![Heat & Glo SL-5 Скачать руководство пользователя страница 29](http://html.mh-extra.com/html/heat-and-glo/sl-5/sl-5_installation-manual_2115417029.webp)
29
Heat & Glo • SL-5, SL-7, SL-9 Installation Manual • 2392-980 Rev. L • 6/17
Two Elbows
Figure 4.20
Rear Vent - Horizontal Termination - (continued)
Note
: Use DVP Series
components only.
H
1
H
2
V
1
H
1
MAX.
V
1
MIN.
H
2
MAX.
H
1
+ H
2
MAX.
1-1/2 ft.
457 mm
Back to back elbows
1 ft.
305 mm
2-1/2 ft.
762 mm
3 ft.
914 mm
1 ft.
305 mm
3 ft.
914 mm
6 ft.
1.8 m
5 ft.
1.5 m
3 ft.
914 mm
5 ft.
1.5 m
10 ft.
3.0 m
7 ft.
2.1 m
5 ft.
1.5 m
7 ft.
2.1 m
14 ft.
4.3 m
H
1
MAX. = 7 ft. (2.1 m)
H
1
+ H
2
MAX. = 14 ft. (4.3 m)
V
1
+ H
1
+ H
2
MAX. = 40 ft. (12.2 m)