background image

3

598-1120-04

SPECIFICATIONS

Range . . . . . . . . . . . . Up to 70 ft. (21 m) [varies with 

surrounding temperature].

Sensing Angle . . . . . . Up to 180°
Electrical Load . . . . . . Up  to  120  Watts  Maximum 

Incandescent  [Up  to  60 Watts 
Maximum each lamp holder.]

 

Up  to  40  Watts  Maximum 
Fluorescent  [Up  to  20  Watts 
Maximum each lamp holder.]

Power Requirements . 120 VAC, 60 Hz
Operating Modes . . . . TEST,  AUTO  and  MANUAL 

MODE

Time Delay  . . . . . . . . 1, 5, 10 minutes
Range . . . . . . . . . . . . Adjustable 

HeathCo LLC reserves the right to discontinue prod-
ucts and to change specifications at any time without 
incurring any obligation to incorporate new features in 
products previously sold.

Motion

Motion

TEST AND ADJUSTMENT

 

Turn on the circuit breaker and light switch.

Least Sensitive

 

Most Sensitive

Sensor

The detector is most sensitive to motion across its field 
of view.

 

Maximum Range 

Maximum

 

 

Coverage Angle

NOTE:  Sensor has about 1 

1

/

2

 minutes warm up period 

before it will detect motion. When first turned 
on, wait about 1 

1

/

2

 minutes.

Bottom of Sensor

Avoid aiming the control at:

•  Objects  that  change  temperature  rapidly,  such  as 

heating  vents  and  air  conditioners.  These  heat 
sources could cause false triggering.

•  Areas where 

pets or traffic may trigger the control.

•  

Nearby large, light-colored objects reflecting light 
may trigger the shut-off feature. Do not point other 
lights at the sensor.

180°

70 ft. 

(21 m)

8 ft. 

(2.4 m)

  Turn the RANGE control to the mid position and the 

ON-TIME control to the TEST position.

  Loosen the clamp screw in the 

sensor  ball  joint  and  gently 
rotate the sensor.

  Walk through the coverage area 

noting where you are when the 
lights turn on (also, the LED will 
flash several times when motion 
is detected). Move the sensor 
head  up,  down,  or  sideways 
to change the coverage area. 
Keep  the  sensor  at  least 
1"  (2.5  cm)  away  from  the 
lamps.

  Adjust the RANGE as needed. 

RANGE  set  too  high  may 
increase false triggering.

 

Secure the sensor head by 
tightening the clamp screw.
 
Do not overtighten the screw.

  Set the amount of TIME you want the lights to stay 

on after motion is detected (1, 5, or 10 minutes). 
Note:  One  minute  mode  is  not  recommended  for 
use with compact fluorescent bulbs.

Warning - Risk of fire. Do not aim the lamps at a 
combustible surface within 3 ft. (1 m).

RANGE

10 5 1 TEST

ON-TIME

MIN 

MAX

Clamp 
Screw

 

Ball 
Joint

Aim Sensor 

Down for Short 

Coverage

Aim Sensor 

Higher for Long 

Coverage

Содержание SL-5710

Страница 1: ...des OPERATION resets to Auto Mode at dawn Note When first turned on wait about 1 1 2 minutes for the circuitry to calibrate MANUAL MODE ON TIME 10 5 1 TEST 10 5 1 TEST ON TIME TEST back on AUTO 1 Second OFF then Put the ON TIME switch in the 1 5 or 10minuteposition Note Althoughthe 1 minute mode can be used the 5 or 10 minute mode is recommended for bestoperationandperformancewhen using compact fl...

Страница 2: ...Black Gasket For eave mount only Swing the sensor head towards the clamp screw joint If the sensor pops out of the ball joint loosen the clamp screw and push the sensor back into the ball joint Tighten the clamp screw when done Then rotate the sensor head clockwise 180 so the controls face down Controls Wall Mount Eave Mount For under eave installation the sensor head must be rotated as shown in t...

Страница 3: ...s and air conditioners These heat sources could cause false triggering Areas where pets or traffic may trigger the control Nearby large light colored objects reflecting light may trigger the shut off feature Do not point other lights at the sensor 180 70 ft 21 m 8 ft 2 4 m Turn the RANGE control to the mid position and the ON TIME control to the TEST position Loosen the clamp screw in the sensor b...

Страница 4: ...ing Green KY 42102 9004 ATTN Technical Service If contacting Technical Service please have the following information available Model Number Date of Pur chase and Place of Purchase No Service Parts Available for this Product TEN YEAR LIMITED WARRANTY This is a Limited Warranty which gives you specific legal rights You may also have other rights which vary from state to state or province to province...

Страница 5: ...NUAL ON TIME 10 5 1 TEST 10 5 1 TEST ON TIME Para PRUEBA préndalo Para AUTOMATICO 1 segundo APAGADO luego Ponga el interruptor de tiempo ON TIME en la posición de 1 5 ó 10 minutos Nota Aunque se puedeusarlamodalidadde1minuto se recomienda la de 5 ó 10 minutos paraobtenerelmejorfuncionamiento yrendimientocuandoseusenbombil las fluorescentes compactas Ponga el interruptor de tiempo ON TIME al fondo ...

Страница 6: ...hacia la unión del tornillo sujetador Sieldetectorsesaledelauniónesférica aflojeeltornillo sujetador y empuje el detector hacia dentro de la unión esférica Apriete el tornillo sujetador cuando termine Entonces gire la cabeza del detector hacia la derecha por 180 hasta que los controles miren hacia abajo Controles Montaje en pared Montaje en alero Para instalarlo bajo el alero la cabeza del detecto...

Страница 7: ...de operación PRUEBA AUTOMATICO y MODO MANUAL Retardo de Tiempo 1 5 ó 10 minutos Alcance Ajustable HeathCo LLC se reserva el derecho de descontinuar productos y de cambiar especificaciones a cualquier momento sin incurrir en ninguna obligación de tener que incorporar nuevas características en los productos vendidos con anterioridad Alcance Máximo Angulo de Cobertura Máxima NOTA El detector tiene un...

Страница 8: ...M a 4 30 PM CST L V Usted puede también escribir a HeathCo LLC P O Box 90004 Bowling Green KY 42102 9004 ATTN Technical Service Servicio Técnico Si se llama al Servicio Técnico por favor tener lista la siguiente información Número de Modelo Fecha de compra y Lugar de compra No hay piezas de servicio disponibles para este producto GARANTÍA LIMITADA A 10 AÑOS Esta es una Garantía Limitada que le da ...

Страница 9: ...du détecteur Le mode manuel ne fonctionne que la nuit parce que la lumière du jour remet le capteur en mode AUTO Mettre l interrupteur hors circuit pendant une seconde plus en circuit pour alterner entre les modes AUTO et MANUEL Le mode manuel ne fonctionne qu avec l interrupteur ON TIME aux positions 1 5 ou 10 Placer l interrupteur ON TIME à 1 5 ou 10 minutes Résumé du mode de commutation Mettre ...

Страница 10: ...u détecteur en direction du joint à vis de blocage Si le détecteur sort de la rotule desserrer la vis de blocage et ré insérer le détecteur dans la rotule et resserrer la vis Puis faire pivoter le détecteur sur 180 de façon que les commandes soient tournées vers le bas Commandes Montage mural Montage sous avant toit Pouréviterlerisquedechocélectrique lescommandes du détecteur doivent être tournées...

Страница 11: ...etpriorité manuelle Délais 1 5 et 10 minutes Portée Réglable HeathCo LLC se réserve le doit d abandonner tout produit et d en changer les spécifications en tout temps et sans contracter quelque obligation que ce soit quant à l incorporation de nouvelles caractéristiques aux produits déjà vendus NOTE Lecapteurdoitseréchauffer1 1 2 minuteavant de pouvoir détecter le mouvement Lorsque l appareil est ...

Страница 12: ...ng Green KY 42102 9004 ATTN Technical Service Service technique Lors d un appel au service technique veuillez avoir les renseignements suivants à portée de main numéro du modèle date d achat et endroit de l achat Aucune pièce de rechange n est disponible pour ce produit GARANTIE LIMITÉE DE 10 ANS Il s agit d une Garantie limitée qui vous confère des droits juridiques spécifiques Vous pouvez égalem...

Отзывы:

Похожие инструкции для SL-5710