20
Step 4. Positioning, Leveling, and
Securing the Fireplace
• Place the fireplace into position.
• Level the fireplace from side to side and from front to
back.
• Shim the fireplace with non-combustible material, such
as sheet metal, as necessary.
• Secure the fireplace to the framing by driving nails or
screws through the nailing tabs.
!
!
The diagram below shows how to properly position, level,
and secure the fireplace.
Figure 23. Proper Positioning, Leveling, and
Securing of a Fireplace
Figure 24. Gas Control System
Step 5. The Gas Control System
WARNING: THIS UNIT IS NOT FOR USE WITH
SOLID FUEL.
Intermittent Pilot Ignition (IPI) System
The gas control system used with this model is
Intermittent
Pilot Ignition (IPI).
This system includes a 3V control valve,
electronic module, and intermittent pilot.
WARNING: CONTINUOUS 110-120 VAC
SERVICE MUST BE WIRED DIRECTLY TO
THE FIREPLACE JUNCTION BOX.
NOTE: Flames too close to the ceramic insulators can
cause nuisance lockouts and electrode failure.
NAILING TABS
(BOTH SIDES)
PILOT
ASSEMBLY
3/16”