Heatizon  Systems  GutterMelt

®

  SR    rain  gutter,  eaves  trough,  downspout,  and  eave 

deicing  systems  provide  heat  to  maintain  water  flow  paths  on  eaves,  and  in  gutters, 
downspouts  and  drains.    This  heating  cable  is  placed  directly  on  top  of  the  roofing 
material  and/or  in  the  rain  gutter,  downspouts  and  drains  of  a  building.  Heatizon 
Systems products can be activated by a large variety of activation alternatives ranging 
from a simple switch to an automatic temperature moisture sensor. 

ADVANTAGES 

  Prevents costly damage to roofs, gutters and downspout drains by providing a path for water to exit 

  May be applied anywhere snow or ice can accumulate 

  May be used on all types of standard roof covering material 

  May be installed in rain gutters and downspouts made of metal, plastic, etc 

  Industry leading warranty - designed for reliability 

  GutterMelt

®

 SR is available in 5, 9, and 12 Watts/ft. Special orders deliver up to 24 Watts per foot at 32

°

F in iced water 

  Field cut to length 

• 

Many activation options including temperature/moisture sensors 

• 

Finest quality SR cable available 

FAST & EASY INSTALLATION 

Heatizon  Systems  GutterMelt

®

  SR  system  utilizes  easy  to  install 

SR  cable  to  provide  reliable  freeze  protection  of  roofs,  gutters, 
downspouts  and  roof  drains.    Simply  run  the  cable  in  gutters 
using  foil  tape  with  pressure  sensitive  adhesive  to  secure  cable 
placement,  or  Heatizon  roof  clips  (Heatizon  Part  #HT386530  or 
#HT386530R).  Roof  clips  attach  the  cable  to  standard  roof 
covering  material.  The cable can also be inserted in downspouts 
using  downspout  hangers  or  brackets  (Heatizon  Part  #HT38411 
or  #HT386412)  to  support  the  heating  cable.  GutterMelt

® 

SR 

cable  may  be  cut  to  length  in  the  field  making  installation  easy 
and convenient. 

VALUE 

Winter has many freeze thaw cycles that can cause millions of dollars 
of  damage  to  roofs,  gutters,  downspouts,  and  drains  every  year.  As 
winter  progresses buildings experience  ice  buildup  which  can lead to 
roof damage, or damage caused by snow and ice falling from the roof. 
These  cycles  can  cause  ice  to  accumulate  and  back  up  under 
shingles, resulting in ice dams. In some cases, damage appears in the 
form of soaked insulation, stained, cracked and damaged sheet rock, 
damp,  smelly,  rotting  wall  cavities  and  stained,  blistered  and  peeling 
paint. Heatizon Systems has the products and expertise to effectively 
solve  potential  winter  issues  and    protect  your  investment  by 
managing  ice  dams,  minimizing  icicles,  and  keeping  ice  from 
accumulating in gutters and downspouts. 
 
What GutterMelt won’t do? 

• 

Prevent snow movement on/off the roof 

• 

Remove  accumulated  snow  and  ice  from  roofs,  gutters  and 
downspouts 

 

  Gutters      

  Downspouts    

  Roof Eaves  

 

ENERGY EFFICIENT AND COST EFFECTIVE  

GutterMelt

®

 SR is 100% efficient and automatically adjusts its heat output and energy consumption as the temperature conditions 

change.  When precipitation is expected, simply energize the cable.  The cable  provides  maximum melting power when snow or 
ice is present, but will automatically regulate its output and save energy when the roof and gutters are clear of snow and ice.   

 

Содержание Gutter Melt SR

Страница 1: ...www heatizon com 2017 Heatizon Systems HEATIZON SYSTEMS RADIANT HEATING AND SNOW MELTING SYSTEMS GutterMelt SR is a registered trademark of Heatizon Systems 07 17...

Страница 2: ...2...

Страница 3: ...minders 6 GutterMelt SR Cable Layout Design Guidelines 7 GutterMelt Accessories 9 GutterMelt Activation 11 Design and Installation 13 Resistance Recording Page 18 Warranty 19 Note Before proceeding wi...

Страница 4: ...ach the cable to standard roof covering material The cable can also be inserted in downspouts using downspout hangers or brackets Heatizon Part HT38411 or HT386412 to support the heating cable GutterM...

Страница 5: ...Electrical Code CEC part 1 and local codes and regulations Note Ground fault protection must be used when installing all GutterMelt SR products Refer to the NEC or CEC for specific requirements Note D...

Страница 6: ...ed to a suitable earth ground Do not exceed the maximum circuit lengths listed in this Design and Installation Manual Always remember to test the insulation resitance using a 2500 VDC Megohmmeter veri...

Страница 7: ...R are attached with a screw or nail GutterMelt cable is installed then a water sealing caulking is applied around the clips screws and nails to prevent leaks Sloped Roof with Gutter and a Valley Exten...

Страница 8: ...rMelt in down spout or drain to prevent damage to cable Downspouts A continuous path for melt water can be maintained by running the Gut terMelt inside the downspout to the bottom and extend a small d...

Страница 9: ...n GutterMelt is secured to angled bracket no fasteners required Includes UV resistant plastic wire ties Includes two 2 downspout hanger bracket assemblies Prevents heating cable from being damaged at...

Страница 10: ...C or 300 feet 5W 120VAC GutterMelt SR Cable Contains GFCI with 30mA test and reset Power ON indicator light Requires NEMA5 20 Amp Outlet Receptacle HT393473 PT 15 Amp 120VAC Plug in Pig Tail Set Used...

Страница 11: ...Mounted Sensor One 30A Contact Activates System when moisture is detected and temperature is below set point Leaves system on for up to 6 hours Requires 100 277VAC Switches up to one 30A Loads M326CD...

Страница 12: ...ion device Provides two different delay features Powered by 12VDC provides 24VAC for activation device as well as up to 12 circuits of monitoring M332 Gutter Controller Gutter Controller allows Heatiz...

Страница 13: ...erMelt SR is designed for snow melt applications and to provide a path for water to exit the roof gutter and downspout drain STEP 1 PLAN THE LAYOUT Note Make certain to plan for the movement of the wa...

Страница 14: ...started at 40 F 0 F 20 F 505 475 420 650 560 765 765 9GM1 If started at 40 F 0 F 20 F 320 210 185 425 270 245 455 405 370 460 460 12GM1 If started at 40 F 0 F 20 F 240 155 135 315 210 180 375 310 270...

Страница 15: ...tivators require human action as a result they should be placed in a location that is convenient and easily accessible STEP 6 LOCATION SELECTION STEP 3 CONTACT YOUR GUTTERMELT SR SUPPLIER Contact your...

Страница 16: ...chased from your Heatizon Systems Distributor to attach GutterMelt SR to the roof covering material Use Foil Tape purchased from your Heatizon Systems Distributor to attached GutterMelt SR to the rain...

Страница 17: ...of 20 MegOhms between the heating element and the braided shield STEP 12 COMPLETE AND ATTACH LABELS STEP 11 TROUBLESHOOTING Problem GutterMelt SR Cable fails the Megohmmeter Test Potential Causes Chec...

Страница 18: ...00 VDC at least twice The measured value should not be less than 20 Megohms Record all test results below Prior to Installation When removed from Package After Installation of GutteMelt SR Heating Ele...