![Heat&Glo PHOENIX42-IFT Скачать руководство пользователя страница 17](http://html.mh-extra.com/html/heatandglo/phoenix42-ift/phoenix42-ift_installation-manual_2116063017.webp)
17
HEAT & GLO • PHOENIX42-IFT Installation Manual • 4096-901 Rev. A
• 02/18
SLG
Pipe
Effective Length
Rise/Run
Inches
Millimeters
Inches
Millimeters
SLG4
2-3/4
70
2
49
SLG6
4-3/4
121
3-3/8
85
SLG12
10-3/4
273
7-5/8
193
SLG24
22-3/4
578
16-1/8
409
SLG36
34-3/4
883
24-5/8
624
SLG48
46-3/4
1187
33
840
RUN
RISE
EFFEC
TIVE
LENGTH
VERTICAL
HORIZONTAL
D. Measuring Standards
Vertical and horizontal measurements listed in the vent
diagrams were made using the following standards:
• Pipe measurements are shown using the effective length
of pipe. See Figure 4.4 for information on effective length
of pipe components.
• Total vent length is measured from the start of the vent
run, to the end of the vent run, including straight pipe as
well as elbows.
• Horizontal pipe installed level with no rise.
Fire Risk.
PHOENIX models must be power vented
using the termination cap supplied with the
appliance. Failure to vent properly could
cause overheating and fire.
WARNING
•
The PHOENIX comes standard with a 2 minute
pre-purge function designed to remove gas from
the appliance and establish a positive draft for the
vent system.
•
The PHOENIX comes standard with a 20 minute
post-purge function designed to eliminate condensa-
tion in the venting system components.
SLG
Pipe
Horizontal
Vertical
Inches
Millimeters
Inches
Millimeters
SLG4
8-7/8
225
18-5/8
473
SLG6
10-1/4
260
20
508
SLG12
14-1/2
368
24-1/4
616
SLG24
23
584
32-3/4
832
SLG36
31-1/2
800
41-1/4
1048
SLG48
39-7/8
1013
49-5/8
1260
Figure 4.4 Elbow Chart