30532 Rev D
20
09-02
NASIM REAR DIRECT VENT DECORATIVE GAS APPLIANCE
4. WIRING
Standing Pilot Ignition - Millivolt System
a. Appliance Requirements.
A wiring diagram is
shown in Figure 39.
b. Optional Accessories Requirements.
Wiring for
optional accessories should be done now to avoid
reconstruction.
Note:
This appliance must be electrically wired and
grounded in accordance with local codes. In the absence
of local codes, the wiring must comply with the National
Electric Code ANSI/NFPA 70 - latest edition or the
Canadian Electric Code, CSA C22.1.
WARNING!
This standing pilot appliance does not require a 110V AC power supply
for operation. Connecting the appliance/wall switch to a 110V AC will
cause the appliance to malfunction and destroy the valve and
thermopile.
Figure 39
Standing Pilot Ignition Wiring Diagram
14-3 with Ground Romex is the recommended
wiring to the appliance junction box.
Detailed picture of the junction box
(optional for standing pilot appliances).
Break the tab between
the two hot connectors.