NASIM REAR DIRECT VENT DECORATIVE GAS APPLIANCE
3. VERTICAL TERMINATION
a. Clearances
See Figure 15 for clearance information.
b. Vent Lengths
Various venting configurations are shown in Figure
16 and 17 from which the maximum vent runs can
be determined.
Figure 15
Vent Clearances
Figure 16 - Vent Lengths
Figure 17
Vent Support
WARNING!
A gas appliance must not be connected to a chim-
ney flue servicing a separate solid fuel burning ap-
pliance.
WARNING - RISK OF FIRE!
Always maintain minimum clearances or greater
around the chimney system. Do not pack air spaces
with insulation or other material.
WARNING!
The horizontal run of vent must have a 1/4 rise for
every 1 ft. of run towards the termination. Never al-
low the vent to run downward. This could cause high
temperatures and present a fire hazard.
Starter elbows cannot
be used in any rear
venting configuration.
Starter elbows
cannot be used
in any rear
venting
configuration.
Starter elbows
cannot be used in
any rear venting
configuration.