Feature 08 – Optimum Start:
Optimum start will delay the start-up of the heating system
to the latest possible moment to avoid unnecessary heating and ensure the building is
warm at the programmed time. The thermostat uses the rate of change information to
calculate how long the heating needs to raise the building temperature 1°C (with a rate
of change of 20, the thermostat has calculated the heating needs 20 minutes to raise the
building temperature 1°C) and starts the heating accordingly.
Feature 09 - Rate of Change:
Number of minutes for 1°C temperature rise.
Feature 10 –
Not used on this model.
Feature 11 –
Not used on this model.
Feature 12 – Program Mode:
The neoAir V2-M offers the following program mode options;
Weekday/ Weekend -
4 comfort levels for Monday - Friday.
4 different comfort levels for Saturday - Sunday.
7 Day Program -
Each day of the week has 4 comfort levels that can be
programmed independently.
24 Hour program -
All days of the week are programmed with the same levels.
Feature 13 -
Temperature Format:
This function allows you to select between °C and °F.
Feature P1 - Pairing:
to the RF-Switch, RF-Switch 16 Amp.
Feature P2 - Setting the UH8-RF address:
This is the number set on the rotary dials inside
the UH8-RF unit, the zone number & zone type.
Feature P3 - Failsafe:
If the receiver fails to receive a signal from the neoAir V2-M within a 40
minute period, it will activate the output for 12 minutes every hour.
The receiver will continue to do this until it receives a signal from the neoAir V2-M.
35
Series
neo
Non-programmable -
Simple up/down temperature control, no timing.
Содержание NeoAir V2-M
Страница 1: ...Air M neo...
Страница 2: ...1 Model Series Air M neo neo...
Страница 5: ...4 Air M neo 1 2 3 4...
Страница 10: ...9 Series neo RF Switch Page 12 RF Switch 16 Amp Page 13 neoHub Mini OT Page 14 15 neoHub Mini HW Page 16 17...
Страница 21: ...Modes 1 3 Thermostat Thermostat with Hot Water 20 Air M neo...
Страница 22: ...5 10 12 13 15 17 14 16 18 9 6 1 2 3 4 8 7 11 21 Series neo...
Страница 41: ...Remote Sensor Probe Wiring 40 Air M neo...
Страница 42: ...Mode 2 Time Clock 7 8 9 10 11 5 1 2 3 4 6 Model Manual REF 41 41 Series neo...