CAUTION! Risk of Cuts, Abrasions or Flying Debris.
Wear protective gloves and safety glasses during instal-
lation. Sheet metal edges are sharp.
A. Vent Collar Preparation
6
Appliance Preparation
• Remove the (8) screws that attach the cover plate and
vent collar box to the rear of the appliance.
• Remove the cover plate and vent collar box with
insulation from the rear of the appliance.
• Remove the (8) screws that attach the solid cover plate
and vent box to the top of the appliance.
• Relocate the solid cover plate and vent box with
insulation from the top of the appliance to the rear of
the appliance and replace (8) screws.
Figure 6.2
Figure 6.3
Figure 6.4
Figure 6.1
• Install the cover plate and vent collar with insulation to
the top of the appliance and replace (8) screws.
Figure 6.5
The PHOENIX appliance is shipped with the vent collar
installed in the rear vent position. If top venting is re
-
quired, the vent collar will need to be moved from the rear
of the appliance to the top of the appliance.