A. Wiring Requirements

NOTICE: 

This appliance must be electrically wired 

and grounded in accordance with local codes or, in the 
absence of local codes, with 

National Electric Code 

ANSI/NFPA 70-latest edition

 or the 

Canadian Electric 

Code CSA C22.1.

•  Wire the appliance junction box to 110-120 VAC. This is 

required for use of optional accessories (standing pilot 
ignition) or proper operation of the appliance (IntelliFire 
ignition).

•  A 110-120 VAC circuit for this product must be protected 

with ground-fault circuit-interrupter protection, in 
compliance with the applicable electrical codes, when 
it is installed in locations such as in bathrooms or near 
sinks.

•  Low voltage and 110-120 VAC voltage cannot be shared 

within the same wall box.

WARNING! Risk of Shock or Explosion! DO NOT

 wire 

110V to the valve or to the appliance wall switch. Incorrect 
wiring will damage controls.

B.  IntelliFire Ignition System Wiring

•  Wire the appliance junction box to 110-120 VAC for 

proper operation of the appliance.

WARNING! Risk of Shock or Explosion! 

DO NOT wire 

IPI controlled appliance junction box to a switched circuit. 
Incorrect wiring will override IPI safety lockout.

•  Refer to Figure 12.1, IntelliFire Pilot Ignition (IPI) Wiring 

Diagram.

•  This appliance is equipped with an IntelliFire control valve 

which operates on a 3 volt system.

•  Plug the 3-volt AC transformer into the appliance junction 

box to supply power to the unit OR install two D cell 
batteries (not included) into the battery pack before use.

NOTICE: 

Batteries should not be placed in the battery 

pack while using the transformer. Remove batteries before 
using the transformer, and unplug the transformer before 
installing the batteries. Battery polarity must be correct or 
module damage will occur.

C. Optional Accessories Requirements

•  This appliance may be used with a wall switch or a remote 

control.

Wiring for optional Hearth & Home Technologies approved 
accessories should be done now to avoid reconstruction. 
Follow instructions that come with those accessories.

12 

12 

Electrical Information 

 

Note:

  A blower kit is not approved for this appliance.

Содержание BGST4336I

Страница 1: ...hat to do if you smell gas DO NOT try to light any appliance DO NOT touch any electrical switch DO NOT use any phone in your building Leave the building immediately Immediately call your gas supplier...

Страница 2: ...pe of Gas Model Number Not Not for for use use with with solid solid fuel fuel Ne Ne doit doit pas pas entre entre utilise utilise avec avec un un combustible combustible solide solide This This appli...

Страница 3: ...Tools and Supplies Needed 15 D Inspect Appliance and Components 15 E Negative Pressure 16 5 Framing and Clearances A Selecting Appliance Location 17 B Constructing the Appliance Chase 18 C Clearances...

Страница 4: ...2135 900 Rev L 12 15 4 Contains updated information 15 Troubleshooting A Intellifire Ignition System 38 16 Reference Materials A Appliance Decorative Front Dimension Diagrams 40 B Service Parts 42 C C...

Страница 5: ...f original purchase In the case of new home construction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorize...

Страница 6: ...NS This warranty does not cover the following Changes in surface finishes as a result of normal use As a heating appliance some changes in color of interior and exterior surface finishes may occur Thi...

Страница 7: ...as primary heat in residential heating calculations D High Altitude Installations NOTICE If the heating value of the gas has been reduced these rules do not apply Check with your local gas utility or...

Страница 8: ...n Never leave children alone near a hot fireplace whether operating or cooling down A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall...

Страница 9: ...prevent direct contact with the fixed glass panel DO NOT operate the fireplace with the barrier removed Contact your dealer or Hearth Home Technologies if the barrier is not present or help is needed...

Страница 10: ...lean See installation and operating instruc tions accompanying appliance Hot while in operation DO NOT touch Keep children clothing furniture gasoline and other liquids having flammable vapors away DO...

Страница 11: ...will disappear Blue flames This is a result of normal operation and the flames will begin to yellow as the fireplace is al lowed to burn for 20 to 40 minutes Odor from fireplace When first operated t...

Страница 12: ...cing When properly maintained your fireplace will give you many years of trouble free service We recommend an nual service by a qualified service technician Surrounds Decorative Fronts Frequency Annua...

Страница 13: ...hese areas Screw tips that have penetrated the sheet metal are sharp and should be avoided Remove all foreign objects Verify unobstructed air circulation Burner Ignition and Operation Frequency Annual...

Страница 14: ...L WALL SWITCH STORM COLLAR SECTION 4D NON COMBUSTIBLE ROOF FLASHING MAINTAINS MINIMUM CLEARANCE AROUND PIPE FRAMING HEADER SECTION 5 ATTIC INSULATION SHIELD NOT SHOWN MUST BE USED HERE TO KEEP INSULAT...

Страница 15: ...could impair safe operation DO NOT install damaged in complete or substitute components Keep appliance dry C Tools and Supplies Needed Before beginning the installation be sure that the following too...

Страница 16: ...ppliances and exhaust equipment Ensure furnace and air conditioning return vents are not located in the immediate vicinity of the fireplace Avoid installing the fireplace near doors walkways or small...

Страница 17: ...e or Burns Provide adequate clearance around air openings and for service access Due to high temperatures the appliance should be locat ed out of traffic and away from furniture and draperies NOTICE I...

Страница 18: ...ing full width and depth DO NOT install directly on carpeting vinyl tile or any combustible material other than wood WARNING Risk of Fire Maintain specified air space clearances to appliance and vent...

Страница 19: ...10 11 12 2 1 2 13 14 15 16 17 18 19 32 TO CEILING 9 10 11 12 8 7 6 5 4 3 25 18 MAX MIN MEASUREMENTS FROM TOP EDGE OF THE OPENING 10 11 12 18 9 8 7 6 1 2 3 4 5 6 12 32 MAX MIN TO CEILING GBST4336I Man...

Страница 20: ...insulation or other materials Failure to keep insulation or other materials away from vent pipe may cause overheating and fire WARNING Gas Wood or Fuel Oil Termination Cap B Gas Termination Cap A If u...

Страница 21: ...ENT SUPPORTS ARE PER VENT MANUFACTURER S SPECIFICATIONS METAL PLUMBER S STRAP 12 FEET MINIMUM 50 FEET MAXIMUM VENT SUPPORTS ARE PER VENT MANUFACTURER S SPECIFICATIONS MINIMUM CLEARANCES ARE PER VENT M...

Страница 22: ...instructions to provide adequate clear ances Use same size framing materials as those used in the wall or ceiling construction Firestop spacers must be used in wall and ceiling penetrations per the B...

Страница 23: ...ay result Remove and discard cover plate or knockout from side of appliance Open air kit damper slightly Locate door hinge toward back of appliance see Figure 9 1 9 9 Appliance Preparation Figure 9 2...

Страница 24: ...ion 8 for hole location 2 Place the appliance into position making sure to maintain proper clearance to combustibles 3 Level the appliance from side to side and front to back It is acceptable to use w...

Страница 25: ...S FLUE OUTLET COLLAR Attach the first B Vent component to the flue outlet collar using 3 self tapping screws See Figure 8 1 WARNING Risk of Fire or Explosion Use vent run supports per vent manufacture...

Страница 26: ...ak check solution DO NOT use open flame Fittings and connections could have loos ened during shipping and handling WARNING Risk of Fire DO NOT change valve settings This valve has been preset at the f...

Страница 27: ...ance junction box to 110 120 VAC for proper operation of the appliance WARNING Risk of Shock or Explosion DO NOT wire IPI controlled appliance junction box to a switched circuit Incorrect wiring will...

Страница 28: ...proper operation after servicing WARNING Risk of Shock Replace damaged wire with type 105 C rated wire Wire must have high temperature insulation RED VALVE TRANSFORMER 3V BLACK B R O W N WIRE ASSEMBL...

Страница 29: ...SIDE of the appliance Determine which side of the appliance the junction box is located on Pull the electrical wires from outside the appliance through the knockout making sure to use a Romex connecto...

Страница 30: ...Top Flap Step 3 Crease flaps on left and right sides of splatter guard using the scored line as the guide See Figure 13 3 Step 4 Center the splatter guard in front of the unit as shown in Figure 13 4...

Страница 31: ...and fold up the panel as shown in Figure 13 8 Disengage the tabs on left and right bottom of splatter guard and fit them into the square holes The tabs are now inside the front of the splatter guard c...

Страница 32: ...g TOP VIEW 3 1 4 in Min 2 3 4 in Min 1 2 in Min Unlimited 1 in Max FIREPLACE OPENING Note Clearance from opening to perpendicular wall C Facing Material Metal front faces may be covered with non combu...

Страница 33: ...properly placed embers interfere with proper burner operation Ember material is shipped with this gas appliance To place the ember material Embers CANNOT be placed directly over ports Care should be t...

Страница 34: ...2 Factory Installed Logs and Pilot Position STEP 1 Log 1 SRV2129 704 Place Log 1 on Log A The end and bottom of Log 1 fit into the indentation on Log A highlighted in Figure 3 The Y shaped end of Log...

Страница 35: ...tions located on Log 2 and Log D Log 3 should extend beyond Log 2 by one inch Figure 8 Placement of Log 3 Figure 5 Placement of Log 2 Figure 7 Placement of Log 3 B B C C D D B B 2 2 BURNER EDGE BURNER...

Страница 36: ...s highlighted in Figure 11 Place that portion of Log 2 on the indentation on Log C Log 2 will rest on the tip of Log B Slide the bottom of Log 2 up to the edge of the burner as shown in Figure 12 C C...

Страница 37: ...Fixed Glass Assembly Removing Fixed Glass Assembly WARNING Risk of Asphyxiation Handle fixed glass assembly with care Inspect the gasket to ensure it is undamaged and inspect the glass for cracks chi...

Страница 38: ...racked insulator around electrode Replace pilot if necessary 2 Pilot won t light there is no noise or spark a No power or transformer installed incorrectly Verify that transformer is installed and plu...

Страница 39: ...should glow shortly after ignition Verify cor rect pilot orifice is installed and gas inlet is set to pressure specifications c Module is not grounded Verify module is securely grounded to metal chas...

Страница 40: ...aming dimensions and clearances refer to Section 3 Figure 16 1 GBST4336I Appliance Dimensions Location Inches Millimeters I 4 1 4 108 J 24 610 K 12 305 L 21 5 16 541 M 5 127 N 38 965 O 1 25 Location I...

Страница 41: ...D E F G GBST4336I CRAFT 36C in 32 1 16 21 9 16 35 7 8 1 1 8 7 1 16 32 1 4 33 3 8 mm 814 548 911 29 179 819 848 CRAFT DECORATIVE FRONTS G A B C D E F G A B C D E F A B C D E F G GBST4336I SIM 36C in 32...

Страница 42: ...RV2129 701 B Log B SRV2129 703 C Log C SRV2129 702 D Log D SRV2129 706 1 Log 1 SRV2129 704 2 Log 2 SRV2129 705 3 Log 3 SRV2129 707 4 Sheetrock Ledge 2128 118 5 Refractory 2135 017 6 Limit Switch Assem...

Страница 43: ...PTION COMMENTS PART NUMBER 10 1 Shutter Bracket Assembly 2118 121 Y 10 2 Pilot Assembly NG 2090 012 Y Pilot Assembly LP 2090 013 Y 10 3 Flexible Gas Connector 530 302A Y 10 4 Flex Ball Valve Assembly...

Страница 44: ...ce parts from your dealer or distributor Stocked at Depot ITEM DESCRIPTION COMMENTS PART NUMBER 72 inch Wire Assembly 258 501A Y 80 inch Wire Assembly 522 501A Y Glass Latch Assembly Pkg of 2 33858 2...

Страница 45: ..._________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ____...

Отзывы: