63
Heat & Glo • SL-5, SL-7, SL-9 Installation Manual • 2392-980 Rev. L • 6/17
G. Install Decorative Front
WARNING! Risk of Fire!
Install ONLY doors or fronts
approved by Hearth & Home Technologies. Unapproved
doors or fronts could cause fireplace to overheat.
This fireplace has been supplied with an integral
barrier to prevent direct contact with the fixed glass
panel. DO NOT operate the fireplace with the barrier
removed.
Contact your dealer or Hearth & Home Technologies if
the barrier is not present or help is needed to properly
install one.
For more information refer to the instructions supplied with
your decorative front.
Figure 11.7 Glass Assembly
F. Install Fixed Glass Assembly
WARNING! Risk of Asphyxiation!
Handle fixed glass
assembly with care. Inspect the gasket to ensure it is
undamaged and inspect the glass for cracks, chips or
scratches.
•
DO NOT
strike, slam or scratch glass.
•
DO NOT
operate fireplace with glass removed, cracked,
broken or scratched.
•
Replace as a complete assembly.
Replacing Fixed Glass Assembly
• Replace the glass door on the appliance. Pull out and
latch the four glass assembly latches into the groove on
the glass frame.
GLASS
ASSEMBLY
LATCHES
(BOTH BOTTOM
AND TOP)
2392-935C
4. Remove top left log from packaging. Place the log
into the indentation on the left rear log. The indenta
-
tion is highlighted
in Figure 6. The bottom two points
of the log will rest on the center hearth component.
See Figure 7.
Figure 7. Install Top Left Log
5. Remove small burner log from packaging. This log has
two holes on the bottom. These holes correspond to
two log pins located on the burner top. Place log on the
two log pins as shown Figure 8. When properly placed,
this log will rest on both the burner and the front hearth
component
.
Figure 8. Install Burner Log
Install Front Logs
6. Remove right top log from packaging. There is an
indentation located in the right rear log which “cradles”
the right top log. The indentation is highlighted in Figure
6. The burnt end of the log will engage a notch in the
middle hearth component
. See Figure 9.
Figure 9. Top Right Log Installed - Log Set Complete
BURNT END ENGAGED IN NOTCH