sensor...

Страница 11: ...ring forced drying Good ventilation and air circulation are essential during the drying process During the first year keep furniture approximately 5 cm away from the walls to allow the moisture to esc...

Страница 12: ...Pmax W 154 Sound power level LWA dB 52 Reference flow rate qref m3 s 0 069 Reference pressure difference Pref Pa 50 Specific power input SPI W m3 h 0 255 Ventilation control Manual control no DCV Con...

Страница 13: ...n how to do so The product s packaging can be recycled These materials should be disposed of in a responsible manner in accordance with government regulations As a reminder of the need to dispose of b...

Страница 14: ...te The timer can be stopped at any time by pressing the button for low speed high speed or automatic mode Auto Night Auto Night raises the minimum ventilation speed to ensure sufficient ventilation du...

Страница 15: ...on page 15 3 4 Pairing and unpairing wireless devices and sensors 3 4 1 Pairing wireless devices Pairing a wireless control switch should be done in the vicinity of the ventilation unit a Switch off p...

Страница 16: ...he ventilation unit is switched on For more information consult the documentation provided with the relevant sensor The sensor is paired and the ventilation unit briefly changes speed to confirm the p...

Страница 17: ...heck for soiling and leakage 6 months 1 year Motor module Check for soiling imbalance 1 year Bypass valve Frost valve Check functioning and for soiling 1 year Heat exchanger Check for soiling 1 year A...

Страница 18: ...he filters as follows a Disconnect power to the ventilation unit b Remove both filter holders c Visually inspect the filters for soiling If the filters are dirty they must be cleaned or replaced d Cle...

Страница 19: ...me time Warning HRU ECO 4 should always be fitted with the appropriate filters Without filters the appliance can be irreparably damaged Note The dirty filter indication cannot be reset via the control...

Страница 20: ...ubber gaskets b Fully immerse the valves in a solution of a mild cleaning agent such as washing up liquid or all purpose cleaner If necessary the valves can be cleaned in a dishwasher c Wipe off the v...

Страница 21: ...an for soiling and clean it if necessary Check the fan for defects and replace it if necessary The status LED on the ventilation unit blinks once red and twice orange Cause Solution a The ventilation...

Страница 22: ...he unit will automatically return to normal operation Neither fan is rotating Cause Solution a The ventilation unit s plug is not plugged into a power socket Insert the plug into a power socket b The...

Страница 23: ...connected to the unit Check the connections and ensure that fixed ducts are clamped to the wall ceiling or floor e The bypass valve is blocked rattling noise The bypass valve strikes the stop during t...

Страница 24: ...nect the switch wires correctly see wiring diagram d The ventilation unit PCB is faulty Replace the PCB and carry out the commissioning procedure again The ventilation unit is leaking water Cause Solu...

Страница 25: ...g supplied to the dwelling Cause Solution a The filter in the extraction outlet is blocked Clean or replace the filter in the air outlet b The air valves are not correctly adjusted Put the ventilation...

Страница 26: ...claimer This warranty does not apply to Disassembly and assembly costs Faults which are caused by incorrect treatment Negligence or accident Faults that have been caused by repairs by third parties wi...

Страница 27: ...mmission Delegated Regulation EU No 1254 2014 of 11 July 2014 supplementing Directive 2010 30 EU of the European Parliament and of the Council with regard to energy labelling of residential ventilatio...

Страница 28: ...HEATRAE SADIA HEATING Hurricane Way Norwich NR6 6EA www heatraesadia com SERVICE 44 0 344 871 1535 EMAIL customer support heatraesadia com 01 02504 002 ID 2018 02 07 1426...