WARMER-

 DECREASE FLOW - TURN KNOB CLOCKWISE

COOLER-

 INCREASE FLOW - TURN KNOB ANTI-CLOCKWISE

Make adjustments carefully. Give the shower a few seconds after each adjustment to stabilise, then check the
temperature by hand before stepping into the shower. The 'low' setting cuts out one heating element and so can be
used to save energy in the summer months when incoming water temperatures are higher, or simply to reduce the
spray temperature.

A cold shower can be obtained by leaving the isolating switch off.

6.2 To turn off:

(a) Turn water control knob fully clockwise.

(b) Turn off your isolating switch.

Environmental Information

This product is made from many recyclable materials, therefore at the end of its useful life it should be disposed of at
a local authority waste disposal site to ensure the environmental benefits are realised.

Handsets

It is recommended that periodically the handset is immersed and soaked in a proprietary descalant
overnight.

Page 17

6.3 Maintenance

(a) Cleaning the Handset:

To get the best performance from your shower, the plate in the handset must be cleaned regularly, maybe as often as
once a week in hard water areas.

This is because the fine outlet holes can become restricted with scale, and this will affect the pattern of the spray and
cause the heater to perform poorly.

For details of the cleaning procedure please refer to the instructions in the accessories box.

(b) Inspection:

We recommend that in the interests of safety the shower and its electrical installation is checked by a qualified
electrician at least every two years.

Page 18

Notes

Page 19

21/03/2011

www.partsarena.co.uk/baxi/System/DA…

partsarena.co.uk/baxi/…/I47-2835.htm

16/16

Содержание DART 2005

Страница 1: ...nd User Instructions Please read and understand these instructions before starting work Heatrae Sadia Heating Hurricane Way Norwich Norfolk NR6 6EA For Service enquiries call 01603 420330 Page 1 21 03 2011 www partsarena co uk baxi System DA partsarena co uk baxi I47 2835 htm 1 16 ...

Страница 2: ...Figure 1 0 Major Internal Components Figure 1 1 Internal Circuit Diagram Page 2 CONTENTS 21 03 2011 www partsarena co uk baxi System DA partsarena co uk baxi I47 2835 htm 2 16 ...

Страница 3: ...by a registered qualified and competent electrican who should carry out the installation taking into account the site conditions To meet the requirements of the Electrical Safety Standard EN 60335 4mm2 cable should not be used to install showers with a rating of more than 7 7kW at 240V and 6mm2 cable should not be used to install showers with a rating of more than 9 6kW at 240V 1 2 WARNING THIS AP...

Страница 4: ...ched on SWITCH OFF IMMEDIATELY Refer to Fault Finding Section Five Page 4 1 12 Do not leave young children the infirm or disabled unattended in the shower 1 13 Before stepping into the shower always test the temperature of the spray with your hand 1 14 Switch off at the isolating switch after use This is a safety procedure recommended with ALL electric appliances 1 15 As with all electrical applia...

Страница 5: ...a bit in good condition Sharp Stanley knife Round file Pipe cutters Electric drill and 7mm dia N 14 masonry bit Wire cutters Electrician s insulation strippers Other items you may need 15mm compression elbow or straight connector for connection to the shower unit 15mm isolating valve Things you must do 2 1 It is advisable to check that the water pressure to the shower is adequate If in doubt consu...

Страница 6: ...sufficient head of water 2 3 Mount the shower heater on a flat vertical wall with the outlet to which the hose is connected pointing downwards The shower must be securely fixed to the mounting surface using suitable mechanical fixings in the three mounting points Adhesive must not be used 2 4 Ensure that the shower heater is not in the direct spray of a normally parked handset 2 5 Allow room aroun...

Страница 7: ...ould be cut square and be free from internal and external burrs and deep scratches Where possible use a pipecutter and not a saw to prevent saw chippings entering the pipe Figure 2 10 2 11 Before making the final water connections to the shower heater the pipework MUST BE FLUSHED THOROUGHLY to remove brick dust swarf etc which could severely damage the shower itself See Fig 2 11 Figure 2 11 2 12 A...

Страница 8: ...witch off the whole installation at the consumer unit or switch fuse where fitted 3 3 It is strongly recommended that a 30mA rcd is incorporated in the circuit even if it is not required to comply with BS 7671 3 4 A double pole isolating switch with a contact separation of at least 3mm in each pole must be incorporated in the circuit This must have a mechanical indicator showing when the switch is...

Страница 9: ...ng If you must tile around the shower DO NOT grout right up to the shower backplate as this makes subsequent removal difficult Do not seal the shower to the wall using bath sealant as the shower will not be harmed by water dripping behind it 4 7 Remove the relevant areas of the backplate which are not knockouts using a sharp knife and or a round file Cable and Pipe Entries Cable Entry 4 8 Availabl...

Страница 10: ...gned to accept a 15mm compression fitting This must be an elbow for top bottom and rear entry and a straight connector for side entry See Fig 4 9 You should use compression rings olives made of copper rather than brass as copper will crush down better onto the plastic spigot Push fit connectors cannot be used 21 03 2011 www partsarena co uk baxi System DA partsarena co uk baxi I47 2835 htm 10 16 ...

Страница 11: ...raight connector with an overall length including nuts and olives of less than 42mm Plumbing 4 10 Decide where to connect to the water mains for your feed to the shower Ensure that the pipe you have selected is not a gas pipe they can look similar or a hot water pipe nor from a cold water storage tank unless you have sufficient head see Section 2 2 4 11 Cut the necessary pipework to length assembl...

Страница 12: ... removed from the wall 4 25 Feed the cable through the opening in the backplate below the terminal block 4 26 Ensure that all three screws hold the shower backplate to the wall firmly 4 27 Strip the outer insulation sheath back as required Strip the insulation from the cores and make connections to the LIVE L brown or red NEUTRAL N blue or black and EARTH terminal block The earth wire must be slee...

Страница 13: ...e desired temperature Turn clockwise for warmer anti clockwise for cooler Allow a few seconds after each adjustment for the temperature to stabilise The high low power selector push buttons allows you to choose the power used by the heater The low setting which uses less electricity can be used in the summer to decrease the spray temperature when the incoming water temperature is likely to be high...

Страница 14: ...hose b If the water does not flow there is a blockage in the plumbing to the shower or the shower itself Contact our Service Department if the shower is considered to be the problem 2 Flow adequate but water too cold A Shower heater is on the Low power setting A Ensure that shower is on High setting where applicable B Water flow too high B Reduce the flow by turning the water control knob clockwis...

Страница 15: ...ure circuit breaker mcb has operated in your fusebox or consumer unit or switch fuse A Switch off power and isolating switch Renew fuse or reset mcb If they operate a second time contact a qualified electrician B Residual current device rcd earth leakage circuit breaker has operated B Follow the same procedure as above If this has happened with a split load consumer unit on initial installation ch...

Страница 16: ...d of at a local authority waste disposal site to ensure the environmental benefits are realised Handsets It is recommended that periodically the handset is immersed and soaked in a proprietary descalant overnight Page 17 6 3 Maintenance a Cleaning the Handset To get the best performance from your shower the plate in the handset must be cleaned regularly maybe as often as once a week in hard water ...

Отзывы: