background image

Air

-M

neo

Содержание NeoAir V2-M

Страница 1: ...Air M neo...

Страница 2: ...1 Model Series Air M neo neo...

Страница 3: ...day Programming Optional Features Explained Adjusting the Optional Settings Optional Settings Feature Table Re calibrating the Thermostat Error Codes Factory Reset Remote Sensor Probe Wiring Mode 2 Ti...

Страница 4: ...l using the back plate as a positioning template Drill at the marked positions and insert a wall plug into each hole Step 3 Screw the thermostat back plate securely on the wall Step 4 Clip the front o...

Страница 5: ...4 Air M neo 1 2 3 4...

Страница 6: ...eoAir V2 M To access the battery holder push and release the compartment door located on the bottom face of the thermostat The thermostat will inform you when the batteries need to be replaced by disp...

Страница 7: ...o Insert the batteries in the empty battery holder ensuring that each battery is orientated for the correct polarity Push the battery holder back inside the thermostat until it is secured in its close...

Страница 8: ...Mode 3 Check the compatibility table below for the receiver you are using Use the Left arrow key to highlight on the menu Press and hold for 3 seconds SETUP is now highlighted press and hold for 10 se...

Страница 9: ...er to switch on the heating or hot water Select the receiver type you are using from the list shown here on pages 8 9 and follow the pairing instructions on the relevant page UH8 RF Wiring Centre Page...

Страница 10: ...9 Series neo RF Switch Page 12 RF Switch 16 Amp Page 13 neoHub Mini OT Page 14 15 neoHub Mini HW Page 16 17...

Страница 11: ...hold for 3 seconds SETUP is now highlighted press once to access the setup menu The display will show the number 01 in the top right hand corner Press the Down arrow key twice P2 is displayed in the t...

Страница 12: ...llflash thisrepresentsthezonetype rA Radiators UF Underfloor Heating Use the up down arrow keys to adjust between the two types Press once to confirm The two small numbers at the top will flash this r...

Страница 13: ...ce Thedisplaywillstartcountingdownfrom99 pairingmodeisnowactiveontheneoAir Onthe neoAir Onthe RF Switch PressandholdtheCH1buttonfor5seconds theCH1lightwillstartflashing pairing modeisnowactiveontheRF...

Страница 14: ...right corner Press once Thedisplaywillstartcountingdownfrom99 pairingmodeisnowactiveontheneoAir Onthe neoAir Onthe RF Switch 16 A Pressandholdthepairbuttonfor5seconds thepairlightwillstartflashing pa...

Страница 15: ...is active example shown below pairing to CH1 Air M neo Pairing with the neoHub Mini OT Configure the neoAir in mode 1 as explained on page 7 To control a single heating zone pair the neoAir to the CH...

Страница 16: ...ash in the top left corner of the display Navigate to on the menu Press once to return to the main neoAir display The next step is to pair the neoHub Mini OT with the neoApp Download the neoApp and re...

Страница 17: ...CH1 Pairing with the neoHub Mini HW Onthe neoHub Mini HW To control a single heating zone hot water configure the neoAir in mode 3 see page 7 then pair the neoAir to the CH1 output The neoAir will au...

Страница 18: ...ash in the top left corner of the display Navigate to on the menu Press once to return to the main neoAir display Once paired to the hub the mesh symbol will be permanently displayed the zone light on...

Страница 19: ...nect the neoHub to your router with the ethernet cable provided Connect the neoHub power supply also provided with the hub Download the neoApp and register your account Sign in to your account select...

Страница 20: ...y additional Neo s select the icon in the app then Add Thermostat The neoPlug is a compatible repeater for the neoAir V2 M when used with the neoHub UH8 RF RF Switch or RF Switch 16A The neoPlug is no...

Страница 21: ...Modes 1 3 Thermostat Thermostat with Hot Water 20 Air M neo...

Страница 22: ...5 10 12 13 15 17 14 16 18 9 6 1 2 3 4 8 7 11 21 Series neo...

Страница 23: ...Indicator Displayed during programming 6 level mode to show which period is being altered 10 Program Indicator Displayed during programming 4 level mode to show which period is being altered 11 Main M...

Страница 24: ...CLOCK Press to confirm selection Use Up Down keys to set the year Repeat the steps to set the Month Day Time Press to confirm the new clock settings Use the down arrow to scroll to highlight Press to...

Страница 25: ...neoAir has default comfort levels already programmed Each comfort level is a time temperature setting to maintain from that time onwards until the next level The default times and temperature settings...

Страница 26: ...erature Press the right arrow key LEAVE will now flash and the current settings will be displayed Press to alter LEAVE settings Repeat these steps to program all remaining comfort levels For any unuse...

Страница 27: ...hen you press either key you will see the word SET and the desired temperature value Use the Up Down keys to adjust the SET value Press to confirm settings and return to the main display Note This new...

Страница 28: ...Down keys to set the desired Hold period Use the Up Down keys to set the desired Hold temperature You will see the HOLD LEFT indication is displayed on screen The time will countdown the set duration...

Страница 29: ...d Hold period Use the Up Down keys to set the desired Hold temperature You will see the HOLD LEFT indication is displayed on screen The time will countdown the set duration and then revert to the norm...

Страница 30: ...et the boost duration e g 02 00 hours Press to confirm settings and return to main display To cancel a timer boost select HOLD on the main menu press once HEATING will now be highlighted use the left...

Страница 31: ...gits The display will return to the main screen and display the keypad lock indicator Note The touch key lock indicator is only displayed when the lock is active Unlocking the neoAir V2 M To unlock th...

Страница 32: ...temperature setting which as default is 12 C Frost Protection Standby Mode Frost Protection Mode Enabled 31 Series neo Use the Left arrow key to highlight on the menu Press once to enable frost protec...

Страница 33: ...lay heating output is now turned OFF To turn on the neoAir V2 M press once Thermostat completely OFF Thermostat powered ON 32 Air M neo To turn off the neoAir V2 M s display Use the Left arrow key to...

Страница 34: ...e timed output as OFF Set a date time for the holiday period to end using the steps below Use the Left Right keys to scroll to HOLIDAY and press Use the Up Down keys to set the year Use the Up Down ke...

Страница 35: ...put Delay To prevent rapid switching an output delay can be entered This can be set from 00 15 minutes The default is 00 which means there is no delay Feature 05 Temperature Up Down Limit This functio...

Страница 36: ...owing program mode options Weekday Weekend 4 comfort levels for Monday Friday 4 different comfort levels for Saturday Sunday 7 Day Program Each day of the week has 4 comfort levels that can be program...

Страница 37: ...firm settings and exit the setup menu Setting Value Feature Number 36 Air M neo Use the Left arrow key to highlight on the menu Press and hold for 3 seconds SETUP is now highlighted press once to ente...

Страница 38: ...emperature Format DESCRIPTION 00 Disabled 01 Enabled Default 00 99 Receiver address zone no type Commences countdown from 99 00 seconds Used to add zone to the neoHub neoHub Mini 00 5 0 5 C 01 1 0 C D...

Страница 39: ...perature reading follow these steps Press and hold and Down arrow keys together for 10 seconds The current temperature will appear on the display Use the Up Down keys to configure the new temperature...

Страница 40: ...rmostat Mode 2 Timer Use the Left arrow key to highlight on the menu Press and hold for 3 seconds SETUP is now highlighted press and hold for 10 seconds Until all icons appear 1 2 or 3 is shown in the...

Страница 41: ...Remote Sensor Probe Wiring 40 Air M neo...

Страница 42: ...Mode 2 Time Clock 7 8 9 10 11 5 1 2 3 4 6 Model Manual REF 41 41 Series neo...

Страница 43: ...mming to show which level is being altered 6 Main Menu Displays which option is currently selected 7 Keypad Lock Indicator Displayed when the keypad is locked 8 Battery Indicator Shown when batteries...

Страница 44: ...use the Up Down keys to set HOURS Press the Right arrow key The number 2 will now flash and the ON time will be displayed To confirm all changes use the Right key to select DONE and press Setting the...

Страница 45: ...e g 02 00 hours Press to confirm settings and return to main display Hold Left and the remaining time will now be displayed Timer Override HOLD LEFT Indicator Hold Time Remaining 44 Air M neo To canc...

Страница 46: ...e P3 Failsafe If the RF Switch or UH8 RF fails to receive a signal from the timeclock within 40 minute period it will activate to output for 12 minutes every hour The RF Switch UH8 RF will continue to...

Страница 47: ...00 99 Receiver address zone no type Commences countdown from 99 00 seconds Used to add zone to the neoHub P3 P2 P1 01 02 Failsafe Pairing to UH8 RF Pairing to RF Switch Pairing to Hub Program Mode 46...

Страница 48: ...69090 Or view technical specifications directly on our website www heatmiser com Heatmiser UK Ltd Units 1 5 Hurstwood Court Mercer Way Shadsworth Business Park Blackburn Lancashire BB1 2QU United King...