7
December 9, 2019
7059-801D
HEATILATOR ECO CHOICE PS50
Model
PS50-C
Laboratory
Intertek
Safety
Report No.
4001508
Type
Solid Fuel Room Heater/Pellet Fuel
Burning Type
Standard
ASTM E1509-04 and ULC S627-00
Room Appliance Pellet Fuel Burning
type and (UM) 84-HUD, Mobile
Home Approved.
B. BTU & Efficiency Specifications
1
Listing and Code Approvals
A. Appliance Certification
NOTICE:
This installation must conform with local codes. In the absence of local codes you must comply with the
ASTM E1509-04, ULC S627-00, and (UM) 84-HUD
.
Laboratory:
OMNI Test Laboratories, Inc.
Emissions Report #:
0061PS085E
EPA Certified
Emissions:
1.0 grams/hour
*LHV Tested Efficiency:
69.5%
**HHV Tested Efficiency:
65.1%
***EPA BTU Output:
7,500 to 36,600 per hr.
****BTU Input:
13,100 to 49,900 per hr.
Vent Size:
3 or 4 inches, “L” or “PL”
Hopper Capacity:
83 bs.
Fuel
Premium Wood Pellets
*Weighted average LHV (Low Heating Value) efficiency
using data collected during EPA emissions tests..
**Weighted average HHV (High Heating Value) efficiency
using data collected during EPA emissions tests.
***A range of BTU outputs calculated using HHV
efficiency and the burn rates from the EPA tests.
****Based on the maximum feed rate per hour multiplied
by approximately 8600 BTU’s which is the average BTU’s
from a pound of pellets.
‡ Grade of pellet fuel as certified by Pellet Fuels Institute (PFI), ENPlus
or CANplus.
This pellet heater needs periodic inspection and repair for proper operation. It is against federal regulations to operate this
pellet heater in a manner inconsistent with operating instructions in this manual.
The PS50 is Certified to
comply with 2020 particulate
emission standards.