23
WARNING: THE REAR FLUE COLLAR SEAL
CAP MUST REMAIN ATTACHED TO THE
REAR FLUE COLLARS IF THE FLUE SYSTEM
IS ATTACHED TO THE TOP STARTING COL-
LARS. SEE FIGURE 15.
Figure 15
B. Installing Flue Components
After determining which set of starting collars will be
used (top or rear), follow venting instructions accordingly.
Venting Out the Rear Flue
Remove the installed rear seal cap from the rear
starting collars by cutting the strap at each end (See
Figure 15). Follow the flue configuration tables
accordingly.
Remove the 127mm diameter heat shield from the 127mm
diameter collar by sliding it out.
WARNING: THE TOP HEAT SHIELD (INSIDE
THE FIREBOX) MUST REMAIN ATTACHED IF
THE FLUE SYSTEM IS ATTACHED TO THE REAR
STARTING COLLARS. SEE FIGURE 15.
Venting Out the Top Flue
Remove the top flue collar seal cap and the two pieces
of insulation inside the top two starting collars (see
Figure 15). Next remove the glass door.
Remove the 102mm diameter heat shield from the
102mm diameter collar by sliding it out.
You have to take the glass off again for positioning the
logs when the unit is finally installed in place and
finished around it. Re-install the glass door. Attach flue
system to the top starting collars.
WARNING: FAILURE TO REMOVE INSULA-
TION IN THE SET OF COLLARS YOU ARE
USING COULD CAUSE A FIRE.
WARNING: YOU MUST LEAVE THE INSULA-
TION IN PLACE IN THE SET OF COLLARS
YOU ARE NOT USING.
!
!
!
!
HEAT
SHIELD
DISCARD
INSULATION
SEAL
CAP
SEAL
CAP
HEAT
SHIELD
INSULATION,
DISCARD
BOTH
PIECES