YOUR SHOWER
Recognition of major components
Circuit Diagram
SECTION ONE
Important information for installers and users
How an instantaneous shower works
SECTION TWO
Siting and Plumbing
SECTION THREE
Electrical Installation
SECTION FOUR
Connecting the shower to services
SECTION FIVE
Fault-Finding
SECTION SIX
User Instructions
NB Due to product variations the precise appearance of your shower may not be exactly as depicted in this leaflet.
Dimensions and functioning are unaffected.
Page 3
SECTION ONE Important Information
Your shower is designed and tested to the very highest standards and complies fully with all of the relevant
national/international standards for safety and reliability.
The shower is manufactured in a BS EN ISO 9001:2000-registered factory - your assurance of a quality product.
To ensure correct use and maintenance of the shower, please read and adhere to the following warnings and
guidelines.
For Installers:
1.1
The Installation must comply with the Building Regulations Part P and the Water Regulations. Where there is a
new installation, or a replacement product is not identical to the one being replaced, the cable sizes, circuit protective
devices, bonding and other requirements of the Building Regulations must be assessed by a (registered) qualified and
competent electrican, who should carry out the installation taking into account the site conditions. To meet the
requirements of the Electrical Safety.
Standard (EN 60335), 4mm
2
cable should not be used to install showers with a rating of more than 7.7kW (at 240V)
and 6mm
2
cable should not be used to install showers with a rating of more than 9.6kW (at 240V).
1.2 WARNING: THIS APPLIANCE MUST BE EARTHED.
1.3
Before removing your shower heater cover always ensure your shower heater is isolated from the electrical mains.
1.4
This product is splash-proof, and is approved for use in shower cubicles and over baths. However, do not install
the shower heater in a position where the handset, in its normally-parked position, will consistently direct spray over
it.
1.5
To comply with the Water Regulations a servicing valve must be fitted in the pipework to the shower, in an
accessible place. This will be of great benefit if any maintenance work, or complete replacement of the shower, is
required later on.
1.6
This shower is designed for domestic use and is not vandal-resistant. If it is installed in an institutional or
commercial situation, frequent inspection may be necessary, and our guarantee may be affected.
For Users:
1.7
If water emerges from anywhere other than the spray head outlets, do not use your shower, and refer to the fault-
finding section.
21/03/2011
www.partsarena.co.uk/baxi/System/DA…
partsarena.co.uk/baxi/…/I47-2835.htm
3/16