background image

 
 
 

 

 

Heat Trap 

Operating Instructions

Models 

 

HTS340-CP1 

 

HTS340-CP2 

 

HTS340-CP3 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

HT00IM0062 

Trap Hybrid Hot Water System

nstructions and Warranty Policy

 

 

ater System 

and Warranty Policy

 

Содержание HTS340-CP1

Страница 1: ...Heat Trap Operating Instructions Models HTS340 CP1 HTS340 CP2 HTS340 CP3 HT00IM0062 Trap Hybrid Hot Water System nstructions and Warranty Policy 1 ater System and Warranty Policy ...

Страница 2: ...cation Table of Contents 1 Owners Information 3 2 System Maintenance 7 3 Important Installation Notes 9 8 Electrical Installation 25 11 Warranty Policy 12 13 Post Installation Check Sheet 14 PATENTS This water heater may be protected by one or more patents or registered designs in the name of Heat Trap Solar Pty Ltd TRADE MARKS Registered trademark of Heat Trap Solar Pty Ltd ...

Страница 3: ...se by small children or infirm persons without supervision Young children should be supervised to ensure that they do not play with the appliance ecifically designed for residential hot water heating and is not suita Heat Pump operation Ambient air is drawn through a heat exchanger much like a radiator The energy in the air is absorbed into refigerant gas which is then compressed The heat energy i...

Страница 4: ...Heat Trap Hybrid Heat Pump Installation O Heat Trap Hybrid Heat Pump Installation O Heat Trap Hybrid Heat Pump Installation Operating Instructions 4 ...

Страница 5: ...d to do anything other than turn on the electricity and water supplies The Heat Pump module is electrically connected to the storage tank and will start automatically when the water e tank falls below the controlled set point Heat Trap Solar Energy Management System EMS The EMS has been factory set and should not be tampered with Access to the system must only be done through direct contact with t...

Страница 6: ...humb an average size house using 200 litres of hot water a day in Spring or Autumn running time of 5 to 6 hours depending on the installation location If a solar system has been installed the running time will vary according to the amount of solar energy that has been absorbed For example in the summer months the heat pump booster not run at all whereas in winter when there is much less free energ...

Страница 7: ...om an unfiltered water source that may be highly conductive or have a high mineral t may void the system warranty Therefore to ensure water quality guidelines are met the following characteristics should not be Table 1 Water quality requirements In areas of poor water quality it is recommended that a softener conditioner or similar device be Where the mains water supply pressure is greater than 55...

Страница 8: ... a trained Heat Trap technician Hail Damage It is advisable to replace the Flat plate collector as soon as possible to ensure maximum system efficiency Any broken glass should be cleared away to the Flat plate collector by yourself This task should only be attempted by an authorised Heat Trap Solar representative or suitably qualified person very robust and has been tested to Australian Standards ...

Страница 9: ... Pump Installation O are not required Heat pump is a low pressure system Any expansion is taken up within the low pressure tank This is done automatically for the relief of any expansion or relief valves s are not required Solar Hybrid Tank is entirely constructed of non ferrous materials The container is made from polyethylene and conforms to AS NZS 2712 hybrid tank does not require an anode and ...

Страница 10: ...e in conflict the local regulations shall commence until all safety issues have been addressed n should only be performed by an approved professional with suitable experience and authorised by Heat Trap Solar to conduct the work It is imperative that installers adhere to Occupational Health and Safety Guidelines at all times The installer is responsible for their own safety and the safety of those...

Страница 11: ...service agent or a The Heat Trap EMS control system has no user adjustable parameters and cannot be changed control parameters have been designed to achieve maximum efficiency and have been used determine the amount of Small Technology Credits that you will receive The controller board is located inside the weatherproof cover on the front of the Heat Trap tank and has no keypad or display facility...

Страница 12: ...cost of additional materials handling and or safety equipment shall be the owner s responsibility system must be sized to supply the hot water demand in accordance with the guidelines Hybrid Solar and Heat Pump Water Heater System literature Where the Hybrid Solar Hot water System is installed outside the boundaries of a metropolitan area as defined by Heat Trap Solar or further than 50 kilometres...

Страница 13: ...sure verflow vent drain has been blocked or corroded Subject to the Warranty Conditions and Exclusions stated above your Hybrid tank and Heat P from date of commissioning as follows PARTS LABOUR Polymer storage cylinder 10 years 3 years heat exchanger and piping 10 years 3 years 5 years 3 years 2 years 1 year 2 years 1 year Subject to any statutory provisions to the contrary this warranty excludes...

Страница 14: ...ck off each item in the check list is well bled and ALL air has been purged from the system he tank is installed on a level sturdy surface omposite base has been installed here is no water leaking from the heat pump flow and return lines and fittings he wiring between the tank and the heat pump unit is properly connected dedicated water supply isolation valve has been installed the cold water inle...

Отзывы: