21
Heat & Glo • LUX36, LUX42 Installation Manual
•
• 2287-980 Rev. L
2287-980 Rev. L • 4/16
Figure 4.8
Three Elbows
Note:
Flue restrictor is permit-
ted ONLY on 30 ft. minimum
vertical runs with no elbows.
H
2
H
1
V
2
V
1
LUX36
V
1
H
1
Maximum
V
2
H
2
2 ft
610 mm
17 in
432 mm
*
H
2
Max = 2 X V
2
3 ft
914 mm
2 ft
610 mm
*
H
2
Max = 2 X V
2
4 ft
1.2 m
4 ft
1.2 m
*
H
2
Max = 2 X V
2
5 ft
1.5 m
9 ft
2.7 m
*
H
2
Max = 2 X V
2
6 ft
1.8 m
12 ft
3.7 m
*
H
2
Max = 2 X V
2
7 ft
2.1 m
14 ft
4.3 m
*
H
2
Max = 2 X V
2
10 ft
3.0 m
20 ft
6.1 m
*
H
2
Max = 2 X V
2
V
1
+ H
1
must be adhered to.
* V
2
has no speci
fi
c restrictions EXCEPT,
V
total
+ H
total
cannot exceed 60 ft Maximum
LUX42
V
1
H
1
Maximum
V
2
H
2
4 ft
1.2 m
17 in
432 mm
*
H
2
Max = 2 X V
2
5 ft
1.5 m
2 ft
610 mm
*
H
2
Max = 2 X V
2
6 ft
1.8 m
9 ft
2.7 m
*
H
2
Max = 2 X V
2
7 ft
2.1 m
14 ft
4.3 m
*
H
2
Max = 2 X V
2
10 ft
3.0 m
20 ft
6.1 m
*
H
2
Max = 2 X V
2
V
1
+ H
1
must be adhered to.
* V
2
has no speci
fi
c restrictions EXCEPT,
V
total
+ H
total
cannot exceed 60 ft Maximum
WARNING! Risk of Fire!
• LUX36 requires a minimum of 24 inches of vertical venting before
attaching any elbow to the appliance.
• LUX42 requires a minimum of 48 inches of vertical venting before
attaching any elbow to the appliance.
DO NOT attach elbow directly to the appliance.
Top Vent - Horizontal Termination - (continued)