Heat & Glo LifeStyle Collection  •  Twilight-II  •  2087-900  Rev. G  •  12/05

4

B.    Glass Specifications

Hearth & Home Technologies appliances manufactured with
tempered glass may be installed in hazardous locations
such as bathtub enclosures as defined by the Consumer
Product Safety Commission (CPSC). The tempered glass
has been tested and certified to the requirements of 

ANSI

Z97.1

 and 

CPSC 16 CFR 1202 

(Safety Glazing Certification

Council 

SGCC# 1595

 and 

1597

. Architectural Testing, Inc.

Reports 

02-31919.01

 and 

02-31917.01

).

This statement is in compliance with 

CPSC 16 CFR Section

1201.5 

“Certification and labeling requirements” which refers

to 

15 

U.S. Code 

(USC) 2063 

stating “…Such certificate

shall accompany the product or shall otherwise be furnished
to any distributor or retailer to whom the product is delivered.”

Some local building codes require the use of tempered glass
with permanent marking in such locations. Glass meeting
this requirement is available from the factory. Please contact
your dealer or distributor to order.

A.

    Appliance Certification

NOTE:  

This installation must conform with local codes. In the

absence of local codes you must comply with the 

National

Fuel Gas Code, ANSI Z223.1-latest edition 

in the U.S.A.

and the 

CAN/CGA B149 Installation Codes 

in Canada.

NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.

This appliance is tested and approved as either supplemen-
tal room heat or a decorative appliance. It should not be fac-
tored as primary heat in residential heating calculations.

Listing and Code Approvals

F.    High Altitude Installations

U.L. Listed gas appliances are tested and approved without
requiring changes for elevations from 0 to 2000 feet in the
U.S.A. and Canada.

When installing this appliance at an elevation above 2000
feet, it may be necessary to decrease the input rating by
changing the existing burner orifice to a smaller size. Input
rate should be reduced by 4% for each 1000 feet above a
2000 foot elevation in the U.S.A., or 10% for elevations
between 2000 and 4500 feet in Canada. If the heating value
of the gas has been reduced, these rules do not apply. To
identify the proper orifice size, check with local gas utility.

If installing this appliance at an elevation above 4500 feet
(in Canada), check with local authorities.

E.    BTU Specifications

1

MODEL:   Twilight-II
LABORATORY: 
  Underwriters Laboratories, Inc. (UL)
TYPE: 
   Direct Vent Gas Appliance
STANDARD:
 ANSI Z21.50-2003•CSA2.22-M03•UL307B

Model

U.S. (0-2000 FT) or Canada (2000-4500 FT)

Input BTUH

Orifice Size

(DMS)

   Twilight II (NG)

US

38,000

32

CAN

34,200

33

   Twilight II (LP)

US

37,000

50

CAN

33,300

51

WARNING

Do NOT use this appliance if any part has been under
water. Immediately call a qualified service technician to
inspect the appliance and to replace any part of the control
system and any gas control which has been under water.

This product is listed to ANSI standards for “Vented Gas Ap-
pliances” and applicable sections of “Gas Burning Heating
Appliances for Manufactured Homes and Recreational Ve-
hicles”, and “Gas Fired Appliances for Use at High Altitudes”.

D.    Air Infiltration, Water Resistance and
       Structural Tests

The Hearth & Home Technologies Twilight-II Indoor/Outdoor
Appliance unit was tested to the following ASTM standards
at the Stork Twin City Testing laboratory.

Test Results

Model

Air Infiltration

(ASTM E283)

Water Resistance

(ASTM E331)

Structural Load

(ASTM E330)

 Twilight-II

  Indoor/Outdoor

0.07CFM/ft

2

No leakage @

8psf & 25psf

No Blowout

@ 75psf

C.    Thermal Performance Data

Model

Sound

Transmission

Class (STC)

Thermal Resistance

(R Value)

Thermal Conductivity

(K Value)

Twilight-II

27

0.08hr-sq ft-

O

F/BTU 12.5 BTU-in/hr-sq ft-

O

F

Í

Í

G. Non-Combustible Materials Specification

Material which will not ignite and burn  are those consisting
entirely of steel, iron, brick, tile, concrete, slate, glass or
plasters, or any combination thereof. Materials that are re-
ported as passing 

ASTM E 136, Standard Test Method

for Behavior of Materials in a Vertical Tube Furnace
at 750

o

C,

 shall be considered non-combustible materials.

H.  Combustible Materials Specification

Materials made of or surfaced with wood, compressed pa-
per, plant fibers, plastics, or other material that can ignite
and burn, whether flame proofed or not, or whether plastered
or unplastered shall be considered combustible materials.

Air infiltration test 

ASTM:E283-(04)

. The sample was test-

ed at 1.57 psf (equivalent to a 25-mph windload).
Water resistance test 

ASTM:E331-00

. The test specimen

was tested at the requested test pressures of 8.0 & 25.0 psf.
Structural test 

ASTM:E330-02

. The unit was tested to a

design pressure of 50-psf, a test pressure of 75-psf.

Содержание Twilight-II

Страница 1: ...ARNING Keep children away CAREFULLY SUPERVISE children in same room as appliance Alert children and adults to hazards of high temperatures Do NOT operate with protective barriers open or removed Keep...

Страница 2: ...ertinent information about your appliance Gas and Electric Information Model Number Serial Number Type of Gas The model information regarding your specific appliance can be found on the rating plate u...

Страница 3: ...Certification 4 B Glass Specifications 4 C Thermal Performance Data 4 D Air Infiltration Water Resistance and Structural Tests 4 E BTU Specifications 4 F High Altitude Installations 4 G Non Combustib...

Страница 4: ...ation above 4500 feet in Canada check with local authorities E BTU Specifications 1 MODEL Twilight II LABORATORY Underwriters Laboratories Inc UL TYPE Direct Vent Gas Appliance STANDARD ANSI Z21 50 20...

Страница 5: ...ing tools and building supplies are available Reciprocating saw Framing material Pliers Hi temp caulking material Hammer Gloves Phillips screwdriver Framing square Flat blade screwdriver Electric dril...

Страница 6: ...ffic areas A Selecting Appliance Location When selecting a location for your appliance it is important to consider the required clearances to walls see Figure 3 1 Figure 3 1 Appliance Locations Model...

Страница 7: ...Prevent contact with sagging or loose insulation WARNING C A B Note Framing dimensions as sume use of 1 2 inch thick wall covering materials on exterior of framing only and NO sheet rock on interior...

Страница 8: ...learances to Mantels or other Combustibles above Appliance Figure 3 5 Indoor clearances to Mantel Legs or Wall Projections Acceptable on both sides of opening 12 11 10 9 8 7 6 13 5 8 12 5 8 11 5 8 10...

Страница 9: ...additional termination caps Q 9 feet 1 2 x Q ACTUAL RMAX 2 caps plus appliance x QACTUAL D E L FP A H M X J or K I A G F FP FP FP FP FP B B B 60 minimum for vinyl clad soffits a appliance shall not o...

Страница 10: ...all against vapor barriers or exposed insulation WARNING Do NOT notch into the framing around the appliance spacers CAUTION A Securing and Leveling the Appliance Appliance Preparation 5 Figure 5 1 Pos...

Страница 11: ...non combustible for a minimum of 12 inches above and on both sides of the exterior face of the appliance This non combustible finishing material can be up to a maximum of 6 inches thick 6 inches maxi...

Страница 12: ...iance provided the hole in the outer wrap does NOT exceed 2 1 2 inches in diameter and does not penetrate the firebox NOTE A listed and Commonwealth of Massachusetts ap proved 1 2 inch 13mm T handle m...

Страница 13: ...n Canada check with local authorities Ensure that gas line does not come in contact with outer wrap of appliance Follow local codes Incoming gas line should be piped into the valve com partment and co...

Страница 14: ...override IPI safety lockout and may cause explosion This appliance may be used with a wall switch wall mounted thermostat and or a remote control If using thermostat use one compatible with a millivol...

Страница 15: ...o gas line installation Figure 7 1 Fan Wiring Diagram C Optional Accessories Optional fan and remote control kits require that 110 120 VAC be wired to the factory installed junction box before the app...

Страница 16: ...n box It is highly recommended that the junction box be installed at this time to avoid reconstruction The battery pack requires two D cell batteries not included CAUTION Battery polarity must be corr...

Страница 17: ...ound wires to the junc tion box as shown Add a 1 4 inch insulated female connector to the red switch leg wire route it through the knock out in the face of the junction box and connect to the top fan...

Страница 18: ...D NON COMBUSTIBLE BOARD SUPPLIED ON APPLIANCE Note Measurements are in inches Interior View MEASURED FROM CORNER FIREPLACE HOOD IN TOP VIEW B Facing Material Fire Risk Do NOT obstruct air inlet or out...

Страница 19: ...sing only a 300o F minimum sealant Figure 8 3 Exterior View COMBUSTIBLE SHEATHING HOUSEWRAP NON COMBUSTIBLE SHEATHING NON COMBUSTIBLE FACING 6 INCH MAXIMUM PROJECTION FROM FACE OF APPLIANCE 6 IN MAX R...

Страница 20: ...inimum of 12 inches above and on both sides of the exterior face of the appli ance This non combustible finishing ma terial can be up to a maximum of 6 inches thick 6 inches maximum horizontal over ha...

Страница 21: ...er placement instructions in manual Do NOT place embers directly over burner ports Replace ember material annually Explosion Risk WARNING Improperly placed embers interferes with proper burner operati...

Страница 22: ...the indents on the bottom side of the log to position the large end of the log onto the grate tine as shown Position the thin end of log 1 one inch from port pattern as shown STEP 3 LOG 2 SRV2005 700...

Страница 23: ...cover any port holes STEP 5 LOG 4 SRV2005 703 Locate the sharp notch on log 4 against the grate tine as shown The smooth cutout on log 4 should rest on the burner surface As with log 3 be careful not...

Страница 24: ...t to ensure it is undamaged Inspect the glass for cracks chips or scratches WARNING Do NOT strike slam or scratch glass Do NOT clean glass with a razor blade Do NOT operate appliance with glass door r...

Страница 25: ...injury or property damage Refer to the owner s information manual provided with this appliance For assistance or additional information consult a qualified installer service agency or the gas supplier...

Страница 26: ...service or maintenance can cause injury or property dam age Refer to the owner s informa tion manual provided with this ap pliance This appliance needs fresh air for safe operation and must be in stal...

Страница 27: ...plug or remove batteries from remote control if absent or if appliance will not be used for an extended period of time Property damage possible from elevated temperatures CAUTION Fire Hazard Keep comb...

Страница 28: ...ction on module with ON OFF switch in ON position Acceptable readings of a good transformer are between 3 2 and 2 8 volts AC b A shorted or loose connection in wiring configuration or wiring harness R...

Страница 29: ...h to OFF position Remove ignitor wire I from module Place ON OFF Rocker switch or wall switch in ON position Hold ground wire about 3 16 inch away from I terminal on module If there is no spark at I t...

Страница 30: ...umes Odors Handle glass assembly with care NOTE Clean glass after initial 3 4 hours operation Longer operation without cleaning glass may cause a permanent white film on glass CAUTION When cleaning gl...

Страница 31: ...and repaint as necessary 2 Replace appliance if firebox has been perforated Burner Ignition and Operation 1 Verify burner is properly secured and aligned with pilot or igniter 2 Clean off burner top i...

Страница 32: ...7 D 43 1091 M 40 3 4 1036 E 1 2 13 N 42 1 8 1070 F 40 3 4 1035 O 23 1 2 597 G 3 3 8 86 P 35 5 8 904 H 2 1 2 64 Q 24 610 I 4 1 2 114 A Appliance Dimension Diagram Dimensions are actual appliance dimens...

Страница 33: ...I 2087 900 Rev G 12 05 33 Part number list on following page NG LP Exploded Parts Diagram B Service Parts Twilight II Beginning Manufacturing Date 6 05 Ending Manufacturing Date ___ 10 Log Set Assembl...

Страница 34: ...ly LOGS TWI 11 Log 1 SRV2005 701 12 Log 2 SRV2005 700 13 Log 3 SRV2005 702 14 Log 4 SRV2005 703 15 Log 5 SRV2005 704 16 Log 6 SRV2077 701 17 Log 7 SRV703 703 Lava Rock Bag 2005 790 Mineral Wool 050 72...

Страница 35: ...e Assembly 593 590A 5 Pilot Assembly NG 2090 012 5 Pilot Assembly LP 2090 013 6 Valve L Bracket 674 168 7 Burner Orifice NG 32C 582 832 7 Burner Orifice LP 50C 582 850 8 Valve Bracket 2087 117 9 Flex...

Страница 36: ...he Product or added thereafter are NOT covered by this warranty unless expressly authorized and approved by HEAT GLO in writing 6 Any damages caused by environmental conditions inadequate ventilation...

Страница 37: ...ation Please contact your Heat Glo dealer with any questions or concerns For the number of your nearest Heat Glo dealer please call 1 888 427 3973 Printed in U S A Copyright 2005 DO NOT DISCARD THIS M...

Отзывы: