background image

YOUR SHOWER

 Recognition of major components

Circuit Diagram

SECTION ONE

 Important information for installers and users

How an instantaneous shower works

SECTION TWO

 Siting and Plumbing

SECTION THREE

 Electrical Installation

SECTION FOUR

 Connecting the shower to services

SECTION FIVE

 Fault-Finding

SECTION SIX

 User Instructions

NB Due to product variations the precise appearance of your shower may not be exactly as depicted in this leaflet.
Dimensions and functioning are unaffected.

Page 3

SECTION ONE Important Information

Your shower is designed and tested to the very highest standards and complies fully with all of the relevant
national/international standards for safety and reliability.

The shower is manufactured in a BS EN ISO 9001:2000-registered factory - your assurance of a quality product.

To ensure correct use and maintenance of the shower, please read and adhere to the following warnings and
guidelines.

For Installers:

1.1

 The Installation must comply with the Building Regulations Part P and the Water Regulations. Where there is a

new installation, or a replacement product is not identical to the one being replaced, the cable sizes, circuit protective
devices, bonding and other requirements of the Building Regulations must be assessed by a (registered) qualified and
competent electrican, who should carry out the installation taking into account the site conditions. To meet the
requirements of the Electrical Safety.

Standard (EN 60335), 4mm

2

 cable should not be used to install showers with a rating of more than 7.7kW (at 240V)

and 6mm

2

 cable should not be used to install showers with a rating of more than 9.6kW (at 240V).

1.2 WARNING: THIS APPLIANCE MUST BE EARTHED.

1.3

 Before removing your shower heater cover always ensure your shower heater is isolated from the electrical mains.

1.4

 This product is splash-proof, and is approved for use in shower cubicles and over baths. However, do not install

the shower heater in a position where the handset, in its normally-parked position, will consistently direct spray over
it.

1.5

 To comply with the Water Regulations a servicing valve must be fitted in the pipework to the shower, in an

accessible place. This will be of great benefit if any maintenance work, or complete replacement of the shower, is
required later on.

1.6

 This shower is designed for domestic use and is not vandal-resistant. If it is installed in an institutional or

commercial situation, frequent inspection may be necessary, and our guarantee may be affected.

For Users:

1.7

 If water emerges from anywhere other than the spray head outlets, do not use your shower, and refer to the fault-

finding section.

21/03/2011

www.partsarena.co.uk/baxi/System/DA…

partsarena.co.uk/baxi/…/I47-2835.htm

3/16

Содержание DART 2005

Страница 1: ...nd User Instructions Please read and understand these instructions before starting work Heatrae Sadia Heating Hurricane Way Norwich Norfolk NR6 6EA For Service enquiries call 01603 420330 Page 1 21 03 2011 www partsarena co uk baxi System DA partsarena co uk baxi I47 2835 htm 1 16 ...

Страница 2: ...Figure 1 0 Major Internal Components Figure 1 1 Internal Circuit Diagram Page 2 CONTENTS 21 03 2011 www partsarena co uk baxi System DA partsarena co uk baxi I47 2835 htm 2 16 ...

Страница 3: ...by a registered qualified and competent electrican who should carry out the installation taking into account the site conditions To meet the requirements of the Electrical Safety Standard EN 60335 4mm2 cable should not be used to install showers with a rating of more than 7 7kW at 240V and 6mm2 cable should not be used to install showers with a rating of more than 9 6kW at 240V 1 2 WARNING THIS AP...

Страница 4: ...ched on SWITCH OFF IMMEDIATELY Refer to Fault Finding Section Five Page 4 1 12 Do not leave young children the infirm or disabled unattended in the shower 1 13 Before stepping into the shower always test the temperature of the spray with your hand 1 14 Switch off at the isolating switch after use This is a safety procedure recommended with ALL electric appliances 1 15 As with all electrical applia...

Страница 5: ...a bit in good condition Sharp Stanley knife Round file Pipe cutters Electric drill and 7mm dia N 14 masonry bit Wire cutters Electrician s insulation strippers Other items you may need 15mm compression elbow or straight connector for connection to the shower unit 15mm isolating valve Things you must do 2 1 It is advisable to check that the water pressure to the shower is adequate If in doubt consu...

Страница 6: ...sufficient head of water 2 3 Mount the shower heater on a flat vertical wall with the outlet to which the hose is connected pointing downwards The shower must be securely fixed to the mounting surface using suitable mechanical fixings in the three mounting points Adhesive must not be used 2 4 Ensure that the shower heater is not in the direct spray of a normally parked handset 2 5 Allow room aroun...

Страница 7: ...ould be cut square and be free from internal and external burrs and deep scratches Where possible use a pipecutter and not a saw to prevent saw chippings entering the pipe Figure 2 10 2 11 Before making the final water connections to the shower heater the pipework MUST BE FLUSHED THOROUGHLY to remove brick dust swarf etc which could severely damage the shower itself See Fig 2 11 Figure 2 11 2 12 A...

Страница 8: ...witch off the whole installation at the consumer unit or switch fuse where fitted 3 3 It is strongly recommended that a 30mA rcd is incorporated in the circuit even if it is not required to comply with BS 7671 3 4 A double pole isolating switch with a contact separation of at least 3mm in each pole must be incorporated in the circuit This must have a mechanical indicator showing when the switch is...

Страница 9: ...ng If you must tile around the shower DO NOT grout right up to the shower backplate as this makes subsequent removal difficult Do not seal the shower to the wall using bath sealant as the shower will not be harmed by water dripping behind it 4 7 Remove the relevant areas of the backplate which are not knockouts using a sharp knife and or a round file Cable and Pipe Entries Cable Entry 4 8 Availabl...

Страница 10: ...gned to accept a 15mm compression fitting This must be an elbow for top bottom and rear entry and a straight connector for side entry See Fig 4 9 You should use compression rings olives made of copper rather than brass as copper will crush down better onto the plastic spigot Push fit connectors cannot be used 21 03 2011 www partsarena co uk baxi System DA partsarena co uk baxi I47 2835 htm 10 16 ...

Страница 11: ...raight connector with an overall length including nuts and olives of less than 42mm Plumbing 4 10 Decide where to connect to the water mains for your feed to the shower Ensure that the pipe you have selected is not a gas pipe they can look similar or a hot water pipe nor from a cold water storage tank unless you have sufficient head see Section 2 2 4 11 Cut the necessary pipework to length assembl...

Страница 12: ... removed from the wall 4 25 Feed the cable through the opening in the backplate below the terminal block 4 26 Ensure that all three screws hold the shower backplate to the wall firmly 4 27 Strip the outer insulation sheath back as required Strip the insulation from the cores and make connections to the LIVE L brown or red NEUTRAL N blue or black and EARTH terminal block The earth wire must be slee...

Страница 13: ...e desired temperature Turn clockwise for warmer anti clockwise for cooler Allow a few seconds after each adjustment for the temperature to stabilise The high low power selector push buttons allows you to choose the power used by the heater The low setting which uses less electricity can be used in the summer to decrease the spray temperature when the incoming water temperature is likely to be high...

Страница 14: ...hose b If the water does not flow there is a blockage in the plumbing to the shower or the shower itself Contact our Service Department if the shower is considered to be the problem 2 Flow adequate but water too cold A Shower heater is on the Low power setting A Ensure that shower is on High setting where applicable B Water flow too high B Reduce the flow by turning the water control knob clockwis...

Страница 15: ...ure circuit breaker mcb has operated in your fusebox or consumer unit or switch fuse A Switch off power and isolating switch Renew fuse or reset mcb If they operate a second time contact a qualified electrician B Residual current device rcd earth leakage circuit breaker has operated B Follow the same procedure as above If this has happened with a split load consumer unit on initial installation ch...

Страница 16: ...d of at a local authority waste disposal site to ensure the environmental benefits are realised Handsets It is recommended that periodically the handset is immersed and soaked in a proprietary descalant overnight Page 17 6 3 Maintenance a Cleaning the Handset To get the best performance from your shower the plate in the handset must be cleaned regularly maybe as often as once a week in hard water ...

Отзывы: