GUTTERMELT

®

 ACTIVATION  

 

Part Number   

Product 

 

Usage Description 

 

M330 Relay 
Panel Series 

 

Heatizon Relay Panel 

30A & 50A 

 

Heatizon Relay Panel requires 120V, for  

120/208/240/277/480 VAC; Also accepts 

activation devices that switch 12V DC.  
Contains four relays, master rocker switch, and 
four auto/manual area rocker switches.  M330 
switches up to four 30AMP loads.  M330-50 
switches up to four 50AMP loads.   M330-G 
Model includes GFEP. 

 

M330G Relay 
Panel Series 

 

Heatizon Relay Panel 

30A & 40A with GFEP  

 

Heatizon Relay Panel requires 120V, for 

120/208/240/277/480 VAC; Contains four 

relays, master rocker switch, and four auto/
manual area rocker switches.  M330-G 
switches up to four 30AMP loads.  M330G-40 
switches up to four 40AMP FLA loads. Both 
include GFEP.  

 

M530 Series 

 

Heatizon Contactor 
Panel 50A with and 

without GFEP  

 

The M530 Contactor Panel Series can control 
1-8 circuits at 208/240/480 VAC, or 1-16 circuits 
at 120/277/600 VAC and is compatible with 
many Heatizon activation devices. The M530 
do not include GFEP. 

 

M346 

 

Heatizon Monitor  

Station Selector Box 

 

Allows up to 12 zones/panels to be activated 
and monitored by one activation device.  
Provides two different delay features.  Powered 
by 12VDC, provides 24VAC for activation 
device as well as up to 12 circuits of monitoring. 

 

M332 

  Gutter Controller 

 

 

Gutter Controller  allows Heatizon Systems Line 
Voltage Cables to be turned on and off 
whenever a Tuff Cable or ZMesh system is 
turned on and off. Designed to fit over a 
standard electrical outlet box.   Switches 
120/208/240/277 VAC. 

 

M435 

 

Roof, Gutter and Pipe 

Moisture     

Sensor,  Outdoor 

Temperature Sensor 

and Controller.  

 

Gutter/Roof Deicing with Moisture Sensor,  
Outdoor Temperature Sensor and Controller. 
Designed to lay in gutters or hang in  
downspouts and pipes. The moisture sensor 
detects moisture while the outdoor temperature 
sensor monitors ambient temperature. Included 
up to 2 zones and 3 output relays with 16A load 
switch capability. 

 

M515/M515G 

 

Temp Control J-Box 

120/277VA 

  

 

Activates System when temperature is below 
set point. 0° - 50° F : Temperature Selection  
5° F Temperature Differential. Automatic 
Activation for reliable system operation. 
Switches 120/277 VAC 50/60hz. FLA 20A 
@120VAC - FLA 16A @277VAC. 

 

M516/M516G 

 

Temp Control J-Box 

208/240VAC 

 

Activates System when temperature is below 
set point. 0° - 50° F : Temperature Selection  
5° F Temperature Differential. Automatic 
Activation for reliable system operation. 
Switches 208/240 VAC. 30A @208VAC - 30A 
@240VAC 

Содержание Gutter Melt SR

Страница 1: ...www heatizon com 2017 Heatizon Systems HEATIZON SYSTEMS RADIANT HEATING AND SNOW MELTING SYSTEMS GutterMelt SR is a registered trademark of Heatizon Systems 07 17...

Страница 2: ...2...

Страница 3: ...minders 6 GutterMelt SR Cable Layout Design Guidelines 7 GutterMelt Accessories 9 GutterMelt Activation 11 Design and Installation 13 Resistance Recording Page 18 Warranty 19 Note Before proceeding wi...

Страница 4: ...ach the cable to standard roof covering material The cable can also be inserted in downspouts using downspout hangers or brackets Heatizon Part HT38411 or HT386412 to support the heating cable GutterM...

Страница 5: ...Electrical Code CEC part 1 and local codes and regulations Note Ground fault protection must be used when installing all GutterMelt SR products Refer to the NEC or CEC for specific requirements Note D...

Страница 6: ...ed to a suitable earth ground Do not exceed the maximum circuit lengths listed in this Design and Installation Manual Always remember to test the insulation resitance using a 2500 VDC Megohmmeter veri...

Страница 7: ...R are attached with a screw or nail GutterMelt cable is installed then a water sealing caulking is applied around the clips screws and nails to prevent leaks Sloped Roof with Gutter and a Valley Exten...

Страница 8: ...rMelt in down spout or drain to prevent damage to cable Downspouts A continuous path for melt water can be maintained by running the Gut terMelt inside the downspout to the bottom and extend a small d...

Страница 9: ...n GutterMelt is secured to angled bracket no fasteners required Includes UV resistant plastic wire ties Includes two 2 downspout hanger bracket assemblies Prevents heating cable from being damaged at...

Страница 10: ...C or 300 feet 5W 120VAC GutterMelt SR Cable Contains GFCI with 30mA test and reset Power ON indicator light Requires NEMA5 20 Amp Outlet Receptacle HT393473 PT 15 Amp 120VAC Plug in Pig Tail Set Used...

Страница 11: ...Mounted Sensor One 30A Contact Activates System when moisture is detected and temperature is below set point Leaves system on for up to 6 hours Requires 100 277VAC Switches up to one 30A Loads M326CD...

Страница 12: ...ion device Provides two different delay features Powered by 12VDC provides 24VAC for activation device as well as up to 12 circuits of monitoring M332 Gutter Controller Gutter Controller allows Heatiz...

Страница 13: ...erMelt SR is designed for snow melt applications and to provide a path for water to exit the roof gutter and downspout drain STEP 1 PLAN THE LAYOUT Note Make certain to plan for the movement of the wa...

Страница 14: ...started at 40 F 0 F 20 F 505 475 420 650 560 765 765 9GM1 If started at 40 F 0 F 20 F 320 210 185 425 270 245 455 405 370 460 460 12GM1 If started at 40 F 0 F 20 F 240 155 135 315 210 180 375 310 270...

Страница 15: ...tivators require human action as a result they should be placed in a location that is convenient and easily accessible STEP 6 LOCATION SELECTION STEP 3 CONTACT YOUR GUTTERMELT SR SUPPLIER Contact your...

Страница 16: ...chased from your Heatizon Systems Distributor to attach GutterMelt SR to the roof covering material Use Foil Tape purchased from your Heatizon Systems Distributor to attached GutterMelt SR to the rain...

Страница 17: ...of 20 MegOhms between the heating element and the braided shield STEP 12 COMPLETE AND ATTACH LABELS STEP 11 TROUBLESHOOTING Problem GutterMelt SR Cable fails the Megohmmeter Test Potential Causes Chec...

Страница 18: ...00 VDC at least twice The measured value should not be less than 20 Megohms Record all test results below Prior to Installation When removed from Package After Installation of GutteMelt SR Heating Ele...

Страница 19: ...urchased from Heatizon Systems integrated into or connected to them 4 Any labor costs for removal of alleged defective part s and or reinstallation of replacement part s transportation to and from Hea...

Страница 20: ...20 Mail Heatizon Systems 4137 South 500 West Murray UT 84123 USA Phone 801 293 1232 Toll Free 888 239 1232 Fax 801 293 3077 Email info heatizon com Website www heatizon com...