![Heat&Glo PHOENIX42-IFT Скачать руководство пользователя страница 30](http://html.mh-extra.com/html/heatandglo/phoenix42-ift/phoenix42-ift_installation-manual_2116063030.webp)
HEAT & GLO • PHOENIX42-IFT Installation Manual • 4096-901 Rev. A
• 02/18
30
Figure 7.18
Wire Harness Retaining
Plate
•
Route wire harness through motor assembly and re
-
taining plate, secure with Romex connector. Reattach
retaining plate to motor assembly, (2) screws. Install
motor assembly onto cap base and secure with (8)
screws. See Figure 7.19.
Figure 7.19
Retaining Clips
Figure 7.20
Figure 7.21
• Secure wire harness and motor wires with retaining
clips (2) as shown. See Figure 7.20.
•
Reattach louvered cover, (8) screws. See Figure
7.21.
The use of a decorative only shroud is permitted on
PHOENIX appliances that terminate from a vertical chase
type structure. Enclosing the termination cap within the
decorative shroud is NOT permitted.
F. Shrouds
•
Remove wire harness retaining plate from motor as
-
sembly, (2) screws. See Figure 7.18