background image

 

GUTTERMELT

®

 ACCESSORIES  

 

Part Number   

Product 

 

Usage/Description 

 

HT386530 

 

Roof Clips, 

Steel 

 

  Use to attach GutterMelt

®  

heating cable to roof surface 

  Five (5) Double or ten (10) Single Clips per package 

  Accommodate approximately 7 linear feet of  GutterMelt

®     

      

cable 

  Attached with a mechanical fastener or approved adhesive  

    sealant 

 

HT386530R 

 

Roof Clips,  

Aluminum 

 

  Use to attach GutterMelt

®  

heating cable to roof surface. 

  HT386530R includes 10 clips—enough for approximately  

    7 eave feet of GutterMelt

®  

cable 

  Attached with a mechanical fastener or approved adhesive  

    sealant 

 

HT386411 
 

 

Downspout 

Hanger Kit 

 

 Use to suspend GutterMelt

®  

heating cable in a gutter,   

   downspout or drain 

 Attached with a mechanical fastener  

 Includes three (3) downspout hanger assemblies 

 Prevents heating cable from being damaged at gutter-to-     

   downspout and other transition points 

 

HT386412 

 

Downspout 

Hanger Bracket 

Kit 

 

 Used to suspend GutterMelt

®  

in downspout or drain 

 GutterMelt

® 

 

is secured to angled bracket; no fasteners           

 

   required 

 Includes UV resistant plastic wire ties 

 Includes two (2) downspout hanger bracket assemblies 

 Prevents heating cable from being damaged at gutter-to-     

   downspout and other transition points 

 

HT386521M 

 

End Seal Kit 

 

 Use to terminate and seal the non-powered ends of           

   GutterMelt

®  

heating cable 

 Materials for three (3) end seals 

 Provides water resistant seal 

 

HT386505M 

 

Power  

Connect Kit 

 

•  

Use to terminate one powered end of GutterMelt

®  

heating  

   cable into a junction box and to seal off one non-powered  
   end of cable 

•  

Used for a hard-wired connection to supply power 

•  

Includes materials for one (1) power connection assembly 

•  

Includes one (1) end seal for non-powered cable end 

 

 
HT386513 

 

Splice Kit 

 

•  

Connect two heating cables together  

•  

Creates a water-resistant connection 

•  

Spice Kit contains materials for two (2) splice connections 

 

 
HT386513T 

 

Tee Kit 

 

•  

Connect heating cables together to make a tee connection 

•  

Creates a water-resistant connection 

•  

Tee Kit contains materials for four (1) Tee connection 

•  

Includes one (1) end seal for non-powered cable end 

•  

Includes sealant and wire ties 

Содержание Gutter Melt SR

Страница 1: ...www heatizon com 2017 Heatizon Systems HEATIZON SYSTEMS RADIANT HEATING AND SNOW MELTING SYSTEMS GutterMelt SR is a registered trademark of Heatizon Systems 07 17...

Страница 2: ...2...

Страница 3: ...minders 6 GutterMelt SR Cable Layout Design Guidelines 7 GutterMelt Accessories 9 GutterMelt Activation 11 Design and Installation 13 Resistance Recording Page 18 Warranty 19 Note Before proceeding wi...

Страница 4: ...ach the cable to standard roof covering material The cable can also be inserted in downspouts using downspout hangers or brackets Heatizon Part HT38411 or HT386412 to support the heating cable GutterM...

Страница 5: ...Electrical Code CEC part 1 and local codes and regulations Note Ground fault protection must be used when installing all GutterMelt SR products Refer to the NEC or CEC for specific requirements Note D...

Страница 6: ...ed to a suitable earth ground Do not exceed the maximum circuit lengths listed in this Design and Installation Manual Always remember to test the insulation resitance using a 2500 VDC Megohmmeter veri...

Страница 7: ...R are attached with a screw or nail GutterMelt cable is installed then a water sealing caulking is applied around the clips screws and nails to prevent leaks Sloped Roof with Gutter and a Valley Exten...

Страница 8: ...rMelt in down spout or drain to prevent damage to cable Downspouts A continuous path for melt water can be maintained by running the Gut terMelt inside the downspout to the bottom and extend a small d...

Страница 9: ...n GutterMelt is secured to angled bracket no fasteners required Includes UV resistant plastic wire ties Includes two 2 downspout hanger bracket assemblies Prevents heating cable from being damaged at...

Страница 10: ...C or 300 feet 5W 120VAC GutterMelt SR Cable Contains GFCI with 30mA test and reset Power ON indicator light Requires NEMA5 20 Amp Outlet Receptacle HT393473 PT 15 Amp 120VAC Plug in Pig Tail Set Used...

Страница 11: ...Mounted Sensor One 30A Contact Activates System when moisture is detected and temperature is below set point Leaves system on for up to 6 hours Requires 100 277VAC Switches up to one 30A Loads M326CD...

Страница 12: ...ion device Provides two different delay features Powered by 12VDC provides 24VAC for activation device as well as up to 12 circuits of monitoring M332 Gutter Controller Gutter Controller allows Heatiz...

Страница 13: ...erMelt SR is designed for snow melt applications and to provide a path for water to exit the roof gutter and downspout drain STEP 1 PLAN THE LAYOUT Note Make certain to plan for the movement of the wa...

Страница 14: ...started at 40 F 0 F 20 F 505 475 420 650 560 765 765 9GM1 If started at 40 F 0 F 20 F 320 210 185 425 270 245 455 405 370 460 460 12GM1 If started at 40 F 0 F 20 F 240 155 135 315 210 180 375 310 270...

Страница 15: ...tivators require human action as a result they should be placed in a location that is convenient and easily accessible STEP 6 LOCATION SELECTION STEP 3 CONTACT YOUR GUTTERMELT SR SUPPLIER Contact your...

Страница 16: ...chased from your Heatizon Systems Distributor to attach GutterMelt SR to the roof covering material Use Foil Tape purchased from your Heatizon Systems Distributor to attached GutterMelt SR to the rain...

Страница 17: ...of 20 MegOhms between the heating element and the braided shield STEP 12 COMPLETE AND ATTACH LABELS STEP 11 TROUBLESHOOTING Problem GutterMelt SR Cable fails the Megohmmeter Test Potential Causes Chec...

Страница 18: ...00 VDC at least twice The measured value should not be less than 20 Megohms Record all test results below Prior to Installation When removed from Package After Installation of GutteMelt SR Heating Ele...

Страница 19: ...urchased from Heatizon Systems integrated into or connected to them 4 Any labor costs for removal of alleged defective part s and or reinstallation of replacement part s transportation to and from Hea...

Страница 20: ...20 Mail Heatizon Systems 4137 South 500 West Murray UT 84123 USA Phone 801 293 1232 Toll Free 888 239 1232 Fax 801 293 3077 Email info heatizon com Website www heatizon com...

Отзывы: