1.8 IT IS IMPORTANT TO CLEAN THE HANDSET SPRAY PLATE REGULARLY,

 particularly in hard water areas,

where this may be necessary as often as once a week. Failure to do so will affect the performance of the shower, and
in extreme cases may cause the pressure relief device to operate.

Refer to 

Section 6

.

1.9 The shower heater outlet, hose and handset act as a vent. They must not be blocked, obstructed, or
have connected to them any fitting not approved by us.

 The use of unapproved accessories may invalidate the

guarantee and affect the performance and safety of the unit.

1.10

 WARNING: DO NOT USE the shower if the HOSE IS DAMAGED in any way; for instance if the outer covering

has parted to reveal the inner tube. A damaged hose can suddenly restrict the flow and result in extremely hot water
from the spray head.

A damaged hose could completely block the outlet of the shower; the resulting increase in pressure could burst a
weakened or damaged hose.

1.11

 Do not install the shower in a situation where the water in it could freeze. Any damage caused by freezing will

not be covered by the guarantee.

WARNING. If you suspect your shower of being frozen, DO NOT SWITCH ON. If you have switched on,
SWITCH OFF IMMEDIATELY.

Refer to Fault-Finding, 

Section Five

.

Page 4

1.12

 Do not leave young children, the infirm or disabled unattended in the shower.

1.13

 Before stepping into the shower, always test the temperature of the spray with your hand.

1.14

 Switch off at the isolating switch after use. This is a safety procedure recommended with ALL electric

appliances.

1.15

 As with all electrical appliances, it is recommended to have your shower and installation checked at least every

two years by a competent electrician, to ensure there is no deterioration due to age and usage.

1.16

 Shampoo and shower gel should be stored using the gel hook and soap dish (where provided) and 

must not be

placed on top of the shower unit.

How an instant electric shower works

1.17

 In an instant electric shower, an electric element heats water AS IT PASSES THROUGH. The temperature of

the shower is adjusted by controlling the rate at which water flows over the heating element. This is done using a flow
control knob. There is no thermostat. If the temperature of the incoming water varies (mains water can be as low as
5°C in winter and as high as 20°C in summer), the output temperature will also vary. The shower is only able to
RAISE the temperature of the water by a given amount (depending upon the flow rate).

21/03/2011

www.partsarena.co.uk/baxi/System/DA…

partsarena.co.uk/baxi/…/I47-2835.htm

4/16

Содержание DART 2005

Страница 1: ...nd User Instructions Please read and understand these instructions before starting work Heatrae Sadia Heating Hurricane Way Norwich Norfolk NR6 6EA For Service enquiries call 01603 420330 Page 1 21 03 2011 www partsarena co uk baxi System DA partsarena co uk baxi I47 2835 htm 1 16 ...

Страница 2: ...Figure 1 0 Major Internal Components Figure 1 1 Internal Circuit Diagram Page 2 CONTENTS 21 03 2011 www partsarena co uk baxi System DA partsarena co uk baxi I47 2835 htm 2 16 ...

Страница 3: ...by a registered qualified and competent electrican who should carry out the installation taking into account the site conditions To meet the requirements of the Electrical Safety Standard EN 60335 4mm2 cable should not be used to install showers with a rating of more than 7 7kW at 240V and 6mm2 cable should not be used to install showers with a rating of more than 9 6kW at 240V 1 2 WARNING THIS AP...

Страница 4: ...ched on SWITCH OFF IMMEDIATELY Refer to Fault Finding Section Five Page 4 1 12 Do not leave young children the infirm or disabled unattended in the shower 1 13 Before stepping into the shower always test the temperature of the spray with your hand 1 14 Switch off at the isolating switch after use This is a safety procedure recommended with ALL electric appliances 1 15 As with all electrical applia...

Страница 5: ...a bit in good condition Sharp Stanley knife Round file Pipe cutters Electric drill and 7mm dia N 14 masonry bit Wire cutters Electrician s insulation strippers Other items you may need 15mm compression elbow or straight connector for connection to the shower unit 15mm isolating valve Things you must do 2 1 It is advisable to check that the water pressure to the shower is adequate If in doubt consu...

Страница 6: ...sufficient head of water 2 3 Mount the shower heater on a flat vertical wall with the outlet to which the hose is connected pointing downwards The shower must be securely fixed to the mounting surface using suitable mechanical fixings in the three mounting points Adhesive must not be used 2 4 Ensure that the shower heater is not in the direct spray of a normally parked handset 2 5 Allow room aroun...

Страница 7: ...ould be cut square and be free from internal and external burrs and deep scratches Where possible use a pipecutter and not a saw to prevent saw chippings entering the pipe Figure 2 10 2 11 Before making the final water connections to the shower heater the pipework MUST BE FLUSHED THOROUGHLY to remove brick dust swarf etc which could severely damage the shower itself See Fig 2 11 Figure 2 11 2 12 A...

Страница 8: ...witch off the whole installation at the consumer unit or switch fuse where fitted 3 3 It is strongly recommended that a 30mA rcd is incorporated in the circuit even if it is not required to comply with BS 7671 3 4 A double pole isolating switch with a contact separation of at least 3mm in each pole must be incorporated in the circuit This must have a mechanical indicator showing when the switch is...

Страница 9: ...ng If you must tile around the shower DO NOT grout right up to the shower backplate as this makes subsequent removal difficult Do not seal the shower to the wall using bath sealant as the shower will not be harmed by water dripping behind it 4 7 Remove the relevant areas of the backplate which are not knockouts using a sharp knife and or a round file Cable and Pipe Entries Cable Entry 4 8 Availabl...

Страница 10: ...gned to accept a 15mm compression fitting This must be an elbow for top bottom and rear entry and a straight connector for side entry See Fig 4 9 You should use compression rings olives made of copper rather than brass as copper will crush down better onto the plastic spigot Push fit connectors cannot be used 21 03 2011 www partsarena co uk baxi System DA partsarena co uk baxi I47 2835 htm 10 16 ...

Страница 11: ...raight connector with an overall length including nuts and olives of less than 42mm Plumbing 4 10 Decide where to connect to the water mains for your feed to the shower Ensure that the pipe you have selected is not a gas pipe they can look similar or a hot water pipe nor from a cold water storage tank unless you have sufficient head see Section 2 2 4 11 Cut the necessary pipework to length assembl...

Страница 12: ... removed from the wall 4 25 Feed the cable through the opening in the backplate below the terminal block 4 26 Ensure that all three screws hold the shower backplate to the wall firmly 4 27 Strip the outer insulation sheath back as required Strip the insulation from the cores and make connections to the LIVE L brown or red NEUTRAL N blue or black and EARTH terminal block The earth wire must be slee...

Страница 13: ...e desired temperature Turn clockwise for warmer anti clockwise for cooler Allow a few seconds after each adjustment for the temperature to stabilise The high low power selector push buttons allows you to choose the power used by the heater The low setting which uses less electricity can be used in the summer to decrease the spray temperature when the incoming water temperature is likely to be high...

Страница 14: ...hose b If the water does not flow there is a blockage in the plumbing to the shower or the shower itself Contact our Service Department if the shower is considered to be the problem 2 Flow adequate but water too cold A Shower heater is on the Low power setting A Ensure that shower is on High setting where applicable B Water flow too high B Reduce the flow by turning the water control knob clockwis...

Страница 15: ...ure circuit breaker mcb has operated in your fusebox or consumer unit or switch fuse A Switch off power and isolating switch Renew fuse or reset mcb If they operate a second time contact a qualified electrician B Residual current device rcd earth leakage circuit breaker has operated B Follow the same procedure as above If this has happened with a split load consumer unit on initial installation ch...

Страница 16: ...d of at a local authority waste disposal site to ensure the environmental benefits are realised Handsets It is recommended that periodically the handset is immersed and soaked in a proprietary descalant overnight Page 17 6 3 Maintenance a Cleaning the Handset To get the best performance from your shower the plate in the handset must be cleaned regularly maybe as often as once a week in hard water ...

Отзывы: