Hearthstone Quality Home Heating Products, Inc
®
Bari Model 8171
6
1. This solid-fuel-fired appliance does not draw
steadily, smoke rollout occurs, fuel burns
poorly, or back-drafts occur whether or not
there is combustion present.
2. Existing fuel-fired equipment in the house,
such as fireplaces or other heating
appliances, smell, do not operate properly,
suffer smoke roll-out when opened, or back-
draft whether or not there is combustion
present.
3. Opening a window slightly on a calm
(windless) day alleviates any of the above
symptoms.
4. The house is equipped with a well-sealed
vapor barrier and tight fitting windows and/or
has any powered devices that exhaust house
air.
5. There is excessive condensation on windows
in the winter.
6. A ventilation system is installed in the house.
If these or other indications suggest that infiltration air
is inadequate, additional combustion air should be
provided from the outdoors. Outside combustion air
can be provided to the appliance by using the optional
outside air kit #91-53500 / #91-53700.
P
ERIODIC
C
HECKLIST
Perform each of these tasks at least at the specified
intervals.
At the End of Every Week:
•
Empty ashes from the firebox and ash pan,
sooner if the firebox or the ash pan is full.
At the Beginning of Every Other Month:
•
Depending upon your use of the stove, visually
inspect the chimney connector and chimney for
creosote. (Please see page 37)
•
Check door seals using the "dollar bill test." -
When the stove is cool, shut the door on a dollar
bill. If the bill pulls out without any resistance,
then your stove’s door is not sealing properly. To
tighten the seal, adjust the door latch
mechanism or change the door gasket. (Refer to
page 37.)
At the End of Every Season:
•
Dismantle the chimney connector and clean it
thoroughly. Replace any pieces that show signs
of rust or deterioration.
•
Inspect and, if necessary, clean your chimney.
•
Thoroughly clean out the inside of the stove.
•
Inspect all door gasket material and replace if
worn, frayed, cracked or extremely hard.
•
Inspect and replace cracked or damaged
vermiculite panels.
E
MERGENCY
P
ROCEDURES
If you have a stovepipe or chimney fire, follow
these instructions:
1. If the fire is too threatening, leave the area and
call the fire department immediately! If not,
perform the next three steps.
2. Close the primary air control.
3. Close the stovepipe damper (if present).
4. Keep the stove front door and ash pan closed!
•
WARNING: DO NOT ATTEMPT TO PUT OUT A
STOVEPIPE OR CHIMNEY FIRE BY THROWING
WATER ONTO THE STOVE, STOVEPIPE, OR
CHIMNEY. THE EXTREMELY HIGH
TEMPERATURE OF SUCH FIRES CAN CAUSE
INSTANTANEOUS STEAM AND SERIOUS BODILY
HARM.
Once the chimney fire expires, leave the primary air
control closed and let the fire in the stove die out
completely. Inspect the stove, stovepipe, and
chimney thoroughly for any sign of damage before
firing the stove again. You must correct any damage
before using your stove again.