HEAT & GLO • PHOENIX42-IFT Installation Manual • 4096-901 Rev. A
• 02/18
40
Figure 11.8
•
Set Left & Right Side Refractories in place. See Fig
-
ure 11.9.
Fiber Refractory Installation
Note
: Unpack refractory panels carefully to avoid damag
-
ing the panels.
•
Remove smoke shield (5) screws and set the smoke
shield aside.
•
Set Back Refractory in place and secure with (1) re
-
fractory retainer. See Figure 11.8.
Refractory Retainer
Figure 11.9
Back Glass Panel
•
Bend up (2) lower retaining tabs on rear refractory
brackets, set the back glass panel on rear brackets,
bend down (2) upper retaining tabs to secure glass
panel in place.
Left Glass Panel
•
Bend up (2) lower retaining tabs on left refractory
brackets, set the left glass panel on left brackets,
bend down (2) upper retaining tabs to secure glass
panel in place.
Right Glass Panel
•
Bend up (2) lower retaining tabs on right refractory
brackets, set the right glass panel on right brackets,
bend down (2) upper retaining tabs to secure glass
panel in place. See Figures 11.5 & 11.6.
Left Refractory
Right Refractory
Back Refractory
Figure 11.6
Bend Tabs
Figure 11.7
Continue to “Reinstalling the Smoke Shield” section.