![Hearth Technologies Heat-N-Glo SL-550TRS-AU Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/hearth-technologies/heat-n-glo-sl-550trs-au/heat-n-glo-sl-550trs-au_installation-and-operation-instructions-manual_2114560017.webp)
17
FIGURE 15
FLUEING WITH THREE (3) 90° ELBOWS
1´ MIN. (.3M)
2´ MAX. (.6M)
4´ MAX. (1.2M)
2´ MIN. (.6M)
4´ MAX. (1.2M)
8´ MAX. (2.4M)
3´ MIN. (.9M)
6´ MAX. (1.9M)
12´ MAX. (3.6M)
4´ MIN. (1.2M)
8´ MAX. (2.4M)
16´ MAX. (4.8M)
H = 8´ MAX. (2.4M) H+H
1
= 16´ MAX. (4.8M)
NOTE: V + V, + H + H
1
= 30 (9.1M) MAX.
V (FT.) H (FT.) H + H
1
(FT.)
V (FT.) H (FT.) H + H
1
+ H
2
(FT.)
1´ MIN. (.3M)
2´ MAX. (.6M)
4´ MAX. (1.2M)
2´ MIN. (.6M)
4´ MAX. (1.2M)
8´ MAX. (2.4M)
3´ MIN. (.9M)
6´ MAX. (1.9M)
12´ MAX. (3.6M)
4´ MIN. (1.2M)
8´ MAX. (2.4M)
16´ MAX. (4.8M)
V + H + H
1
+ H
2
= 30´ MAX. (9.1M) H = 8´ MAX. (2.4M) H + H
1
+ H
2
= 16´ MAX. (4.8M)
FLUEING WITH THREE (3) 90° ELBOWS
USE D-SERIES
COMPONENTS ONLY.