Heatilator Eco Choice PS50 Скачать руководство пользователя страница 11

11

December 9, 2019

7059-801D

HEATILATOR ECO CHOICE PS50

G. Hopper Lid Latch and Hopper Switch

1. 

Lift up the hopper lid and lock into open position.  Now 

you can fill the hopper with fuel.

2.  The hopper switch is designed to shut down the feed 

motor when the hopper lid is open. Leaving the lid open 

too long can cause the fire to go out 

(Figure 11.1)

.

3.  To close the hopper lid, while holding lid open with one 

hand, push the bottom of the latch inwards to release 

from locked position and then slowly close the hopper 

lid

 (Figure 11.2)

.

Figure 11.1

Figure 11.2

Hopper Lid Latch

Hopper Switch

Push Bottom of Latch 

Inward to Release

H. Starting Your First Fire

1.  A thermostat is required for proper operation of this 

appliance. If you have to adjust the feed rate after 

you have started the fire, most of the pellets in the 

hopper will need to be removed so start out with filling 

the hopper approximately 1/4 full at this time.  Set the 

thermostat to its lowest setting and plug the power cord 

into nearby outlet.

2.  The exhaust blower will stay on for approximately 18 

minutes even though the thermostat is not calling for 

heat. This is normal.

3. 

Locate the heat output control switch mounted on 

the back of the appliance in the upper left corner 

(Figure 8.1 on page 8)

.

4. 

Turn it to the “high” setting by pushing the top of the 

control switch in and then adjust the thermostat to its 

highest setting.

5.  Look through the hole in the left lower side panel and 

you will see the red call light on the control box will 

be on

 (Figure 11.3)

. This indicates the thermostat is 

calling for heat. 

6.  The fuel feed system and the igniter should now be on.

7. 

For your first fire it will be necessary to press the reset 

button once approximately 2 minutes after start up 

and again in 5 minutes. Reset as needed or every 60 

seconds until pellets begin to drop into fire pot. This will 

fill the feed system and allow the appliance to begin 

dropping pellets. Or you can put a handful of pellets 

in the fire pot to speed up the process. The appliance 

will continue to run as long as the thermostat is calling 

for heat.

8. 

Once the appliance has ignited, let it burn for 

approximately 15 minutes, then set the thermostat to 

the desired room temperature. Adjust the heat output 

control switch to the desired setting. 

Figure 11.3

Control Box

Junction Box

Red Call Light

Fuse

Convection 

Blower

LOCATED BEHIND LEFT SIDE PANELS

Odors and vapors released during initial operation.

•  Curing of high temperature paint.

• 

Open windows for air circulation.

Odors may be irritating to sensitive individuals.

CAUTION

Содержание Eco Choice PS50

Страница 1: ...gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance Do not over fire If appliance or chimney connector glows you are over firing Over firing will void your w...

Страница 2: ...au dessus de la temp rature de la pi ce le po le s allumera automatiquement Pour teindre descendre la temp rature du thermostat en dessous de la temp rature de la pi ce Pour des instructions suppl me...

Страница 3: ...cedure 15 B Quick Reference Maintenance Chart 15 C General Maintenance 16 D High Ash Fuel Content Maintenance 20 E Soot or Creosote Fire 20 4 Troubleshooting Guide 21 5 Service Parts Replacement 24 A...

Страница 4: ...the verified purchase price of the product itself The maximum amount recoverable under this warranty is limited to the purchaser price of the product This warranty is subject to conditions exclusions...

Страница 5: ...caused by tightly sealed constructions insufficient make up air supply or handling devices such as exhaust fans or forced air furnaces or other such causes 6 use of fuels other than those specified in...

Страница 6: ...er cord into the wall receptacle Turn the thermostat on Turn the thermostat to off If the feed tube is empty or this is the first fire add a handful of pellets to the firepot Do not add extra fuel to...

Страница 7: ...per hr BTU Input 13 100 to 49 900 per hr Vent Size 3 or 4 inches L or PL Hopper Capacity 83 bs Fuel Premium Wood Pellets Weighted average LHV Low Heating Value efficiency using data collected during...

Страница 8: ...cts of combustion of such fuels can expose you to chemicals including carbon black which is known to the State of California to cause cancer and carbon monoxide which is known to the State of Californ...

Страница 9: ...aterial which will not ignite and burn composed of any combination of the following Steel Plaster Brick Iron Concrete Tile Glass Slate Materials reported as passing ASTM E 136 Standard Test Method for...

Страница 10: ...inal sealed bag until using to prevent moisture absorption This will also prevent rodents from becoming a problem Do not store any pellet fuel within the clearance requirements or in an area that woul...

Страница 11: ...ted on the back of the appliance in the upper left corner Figure 8 1 on page 8 4 Turn it to the high setting by pushing the top of the control switch in and then adjust the thermostat to its highest s...

Страница 12: ...me height or push down to decrease the feed rate and flame height 3 Re tighten the thumb screw A new stove has a break in period The fire characteristics should be checked again after 5 bags of pellet...

Страница 13: ...The appliance comes standard with a wall thermostat and 25 of wire If you need to run more than 25 make sure you use a continuous strand of 18 to 22 gauge thermostat wire For optimum performance your...

Страница 14: ...irty over time See General Maintenance Cleaning under Maintaining Servicing Appliance in the owner s manual No form of lubrication should ever need applied to the blowers Why are different components...

Страница 15: ...f trouble free service Contact your dealer to answer question regarding proper operation troubleshooting and service for your appliance Visit www heatilatorecochoice com Customer Care to view basic tr...

Страница 16: ...s built up on the bottom plate of the firepot and to push out any clinkers while in the open position d To close the firepot floor slightly raise the cleaning rod and then push it back into place If y...

Страница 17: ...haust Path Baffles Drop Tube Frequency Monthly or every 25 bags or more frequently depending on ash build up By Homeowner a Appliance must be completely cool b Open the door and remove the center baff...

Страница 18: ...to make sure there is a good seal Check door handle for smooth cam operation 10 Cleaning the Glass Frequency When clear view of the fire pot becomes obscure By Homeowner a Appliance must be completely...

Страница 19: ...ower Requires No Lubrication Frequency Yearly or more frequently depending on Dust Dirt build up By Homeowner or Qualified Service Technician a Be sure the appliance is allowed to cool and has been un...

Страница 20: ...blish a routine for the fuel wood burner and firing technique Check daily for creosote build up until experience shows how often you need to clean to be safe Be aware that the hotter the fire the less...

Страница 21: ...Make sure front door is closed Replace control box Call light on No fire Partially burned fuel in fire pot Fire pot clean out plate not closed Fire pot is dirty missed ignition Check that fire pot cle...

Страница 22: ...sing loss of vacuum Empty hopper of fuel Use a wet dry vacuum cleaner to remove remaining fuel from hopper including feed tube Check feed chute for obstructions Loosen 2 screws and jiggle feed assembl...

Страница 23: ...system Remove stainless steel baffle from firebox to clean ash from on top of baffle Clean behind rear brick panels Change fuel brand to premium Check that fire pot clean out plate is fully closed Red...

Страница 24: ...ance Figure 24 2 6 Release blower wires from the nylon wire retainer if applicable This appliance has 1 black and 1 white wire coming from the blower 7 Remove the wing bolt and move the blower and hol...

Страница 25: ...e install in reverse Snap Disc 2 Fuel Delivery Interrupt 1 Turn down thermostat let appliance cool completely if running Then unplug appliance before servicing 2 Using 2 Phillips screwdriver 3 8 wrenc...

Страница 26: ...l the ash drawer and side panel and re connect the power E Baffle Removal Replace 1 Shut down the appliance by turning down the thermostat and let the appliance completely cool down 2 Remove the cente...

Страница 27: ...ad screw driver remove the 4 brackets and set aside Figure 27 1 3 Remove old glass and replace with the new glass 4 Re install the brackets using the same screws Glass Assembly 1 2 3 4 Remove the 4 br...

Страница 28: ...ustion air travels over the red hot igniter creating super heated air that ignites the pellets 10 Junction Box And Wiring Harness The junction box is located on the lower left side of the appliance be...

Страница 29: ...7 Snap Disc 2 Fuel Delivery Interrupt 175 F Snap disc 2 is located on the center of the convection plenum above the convection blower There is an orange and a black wire connected to it This snap disc...

Страница 30: ...on Blower LOCATED BEHIND LEFT SIDE PANELS Control Box Junction Box Red Call Light Fuse LOCATED BEHIND RIGHT SIDE PANELS Feed Motor Vacuum Switch Combustion Blower Power Outlet Terminal Block Center 2...

Страница 31: ...31 December 9 2019 7059 801D HEATILATOR ECO CHOICE PS50 C Maintenance and Service Log Date of Service Performed By Description of Service...

Страница 32: ...rvice Parts Beginning Manufacturing Date Mar 2019 Ending Manufacturing Date Active PS50 C Part number list on following page Free Standing Pellet Stove 12 19 1 2 4 5 6 7 3 8 9 10 14 15 16 12 13 11 17...

Страница 33: ...5 1 Glass Assembly SRV7058 015 Y 5 2 Rope Door 3 4 X 84 832 1680 Y Corner Tape 1 Ft SRV560 437 9 Gasket Glass Tape 3 4 X 1 8 5 Ft 832 0460 Y 5 3 Hinge Pin 1 2 Nickel SRV430 5320 5 4 Door Handle Assemb...

Страница 34: ...ide Qty 2 req SRV7059 153 16 Blower Convection SRV7000 108 Y 17 Wire Harness SRV7058 150 Y 18 Blower Retainer SRV7058 148 19 Control Board 3 Speed Eco Choice SRV7058 188 Y 20 Latch Backing Plate SRV70...

Страница 35: ...stat Mechanical 812 3760 Y Paint Touch Up 3 42 19905 Hose Vacuum 5 32 Id 3 Ft SRV240 0450 Y Hose Barb Assembly SRV229 0920 Reset Button Assembly SRV7000 040 Baffle Center Back SRV7058 166 Collar Offse...

Страница 36: ...rtant operating and maintenance instructions included Read understand and follow these instructions for safe installation and operation Leave this manual with party responsible for use and operation o...