Hearthstone Quality Home Heating Products, Inc
®
Bari Model 8171
45
T
ROUBLESHOOTING
G
UIDE
PROBLEM
POSSIBLE CAUSE
SOLUTIONS
STOVE SMOKES
Operating Technique
Fully open the primary air control one minute before
opening doors.
Cold Chimney
Preheat the chimney when first starting a fire. Briefly open a
window in the room containing the stove.
Blocked Chimney
Examine the chimney and stovepipe for blockage or
creosote accumulations.
Oversized Chimney
Reline the chimney to the appropriate diameter
Undersized Chimney
Install a draft inducer or replace the chimney.
Chimney Too Short
Lengthen the chimney.
Air Infiltration Into The
Chimney
Seal chimney connections and openings such as clean-out
doors.
More Than One
Appliance Connected to
the Flue
Disconnect all other appliances and seal openings.
BACK-PUFFING
OR GAS
EXPLOSIONS
Operating Technique
Fully open the primary air control one minute before
opening the door and keep it fully open for a few minutes
after reloading.
Extra Low Burn Rate
Burn the stove at a higher burn rate.
Chimney Down-draft
Install a chimney cap.
Excessive Ash Build-up
Empty the ash pan more frequently. Increase efficiency of
burns, and avoid using poor quality or green wood.
UNCONTROLLED
OR SHORT BURN
Unsealed or Open Door
Open ash grate
Close the door tightly or replace the gaskets.
Slide ash grate to closed position.
Excessive Draft
Check the installation. Operate at LOW BURN. Install
stovepipe damper.
Extra Long Chimney
Shorten the chimney. Install stovepipe damper(s).
Oversized Chimney
Reline the chimney to the proper diameter.
High Winds or Hilltop
Location:
Install a chimney cap.
Excessive Draft
Draft in excess of 0.1 WC should be corrected with a
stovepipe damper(s)
INSUFFICIENT
HEAT
Poor Quality or Green
Wood
Use only air-dried wood, preferably dried at least one year.
Low Burn Rate
Operate the stove at a higher burn rate.
Air Insulated Chimney
Replace with a pre-fabricated insulated chimney system or
a properly sized masonry chimney.
Cold Exterior Chimney
Reline or insulate the chimney.
Leaky Stovepipe or
Chimney
Check the installation.
Too Much Heat Loss
From House
Add insulation, use energy efficient windows, or caulk
windows, and seal openings in home.
Excessive Ash Build-up
Empty the ash pan more frequently. Increase efficiency of
burns, and avoid using poor quality or green wood.
BLISTERING OF
FINISH
Operating Technique
Do not over-fire the stove. Monitor stove temperatures. Use
seasoned wood only.
Excessive Draft
Check the DRAFT. A damper may be required. Operate the
stove at a LOW BURN range.