28
December 9, 2019
7059-801D
HEATILATOR ECO CHOICE PS50
6
Reference Materials
2. Convection Blower
The convection blower is mounted at the bottom rear of the
appliance. There are 2 impellers, one on each side of the
motor. The convection blower pushes heated air through
the heat exchange system into the room.
3. Exhaust Blower
The exhaust blower is mounted on the right side of the
appliance. The exhaust blower is designed to pull the
exhaust from the appliance and push it out through the
venting system.
4. Feed System
The feed system is located on the right side of the
appliance and can be removed as an entire assembly.
The assembly includes the feed motor, mounting bracket,
bearing and feed spring (auger). The hollow feed spring
(auger) pulls pellets up the feed tube from the hopper area
and drops them down the feed chute into the fire pot.
5. Fire pot
The fire pot is made of high quality ductile iron and has
a cleaning pull-out rod. The floor of the fire pot opens for
cleaning when you pull out the rod. Be sure that the floor
returns to a completely closed position or your appliance
will not operate properly.
6. Fuse
The fuse is located on the side of the junction box above
to the red call light. The fuse will blow should a short occur
and shut off power to the appliance.
7. Heat Output Switch
The heat output switch is located on the upper right back
panel. The function of the heat output switch is to regulate
the burn rates; low, medium and high settings.
8. Hopper Switch
The hopper switch is located in the upper right hand corner
of the hopper. This switch is designed to shut down the
feed motor whenever the hopper lid is opened.
9. Igniter
The igniter is mounted on the base of the fire pot.
Combustion air travels over the red hot igniter creating
super heated air that ignites the pellets.
10. Junction Box And Wiring Harness
The junction box is located on the lower left side of the
appliance, behind the left side panel. The junction box and
wiring harness are replaced as one component.
When describing the location of a
component, it is always AS YOU FACE THE
FRONT OF THE APPLIANCE.
A. Component Functions
1. Control Box
a. The control box is located on the lower left side of
the appliance, behind the lower left side panel and
above the junction box.
b. There is a light located inside of the control box.
The internal light will turn green when the appliance
has reached a temperature of 200°F (93°C) in the
fire pot. and will turn red when it reaches 600°F
(315°C).
c. There is also an internal blue light located in the
control box. When you plug in the appliance the
blue light will automatically start blinking. This
model it should blink 2 times.
To set your control board on the correct number:
• Unplug the appliance.
•
Using #2 Phillips screw driver, 3/8” wrench, or 3/8”
socket loosen the three screws that hold the right upper
and lower side panels in place. You do not need to
remove the screws. Remove side panels by lifting up
and out.
•
Use a #2 Phillips screw driver to remove the control
box retainer bracket and lift control box out of the
junction box.
•
Using a ¼ inch flat head screw driver turn the rotary
switch until the desired number is showing on the dial.
• Re install control box and plug in appliance.
•
To confirm your selection is correct count the number of
times the blue light flashes.
Example:
If you are on setting 2 the control box will flash 2
times every 10 seconds for 1 minute.
Your PS50 is set to #2 (2 flashes)
(Figure 28.1)
.
NOTE:
Do NOT open the control box. This will void the
warranty. If you need to plug in or remove the
control box you must first unplug the appliance.
Figure 28.1 - Rotary Switch