background image

2

READ 

and 

UNDERSTAND 

all instructions

carefully before starting the installation. 

FAILURE

TO FOLLOW 

these installation instructions may

result in a possible fire hazard and will void the

warranty.

Prior to the first firing of the fireplace, 

READ 

the

Using Your Fireplace section of the 

Owners Guide

.

DO NOT USE 

this appliance if any part has been

under water. Immediately 

CALL 

a qualified

service technician to inspect the unit and to

replace any part of the control system and any

gas control which has been under water.

THIS UNIT IS NOT FOR USE WITH SOLID FUEL.

Installation and repair should be 

PERFORMED

by a qualified service person. The appliance and

venting system should be 

INSPECTED 

before

initial use and at least annually by a professional

service person. More frequent cleaning may be

required due to excessive lint from carpeting,

bedding material, etc. It is 

IMPERATIVE 

that the

unit’s control compartment, burners, and

circulating air passageways 

BE KEPT CLEAN

to provide for adequate combustion and ventilation

air.

Always 

KEEP 

the appliance clear and free from

combustible materials, gasoline, and other

flammable vapors and liquids.

LIRE ATTENTIVEMENT 

et bien 

COMPRENDRE

toutes les instructions avant d’entreprendre

l’installation. 

LE NON-RESPECT DE CES

instructions d’installation peut provoquer un

incendie et annule la garantie.
Avant le premier allumage de la cheminée, 

LIRE

LA SECTION 

Fonctionnement de la cheminée dans

le manuel de l’utilisateur.

NE PAS SE SERVIR 

de cet appareil s’il a été

plongé dans l’eau, complètement ou en partie.

APPELER

 un technicien qualifié pour inspecter

l’appareil et remplacer toute partie du système de

contrôle et toute commande qui ont été plongées

dans l’eau.

CET APPAREIL NE PEUT PAS ÊTRE UTILISÉ

AVEC DU COMBUSTIBLE SOLIDE.
FAIRE EFFECTUER 

l’installation et la réparation

de l’appareil par un technicien après-vente qualifié.

Faire

 INSPECTER

 

l’appareil et la ventilation avant

la première utilisation, et les faire nettoyer ensuite

au moins une fois par an par une personne qualifiée.

Effectuer le nettoyage plus fréquemment si des

tapis, de la literie, etc..., produisent des peluches

en quantité excessive. Il est 

IMPÉRATIF 

que le

compartiment des réglages de l’appareil, les brûleurs

et le système de ventilation 

SOIENT TOUJOURS

PROPRES 

pour assurer un volume suffisant d’air

de combustion et de ventilation.
Veiller à 

NE JAMAIS

 laisser de matériaux

inflammables à proximité de l’appareil.

!

!

!

                SAFETY AND WARNING

               INFORMATION

!

!

!

!

WARNING: Improper installation, ad-

justment, alteration, service or mainte-

nance can cause injury or property

damage.  Refer to this manual.
For assistance or additional informa-

tion consult a qualified installer, service

agency or the gas supplier.
Read this manual before installing or

operating this appliance. This 

Installers

Guide 

must be left with appliance for

future reference.

AVERTISSEMENT: Une installation, un

réglage, une modification, un entretien

ou une maintenance incorrects peuvent

entraîner des blessures ou dommages

matériels. Consulter le manuel.
Pour toute assistance ou pour obtenir

de plus amples informations, consulter

un installateur qualifié, un service après-

vente ou le fournisseur de gaz.
Lire ce manuel avant d’installer ou de

fairé fonctionner cet appareil. Ranger ce

Guide D’installation

 à proximité de

l’appareil pour pouvoir le consulter en

cas de besoin.

!

!

!

!

!

!

!

CONSIGNES DE SÉCURITÉ

Содержание AT-GRAND-D

Страница 1: ...ervir des t l phones se trouvant dans le b timent o vous vous trouvez vacuez la pi ce le b timent ou la zone Appelez imm diatement votre fournisseur de gaz depuis un voisin Suivez les instructions du...

Страница 2: ...i pour inspecter l appareil et remplacer toute partie du syst me de contr le et toute commande qui ont t plong es dans l eau CET APPAREIL NE PEUT PAS TRE UTILIS AVEC DU COMBUSTIBLE SOLIDE FAIRE EFFECT...

Страница 3: ...evant de l appareil soit toujours D GAG de tout obstacle pour permettre l entretien et assurer un fonctionnement correct Etant donn sa temp rature lev e installer l appareil L CART des zones de passag...

Страница 4: ...taining and Servicing Your Appliance 27 Table of Contents Consignes de s curit 2 Liste des pieces de rechange 5 Section 1 Homologations et codes d installation 7 Homologation et codes 7 Certifications...

Страница 5: ...ed sitting room in the U S A and Canada 1Approvals and Codes Approval Listing and Codes Homologations et codes d installation Homologations et codes L appareil Certification Les mod les Heat N Glo pr...

Страница 6: ...or assistance in determining the proper orifice for your location Approvals and Codes continued Installations haute altitude Les appareils de chauffage au gaz homologu s U L ont t test s et approuv s...

Страница 7: ...entation de l Appareil Gaz Heat N Glo Les chemin es gaz Heat N Glo ventilation directe sont con ues pour aspirer l air de combusion de l ext rieur et refouler les gaz d chappement l ext rieur Sauf avi...

Страница 8: ...in es fabriqu es en usine qui ont t install es conform ment tous les codes de construction en vigueur nationaux r gionaux et locaux 2 Les ouvertures minimum requises pour la chemin e sont indiqu es la...

Страница 9: ...E LARGEUR AVANT 839 mm 33 in LARGEUR ARRI RE 610 mm 24 in PROFONDEUR 346 mm 13 5 8 in HAUTEUR 618 mm 24 5 16 in REMARQUE Si le collier d chappement de l appareil de chauffage et le registre de la che...

Страница 10: ...s figures 3 4 et 5 REMARQUE La hauteur verticale minimum conduit d chappement est de 4 2 m 14 ft et la hauteur verticale maximum est de 15 m 50 ft Mesurer ces dimensions partir des colliers de d part...

Страница 11: ...gueur de conduit de ventilation flexible d un diam tre de 7 62 cm 3 in pour l air de combustion un 1 raccord du conduit la mitre et une 1 mitre pour conduit vertical SLK 991DA ou SLK 980D REMARQUE Il...

Страница 12: ...un b timent Installing the Insert continued Figure 2 Minimum Height from Roof to Lowest Discharge Opening ROOF PITCH H MIN FT Flat to 6 12 1 0 6 12 to 7 12 1 25 Over 7 12 to 8 12 1 5 Over 8 12 to 9 12...

Страница 13: ...SSEMENT NE RACCORDER LE CONDUIT D CHAPPEMENT QU AU COLLIER DE D PART D CHAPPEMENT ET AU COLLIER CENTRAL DE LA MITRE NE RACCORDER LE CONDUIT D ADMISSION D AIR QU AU COLLIER D ADMISSION D AIR ET LE FIXE...

Страница 14: ...Figure 4 Figure 5 INLET AIR STARTING COLLAR COLLIER DE D PART D ADMISSION D AIR EXHAUST STARTING COLLAR COLLIER DE D PART D CHAPPEMENT TERMINATION CAP MITRE ADAPTOR ADAPTATEUR INLET AIR COLLAR COLLIER...

Страница 15: ...ENT DANS UN SYST ME MILLIVOLTS NEPASRACCORDERUNEVANNE DE COMMANDE SUR 110 120 VCA Step 2 Positioning Leveling and Securing Insert Installing the Insert continued 1 Place the insert into position 2 Lev...

Страница 16: ...all conform ment aux codes de construction locaux L installation doit tre effectu e par un technicien qualifi et ou muni d une licence de mani re respecter les r glements municipaux REMARQUE Purger la...

Страница 17: ...test pressures equal to or less than one half 1 2 psig 3 5 kPa Installing the Insert continued Step 5 Gas Pressure Requirements tape 5 Sp cifications relatives la pression du gaz Une d rivation de vi...

Страница 18: ...e par veilleuse Sp cifications Cet appareil NE DOIT PAS tre raccord une source de courant 110 120 V CA pour fonctionner ADVERTISSEMENT NE PAS RACCORDER LA VANNEDECOMMANDESUR110 120VCAPOUR VITER UN MAU...

Страница 19: ...iagram Installation suite Figure 9 Sch ma de c blage du ventilateur NOTE IFANY OF THE ORIGINALWIRE AS SUP PLIED WITH THE APPLIANCE MUST BE RE PLACED IT MUST BE REPLACED WITH TYPE 1050 C RATED WIRE REM...

Страница 20: ...s door Replace the trim door Installing the Insert continued Installation suite Positionnement des b ches Si les b ches sont mont es d usine il est inutile de les repositionner Si les b ches sont livr...

Страница 21: ...e unit Figure 10 Glass Assembly Figure 11 Placement of the Ember Material 1 Soulever l encadrement de la porte et le retirer 2 Desserrer les attaches et d poser la porte Figure 10 Porte en verre Figur...

Страница 22: ...o outer right side of the insert See Figure 12 2 Disconnect the ON OFF switch from the low voltage wire leads and insert the ON OFF switch through the hole at the upper right corner of the surround it...

Страница 23: ...ncher les fils de basse tension l interrupteur MARCHE ARR T 4 D poser et mettre de c t les quatre vis de fixation de l encadrement aux quatre coins de l avant de l appareil voir la figure 12 5 Glisser...

Страница 24: ...URE REFERENCE Avant d allumer l appareil de chauffage au gaz ne pas oublier de Relire et assimiler les consignes de s curit Relire la section Consignes de s curit au d but de ce Guide d installation V...

Страница 25: ...retien Bien que la fr quence d entretien et de r vision de la chemin e d pende du volume d utilisation et du type d installation nous recommandons un examen de l appareil par un technicien qualifi au...

Страница 26: ...r de nettoyants abrasifs Entretien et r vision suite Figure 14 Burner Flame Patterns Make sure the flames are steady not lifting or floating S assurer que les flammes sont stables qu elles ne montent...

Отзывы: