18
Figure 16
WARNING: FAILURE TO REMOVE
INSULATION IN THE SET OF COL-
LARS YOU ARE USING COULD
CAUSE A FIRE.
WARNING: THE REAR FLUE COL-
LAR SEAL CAP MUST REMAIN AT-
TACHED TO THE REAR FLUE COL-
LARS IF THE FLUE SYSTEM IS AT-
TACHED TO THE TOP STARTING
COLLARS. SEE FIGURE 16.
WARNING:YOU MUST LEAVE THE
INSULATION IN PLACE IN THE
SET OF COLLARS YOU ARE NOT
USING.
FLUEING OUT REAR
FLUEING OUT TOP
Vertical Flue Restrictor
If the heater installation requires a vertical flue exceeding 4.5m above the unit a vertical flue restrictor
must be installed. See instructions with the SRV-VBFFL kit.
Installing Flue Components
After determining which set of starting collars will be
used (top or rear), follow flueing instructions
accordingly.
Flueing Out the Rear Flue
Remove the rear collar seal cap by cutting the
strap at each end (See Figure 16).
Next, remove the insulation from the rear flue, pull
the heat shield out from outside of the heater.
WARNING: THE TOP FLUE COLLAR
SEAL CAP MUST REMAIN ATTACHED
TO THE TOP FLUE COLLAR IF THE FLUE
SYSTEM IS ATTACHED TO THE REAR
STARTING COLLARS. SEE FIGURE 16.
Flueing Out the Top Flue
Remove the two screws in the top collar seal cap.
Remove the seal cap and both pieces of insulation
in the top collars (See Figure 16). Remove the
heat shield inside the top collars from the outside
of the heater.
!
!
!
!
Insert screwdriver
or similar object
here to remove cap.
CUT
HERE