20
7034-276E
October 13, 2015
MT. VERNON AE
H. Error Codes
If a system error occurs that forces the system to stop op-
erating an error screen appears. Depending upon the error
type, up to three retry attempts are allowed after which a
service professional is required.
Press the ERROR LIST button to display the latest error.
See
page 27
for a list of error codes.
G. Service Information
The SERVICE INFORMATION screen displays contact in-
formation for Hearth & Home Technologies Customer Ser-
vice Line. The local dealer may have changed this upon or
before the installation to indicate a dealer hot line.
www.quadrafire.com
to locate your nearest
dealer
DONE
ERROR LIST
Figure 20.2
MANUAL LIGHT PROCEDURE
Press “CONTINUE”
button to start manual
lighting sequence
Current Tem: 72 F
O
CONTINUE
MANUAL LIGHT PROCEDURE
Please wait while
feed charge is loading
into firepot
MANUAL LIGHT PROCEDURE
Open door...
Manually light fuel...
Close door
Figure 20.1
13 Volts
12 Volts
11 Volts
Battery
Below
10 Volts
The appliance has been designed to operate on an optional
battery back-up system.
If you have frequent power outages in your region, hook
the appliance up to a 12 volt battery and it will automatically
switch to battery power in the event of a power failure. The
12 volt power cord sold as a separate accessory does not
charge the battery.
Figure 20.3
MAINT BURN
73
Set at: 73
12:30 PM
HEAT OUTPUT
MENU
“Maint Burn” will display when
the thermostat has reached the
set room temperature and will
run on low until it reaches its
auto-clean cycle time.
Battery icon.
Figure 20.4
Wall Control Display
The wall control will display the battery icon when operating
in the battery back-up mode.
Figure 20.4.
I. Battery Back-up System (Optional)
• Hook up to battery terminals BEFORE you plug battery
into appliance.
• Damage to internal electronic components may occur
CAUTION
Refer to
owners manual for instructions on how to attach the
cable to appliance. The following are screens you will see
when using a back-up battery.
Operating on Battery Back-Up
•
A battery icon appears on your wall control to let you know
you are now operating on battery power.
Figure 20.3.
• Fire must be manually lit as the appliance will no longer
automatically light.
•
Use only approved fi re starting gel to start fi re.
• High burn rate is no longer available on battery back-up.
• E
ach level drops down one level, i.e
the high burn be-
comes medium-high burn and so on.
• If the battery charge falls below 10 volt it can no longer
sustain the appliance operation and the appliance will
shut down. You must disconnect and reconnect the bat-
tery to start it up again.
Recommended Battery
• 12 volt deep cycle battery, (i.e., marine or RV type).
•
A 12 volt battery cable is available through your local
dealer.
WARNING
Risk of Injury!
• Blowers may continue to run and would be exposed to
human contact.