)NSTALLINGTHE3TOVE
CONTINUED
3TEP
)NSTALLINGTHE6ENT3YSTEM
!6ENT3YSTEM!PPROVALS
4HISMODELISAPPROVEDFORvANDv3,$3ERIES
VENT PIPE COMPONENTS AND TERMINATIONS4HIS PIPE IS
TESTED AND LISTED AS AN APPROVED COMPONENT OF THE
STOVE 4HE PIPE IS TESTED TO RUN INSIDE AN ENCLOSED
WALL4HEREISNOREQUIREMENTFORINSPECTIONOPENINGS
AT EACH JOINT WITHIN THE WALL4HERE IS NO REQUIRED
PITCHFORHORIZONTALVENTRUNS!PPROVEDVENTSYSTEMS
COMPONENTSARELABELEDFORIDENTIlCATION
.//4(%2
6%.43934%-3/2#/-0/.%.43-!9"%53%$
$ETAILEDINSTALLATIONINSTRUCTIONSAREINCLUDEDWITHEACH
VENTTERMINATIONKITANDSHOULDBEUSEDINCONJUNCTION
WITHTHISMANUAL
7!2.).'
!MINIMUMFOOTLENGTHOFSTRAIGHT
VENTPIPE
-534
BEATTACHEDTOTHEUNITSSTARTING
COLLARS FOR ALL VENT SYSTEMS UNLESS USING THE
/IT$ONMODEL4IARA)
)DENTIFYING6ENT#OMPONENTS
4HE VENT SYSTEMS INSTALLED ON THIS GAS STOVE MAY
INCLUDEONETWOORTHREE
ELBOWASSEMBLIES4HE
RELATIONSHIPS OF VERTICAL RISE TO HORIZONTAL RUN IN VENT
CONFIGURATIONS USING ELBOWS
-534 "%
STRICTLY
ADHEREDTO4HERISETORUNRELATIONSHIPSARESHOWNIN
THE VENT DRAWINGS AND TABLES2EFER TO THE DIAGRAMS
ONTHENEXTSEVERALPAGES
»TAPE
)NSTALLATIONDUSYSTáMEDEVENTILATION
!(OMOLOGATIONSDUSYSTáMEDEVENTILATION
#EMODáLEESTHOMOLOGU£POURLES£L£MENTSETMITRES
DUNSYSTáMEDEVENTILATIONDEINETINDELA
S£RIE 3, $#E CONDUIT A £T£ TEST£ ET HOMOLOGU£ EN
TANTQU£L£MENTAGR££DELACHEMIN£E,ECONDUITA£T£
TEST£ENVUEDETREPOS£ALINT£RIEURDUNMURFERM£
!UCUNESP£CIlCATIONNEXIGELAPR£SENCEDOUVERTURES
DINSPECTIONAUNIVEAUDECHAQUEJOINTALINT£RIEURDU
MUR)LNEXISTEAUCUNESP£CIlCATIONDEPENTEPOURLES
CONDUITSHORIZONTAUX$ESAUTOCOLLANTSSONTAPPOS£S
SUR LES £L£MENTS HOMOLOGU£S
.54),)3%2 !5#5.
!542%3934³-%/5»,»-%.4$%6%.4),!4)/.
,ES INSTRUCTIONS DE MONTAGE D£TAILL£ES QUI
ACCOMPAGNENTCHAQUEKITDEMITREDOIVENTäTRELUESET
ASSIMIL£ESAVECCE'UIDEDINSTALLATION
!6%24)33%-%.4!VECTOUSLESSYSTáMES
D£VACUATIONUNCONDUITDROITDAUMOINSCM
DELONG$/)4äTRERATTACH£AUXCOLLETSDERACCORD
DE LAPPAREIL SAUF SI LE MODULE FACULTATIF N$
ESTUTILIS£SURLEMODáLE4IARA)
»L£MENTSDUSYSTáMEDEVENTILATION
,ES SYSTáMES DE VENTILATION UTILIS£S AVEC CET APPAREIL
DE CHAUFFAGE AU GAZ PEUVENT INCLURE UN DEUX OU TROIS
COUDESÜ,ESRAPPORTSENTRELESSECTIONSVERTICALES
ET LES SECTIONS HORIZONTALES DANS LES CONFIGURATIONS
UTILISANTDESCOUDESÜ
$/)6%.4
äTRERESPECT£S,ES
SCH£MAS ET TABLEAUX RELATIFS AU SYSTáME DE VENTILATION
INDIQUENT LES RAPPORTS ENTRE LES SECTIONS VERTICALES ET
LES SECTIONS HORIZONTALES6OIR LES SCH£MAS DES PAGES
SUIVANTES
)NSTALLATION
SUITE
&IGURE 6ENT#OMPONENTSAND4ERMINATIONS
6ENT3YSTEM4ERMITS
+ITSDEMITRES
&IGURE »L£MENTSDUSYSTáMEDEVENTILATIONETMITRES
SLK-01D
SLK-991D A o r ( ou)
SLK-980D
LINK-ST OVE
SLK-01TRD
HORIZONT AL
TERMINA TION
(MITRE
HORIZONT ALE)
WALL FIREST OP
(COUPE-FEU
MURAL)
90 DEGREE
ELBOW
(COUDE A 9 0 )
O
VERTICAL
TERMINA TION
(MITRE VERTICALE)
ST ORM COLLAR
(COLLIER
D’ORAGE)
ROOF FLASHING
(SOLIN)
HORIZONT AL PIPE
SUPPORT
(SUPPORT
DE
CONDUIT HORIZONT AL)
PIPE LENGTH
(SECTION
DE CONDUIT)
WALL BRACKET
(SUPPORT
MURAL)
CEILING
FIREST OP
(COUPE-FEU
DU
PLAFOND)
COMPONENT
IDENTIFICA TION
(IDENTIFICA TION
DES ELEMENTS)