background image

October 13, 2015 

 

 

              

7034-276E 

 

 

 

         

                  15

MT. VERNON AE

b.  Manual 

In MANUAL cycle, the heat output remains the same 
regardless of the difference between the set and room 
temperatures. The wall control will function as a simple 
on/off thermostat. When the system is set to MANUAL 
the HEAT OUTPUT selection is added in the lower right 
corner.    

Press the button under this selection to access this fea-
ture.  The HEAT OUTPUT screen is used to set the level 
of heat produced whenever the wall control calls for heat. 

Figure 15.3. 

The HEAT OUTPUT screen is not accessible 

in AUTOMATIC cycle.

AUTO/MANUAL SETTINGS

Manual

Off

Automatic

Manual

Medium

AUTO/MANUAL SETTINGS

Automatic

Manual
Off

Figure 15.1

Figure 15.2

Figure 15.3

3.  Fuel Type

The FUEL TYPE screen is used to select the fuel that will be 
used with the pellet system. The list on this screen indicates 
all fuel choices available to burn in the appliance. 

NOTE:  The list of fuels can be updated by your local 
dealer as they become available.

Figure 15.5

c.  OFF 

This selection turns the appliance off.  When the appli-
ance is set to OFF, it will not light regardless of room tem-
perature.  Use this setting when cleaning and maintaining 
your appliance.

Manual

Off

Automatic

Figure 15.4

To select a fuel type, use the UP/DOWN buttons to scroll to 
the desired fuel type and then press the button under “Se-
lect”.  The arrow will change to indicate the currently select-
ed fuel.

NOTE

:  If you are burning a high ash fuel set the fuel selec-

tion to “Utility Pellets”. 

When purchasing corn or wheat to burn in your appliance, 
read the ingredient label very carefully.  

Do NOT purchase 

fuel that contains any additives

 such as oils (i.e. soybean 

oil) and meals as it will result in poor appliance performance.  

If you are buying corn or wheat the only ingredient that should 
be listed is corn or wheat.

4.  Program (7 Day Programming)

The wall control is pre-programmed at 68

o

F for all time set-

tings.  It will remain there until it is re-programmed.

The wall control can be programmed as a setback thermo-
stat.  Each day of the week has four program periods. The 
wall control menus have some features that make it easy to 

Monday

Full Week

Mon-Fri

Sat-Sun

PROGRAMMING RANGE

Figure 15.6

Sunflower Seeds

Corn
Utility Pellet
Softwood Pellet

Wheat
Hardwood Pellet

DONE

SELECT

FUEL SELECTION

a.  Full Week

NOTE: 

 It is important to note that the most recent program-

ming entry will override all previous programming for an indi-
vidual day or range of days.

The small triangle on the left side indicates the current active 
programming line.  

Figure 15.6.

  For each of the four inter-

vals available to program there are three adjustable values: 
set hour, set minutes and set temperature.  You will need to 
increase or decrease the hour to change from AM to PM.

program groups of days alike.  This minimizes the number 
of steps required to program the wall control for most appli-
cations. 

To access the programming screen, select Program from 
the menu screen and then select the desired programming 
range from the PROGRAMMING RANGE screen.

Содержание QUARDA-FIRE MTVERNON-AE-CSB

Страница 1: ...terials away WARNING If the information in these instruc tions is not followed exactly a fire may result causing property damage personal injury or death Do not store or use gasoline or other flam mab...

Страница 2: ...tions OMNI Test Laboratories Le Conseil Canadien des Normes CCN SCC l Institue des Standards Nationaux Am ricain ANSI et l Agence de Protection Environnemental EPA Puissance de Rendement 53 300 Btu s...

Страница 3: ...Fire Characteristics Flame Height Adjustment 9 J Clear Space 10 K Ignition Cycles 10 L Frequently Asked Questions 12 3 Wall Control Operating Instructions13 A Introduction 13 B Language Selection 13...

Страница 4: ...tion warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distributor whichever occurs earlier Th...

Страница 5: ...E 5 MT VERNON AE WARRANTY CONDITIONS This warranty is void if LIMITATIONS OF LIABILITY 8 K N N OQ R U Z 8 88 U 8 U Q 8 N N Q Z R N U Q 8 R Z N N 88 N U Q 8 N O K WARRANTY EXCLUSIONS N Z N _ q _ q _ q...

Страница 6: ...hazard WARNING Fire Risk Hearth Home Technologies disclaims any responsibility for and the warranty will be voided by the following actions B BTU Efficiency Specifications C Glass Specifications This...

Страница 7: ...fuels Depending on the source material it may have a high or low ash content Higher Ash Content Material Hardwoods with a high mineral content Fuel that contains bark Standard grade pellets high ash...

Страница 8: ...be stored in a tight container to prevent it from absorbing moisture from damp or wet floors This will also prevent rodents from becoming a problem Do not store any pellet fuel within the clearance r...

Страница 9: ...couple cover or missed ignitions can occur G Filling the Hopper with Fuel Check the hopper and make sure it is empty before filling with fuel Open the cast top hopper lid Do not over fill the hopper T...

Страница 10: ...e are two choices in the Automatic Manual menu of how your appliance will operate Automatic Mode The wall control will turn the heat output level up or down depending on how far the room temperature i...

Страница 11: ...auto clean cycle is initi ated the appliance will revert to shutdown cycle The floor of the firepot will open and dump the ash into the ash pan It takes approximately 2 minutes to complete the au to c...

Страница 12: ...h black tails and is lazy 4 The flame height adjustment needs to be reduced or the firepot needs cleaning Heat exchanger or exhaust blower needs cleaning 5 Excessive smoky start up 5 Either the firepo...

Страница 13: ...rent status of the system It indicates if the system is running in automatic or manual cycle if it is turned on or off and where it is in the operating sequence a START UP Indicates that the appliance...

Страница 14: ...not work call your dealer E The Main Menu The menu is the heart of customizing the operation of the pellet appliance system to your personal liking The choices on this menu are 1 Set Comfort Level Te...

Страница 15: ...u are burning a high ash fuel set the fuel selec tion to Utility Pellets When purchasing corn or wheat to burn in your appliance read the ingredient label very carefully Do NOT purchase fuel that cont...

Страница 16: ...month then press the button under Set Next The highlight will move to the day of the month display Using the UP DOWN buttons select the current date then press Set Next The highlight will move to the...

Страница 17: ...ou to adjust the appliance to your specific elevation Press the UP DOWN buttons to select your elevation The message in the center will change between NORMAL and HIGH If you select HIGH it will replac...

Страница 18: ...YPE TURNING ON APPLIANCE 7 Fill the hopper with fuel If the hopper was completely empty or has run out of fuel put approximately 1 2 cup of pel lets into the firepot for a quick restart 8 Be sure the...

Страница 19: ...RVICE RETRY ERROR LIST 1 If the appliance has stopped operat ing check the wall control screen If it is showing Min Firepot Temp the hopper has run out of fuel 2 Fill the hopper with fuel and press th...

Страница 20: ...ge the battery Figure 20 3 MAINT BURN 73 Set at 73 12 30 PM HEAT OUTPUT MENU Maint Burn will display when the thermostat has reached the set room temperature and will run on low until it reaches its a...

Страница 21: ...ing or Inspection Frequency Daily Weekly Every 2 Weeks Monthly Yearly Ash Pan Burning Wood Pellets Every 5 bags of fuel OR X Ash Pan Burning Alternate Fuels Every 1 bag of fuel OR X Ash Removal from F...

Страница 22: ...gular intervals depending upon use and fuel quality Frequency Monthly or every ton aprx 50 bags or more frequently depending on the type of fuel By Homeowner a Be sure the wall control screen says OFF...

Страница 23: ...fully closed when finished 6 Cleaning Heat Exchanger Drop Tube Exhaust Frequency Monthly or every 1 ton of fuel aprx 50 bags By Homeowner NOTE There are heavy duty vacuum cleaners specifically designe...

Страница 24: ...ool 2 Attach a hose 1 2 inch 12 7mm in diameter and approximately 2 feet 607mm in length to your vacuum hose 3 Use a bottle brush and push the ash down to the bottom Remove the combustion exhaust blow...

Страница 25: ...wer Requires No Lubrication Frequency Yearly or as needed By Homeowner a Be sure the wall control screen says OFF and the appliance is allowed to cool b Use a soft brush and vacuum to clean the propel...

Страница 26: ...ly during heating season By Qualified Service Technician Homeowner This chimney should be inspected periodically during the heating season to determine if a creosote build up has oc curred If a signif...

Страница 27: ...t Clear jam and Press Retry MISSED IGNITION Igniter bad or poor harness connection Out of fuel or fuel is bridging in hopper Faulty firepot thermocouple connection has shorted Ash plugging the igniter...

Страница 28: ...screw driver into the slot of the latches located in the upper corners and push down The bottom of the latch will fall forward off of the post Lift the baffle up and then out toward you Figure 28 2 e...

Страница 29: ...ng first then rotate blower up into position 10 When the blower is properly positioned the latch will engage the notch to hold the blower in place Figure 29 3 11 Re secure the back panel snap the powe...

Страница 30: ...the appliance An icon will display on the wall control when the appliance has lost main power and is running on battery back up 4 Combustion Exhaust Blower The combustion exhaust blower is mounted in...

Страница 31: ...ermocouple Drop Tube This thermocouple is located on the bottom of the drop tube on the right side and attached with a wing nut It turns the convection blower on and off varies the speed of the convec...

Страница 32: ...ver Heat Exchanger Front Back Figure 32 1 RIGHT SIDE Combustion Blower Vacuum Switch Feed Motor Overheat Sensor Wing Nut Securing Overheat Sensor in place Power Supply Low Fuel Indicator Control Board...

Страница 33: ...Sept 2006 Ending Manufacturing Date Active Pellet Stove MTVERNON AE CSB MTVERNON AE MBK MTVERNON AE PMH MTVERNON AE PBK MTVERNON PFT MTVERNON PDB MTVERNON AE CWL Sept 2006 thru June 2011 1 2 3 4 5 6...

Страница 34: ...t 7034 157PFT Sienna Bronze 7034 157CSB Willow 7034 157CWL Mahogany 7034 157PMH Gasket Hopper Lid 10 FT 7000 320 10 Gasket Hopper Front Back SRV7034 236 2 2 Magnet Round SRV7000 140 Y 2 3 Hinge Arm Ri...

Страница 35: ...107CSB Willow 7005 107CWL Mahogany 7005 107PMH 6 Side Mount Left 7034 128 7 Baf e SRV7034 263 Y 8 Latch Baf e 7034 149 9 Intake Shield 7034 224 Y 10 Door Assembly 7034 006 10 1 Hinge Female 450 2910 1...

Страница 36: ...Frost 7005 111PFT Sienna Bronze 7005 111CSB Willow 7005 111CWL Mahogany 7005 111PMH 14 Door Right Matte Black 7005 109MBK Porcelain Black 7005 109PBK Porcelain Dark Blue 7005 109PDB Porcelain Frost 7...

Страница 37: ...trol Board Assembly SRV7000 456 Y Fuse 15A Slow Iec Glass Pkg of 10 7000 491 10 Y 31 Snap Disc Manual Reset SRV230 1290 Y 32 Rear Shroud 7034 170 33 Feed Assembly SRV7034 004 Y 33 1 Feed Spring Assemb...

Страница 38: ...2 Half Clip Thermocouple Holder 7000 321 35 3 Thermocouple Protection Tube Thermocouple Cover SRV7034 186 Y 35 4 Firepot Assembly Upper SRV7034 072B Y 35 5 Gasket Firepot 7034 190 Y 35 6 Auto Clean Li...

Страница 39: ...RV7034 035 Mahogany SRV7034 037 Cleanout Tool 414 1140 Y Dvd Advanced Energy 7000 335 Leveling Assembly 7000 000 Paint Touch Up Matte Black 812 0910 Mahogany 855 1450 Sienna Bronze TOUCHUP CSB Willow...

Страница 40: ...lville WA 99114 Division of HNI INDUSTRIES Please contact your Quadra Fire dealer with any questions or concerns For the number of your nearest Quadra Fire dealer log onto www quadrafire com This prod...

Отзывы: