background image

2

595-5291-07

TEST AND ADJUSTMENT

NOTE:

 Sensor has a 30 second warm up period before 

it  will  detect  motion. When  switching  modes  wait  30 
seconds.

1.  Slide  the  sensor  switch  to  the TEST  (center)  posi-

tion.

2.  Place the RANGE adjustment in the medium position 

(halfway between MIN and MAX position).

 

Least Sensitive 

Most Sensitive

Sensor

Motion

60 ft. 
(18.3 m)

8 ft. 
(2.4 m)

 

Maximum Range 

Maximum

 

Coverage Angle

110°

RANGE

OFF

MIN

MAX

TEST

AUTO

Bottom of Sensor

Aim Sensor Down for 

Short Coverage

Aim Sensor Higher for 

Long Coverage

Ball Joint

Clamp Screw

Adjustment of Coverage Area

The sensor detects “motion” by the movement of heat 
(body heat) across the coverage area. However, following 
are examples of objects that also produce heat and can 
cause the sensor to false trigger:
•  Pools of Water 

•  Air Conditioners

•  Dryer Vents 

•  Fenced-In Animals

•  Heating Vents 

•  Automobile Traffic

If you suspect that a heat source of this type is falsely 
triggering the sensor, try reducing the RANGE or aiming 
the sensor away from the heat source in question.

Note:

 The  detector  is  less  sensitive  to  motion  directly 

towards it and more sensitive to across motion. 

Motion

OPERATION

Place the sensor switch in AUTO for normal operation. If the 
light is not needed, put the switch in the OFF position.

Mode:

On-Time

Works:

Day

Night

Test

5 Seconds

x

x

Auto

30 Seconds

x

THINGS TO REMEMBER

•  Periodically clean the solar panel with a soft cloth and 

warm water. Do not hose spray. Keep the collector clear 
of snow and leaves. Make sure trees and other objects 
do not block sunlight from the panel.

•  If not to be used for several weeks, turn the unit OFF. 

Store it with the panel connected and where the panel 
can gather sunlight.

•  Solar collection is only effective in direct sunlight. Every 

hour the light is on requires a minimum of 16 hours of 
sunlight charging. Solar panels collect less than 10% 
of the sun’s energy. Light bulbs convert this energy to 
light at 5% efficiency.

•  Several days of use with overcast skies may discharge 

the battery. Because of the battery protection circuit, the 
light will not work until the battery is fully recharged.

•  This light is supplied with a 15 Watt, bi-pin, halogen 

bulb. For replacement, use Heath

®

/Zenith model SL-

7000-A1-A or equivalent. 

Note:

 Using a larger bulb will 

decrease battery life.

3.  Loosen the clamp screw in the sensor ball joint.

4.  Walk through the coverage area noting when the lights 

turn on. Gently move the sensor head up, down, or 
sideways to change the coverage area. 

Note:

 Wait 5 

to 10 seconds after light turns off to retest.

5.  Increase RANGE only as needed. A  larger  RANGE 

setting may cause false triggering and reduce battery 
life.

6.  Secure the sensor into position by tightening the clamp 

screw. Do not overtighten the screw.

7.  After dark, adjust the light to cover desired area.

Содержание SL-7001

Страница 1: ...items INSTALLATION For best performance mount the fixture about 8 feet 2 4 m above the ground 1 Mount solar panel base on a solid surface using threetaperedscrews Adjustthepaneltopointdirectly at the noon sun Avoid obstructions such as trees or buildings that may block sun light Allow for enough wire to reach the case Keep ball joint at bottom Note You will want to re aim the solar panel as the sea...

Страница 2: ... Night Test 5 Seconds x x Auto 30 Seconds x THINGS TO REMEMBER Periodically clean the solar panel with a soft cloth and warm water Do not hose spray Keep the collector clear of snow and leaves Make sure trees and other objects do not block sunlight from the panel If not to be used for several weeks turn the unit OFF Store it with the panel connected and where the panel can gather sunlight Solar co...

Страница 3: ...ously sold IMPORTANT Replacelamponlywithsametypelamp 20 watts or less DO NOT reverse the battery wires Damage to the unit will result Like any lead acid battery this battery must be disposed of properly IMPORTANT Keep sensor switch in the OFF position for three days to allow the battery to fully charge before testing 1 Remove rear battery cover Press in the two catch releases on the cover and remo...

Страница 4: ...fore returning product to store If you experience a problem follow this guide You may also want to visit our Web site at www desatech com If the problem persists call for assistance at 1 800 858 8501 7 30 AM to 4 30 PM CST M F You may also write to DESA Specialty Products ATTN Technical Service Specialty Products P O Box 90004 Bowling Green KY 42102 9004 If contacting Technical Service please have...

Страница 5: ...a la base del panel solar 2 Monte la caja de la batería sobre una superficie sólida usando dos tornillos de cabeza redonda y los orificios en la parte de atrás de la caja 3 Acomode el Detector Para una operación correcta la cabeza del detector debe girarse de modo que los controles del detector queden ubicados hacia abajo como se muestra a continuación 17 15 cm Orificios de montaje 3 Orificios de mont...

Страница 6: ...nde Unión Esférica Tornillo Sujetador Regulación del Área de Cobertura El detector detecta movimiento por el movimiento del calor calor corporal a través del área de cobertura Sin embargo a continuación están ejemplos de objetos que pueden producir calor y hacer que el detector active una falsa alarma Charcos de agua Acondicionadores de aire Ventosas de la secadora Animales en vallas Ventosas de c...

Страница 7: ...el pueda guardar la luz solar Lacolecciónsolaressoloefectivabajolaluzdirectadel sol Por cada hora que la luz está prendida requiere un mínimo de 16 horas de carga de luz solar Los paneles solares recolectan menos del 10 de la energÌa solar Las bombillas convierten esta energÌa en luz con una eficiencia del 5 Si la usa durante varios días nublados la batería se puede descargar Debido al circuito de ...

Страница 8: ... preguntas en español por teléfono Usted puede también escribir a DESA Specialty Products P O Box 90004 Bowling Green KY 42102 9004 Si se llama al Servicio Técnico por favor tener lista la siguiente información Número de Modelo Fecha de compra y Lugar de compra No hay piezas de servicio disponibles para este producto GARANTÍA LIMITADA A 5 AÑOS Esta es una Garantía Limitada que le da a Ud derechos ...

Страница 9: ...panneau solaire 2 Installer le boîtier de la pile sur une surface so lide au moyen des deux vis à tête ronde en vous servant des orifices en trou de serrure à l arrière du boîtier 3 Régler le capteur Pour fonctionner correctement le capteur doit être placé de façon que les commandes soient face au sol comme illustré ci dessous 17 15 cm Orifices de fixation 3 Orifices de fixation 2 2006 DESA Specialty P...

Страница 10: ...mouvements en décelant le passage d une source de chaleur chaleur corporelle dans la zone de couverture Voici toutefois des exem ples d objets qui dégagent aussi de la chaleur et qui par conséquent peuvent entraîner le déclenchement intempestif du capteur Piscine Appareil de climatisation Évent de sécheuse Animaux en cage Évent de ventilation Circulation automobile Si vous croyez qu une source de ...

Страница 11: ... la pile FICHE TECHNIQUE Portée Jusqu à 18 3 m 60 pi Varie selon la température ambiante Angle de détection Jusqu à 110 Ampoule 15 W 6 V à halogène Type de pile Scellée au plomb acide 6V 6 0 AH Durée de fonctionnement 30 secondes redéclenchable Durée de fonctionnement à pleine charge Jusqu à 1 heure REMPLACEMENT DE LA PILE Celuminaireàénergiesolairecomporteunepilerechargea ble qui peut être rempla...

Страница 12: ...tés suivez ce guide Vous pouvez également écrire à l adresse suivante DESA Specialty Products P O Box 90004 Bowling Green KY 42102 9004 Lors d un appel au service technique veuillez avoir les renseignements suivants à portée de main numéro du mo dèle date d achat et endroit de l achat Aucune pièce de rechange n est disponible pour ce produit GUIDE DE DÉPANNAGE SYMPTÔME CAUSE POSSIBLE SOLUTION L éc...

Отзывы: