background image

March 19, 2003                                                                       20                       

 

 

 

    250-6422

                                                                                           

Castile Pellet Stove

R

WIRING HARNESS

Gr

ee

w/

pi

nk

 s

pa

de

YELLOW 

w/WH

Y

E

L

L

O

W

 w

/W

H

THERMOCOUPLE

 T.C.

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

T-STAT CONN

(YELLOW w/WH)

SNAP DISC #2

(GRAY)

SNAP DISC #3

CONV. BLOWER 

AUGER MOTOR

(BLUE)

COMB. BLOWER

(WHITE)

NEUTRAL IN

NEUTRAL AUGER

NEUTRAL CONV.
NEUTRAL COMB.

NEUTRAL IGN.

(HT)

M

(RED/WHT)

SNAP DISC #1

M

IGNITER

(HT)

M

BURN RATE

LIGHT

P.B.

FUSE

AUG

.

CAP.

ORANGE

BLUE

GRAY

BLAC

K

YELLO

W

RE

D

ORANGE

BLUE

YELLO

W

YELLO

W

RE

D

PURPL

E

BLUE

HI-TEMP

HI-TEMP

(RED)

VAC.

SWITCH

NEUTRA

L

WHIT

E

BL

K

RE

D

WHIT

E

BLK

BL

K

GRAY

(ORANGE)

(PURPLE)

(RED)

(YELLOW)

(GRAY)

(ORANGE)

(PURPLE)

BLACK

WHIT

E

(BLACK)

(WHITE)

(WHITE)

(WHITE)

ACCY JUMPER

4

5

6

3

2

1

Содержание QUADRA-FIRE

Страница 1: ...OVERFIRING VOIDS WARRANTY 5 DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM DO NOT INSTALL A FLUE DAMPER IN THE EXHAUSE VE...

Страница 2: ...inserts and fireplaces And yet we are old fashioned when it comes to craftsmanship Each unit is meticulously fabricated and gold surfaces are hand finished for lasting beauty and enjoyment Our pledge...

Страница 3: ...Chimney and Exhaust Connections 5 Venting Termination Requirements 5 Vent Graph and Table 5 Venting Systems A Alcove 6 B Through the wall 6 C Vertical 7 D Through the wall and vertical 7 E Masonry 7 F...

Страница 4: ...and to the sides front and back of unit as shown in Floor Protection Diagram Measure front distance I from the surface of the glass door Exceptions US INSTALLATIONS Recommend a non combustible floor...

Страница 5: ...shielding or guards may be required 3 Termination must exhaust above air inlet elevation It is recommended that at least 60 1524mm of vertical pipe be installed when appliance is vented directly thro...

Страница 6: ...5 Degree VENTING SYSTEMS Straight Out A ALCOVE The Quadra Fire Castile is approved for minimum alcove height of 43 1092mm a maximum alcove depth of 36 914mm and a minimum alcove side wall of 6 152mm A...

Страница 7: ...Cap Flashing 2 51mm minimum 6 152mm minimum VENTING SYSTEMS CONT C VERTICAL D THROUGH THE WALL VERTICAL E MASONRY F ALTERNATE MASONRY Non combustible Hearth Pad Airtight Cleanout Door Cleanout cover S...

Страница 8: ...nt Adapter remove clean out cover NOTES 1 The Feed Adjustment Rod is factory set and should be adequate for most fuels However if the flame height is too high or too low follow the instructions below...

Страница 9: ...ZE AND MATERIAL Wood Pellets Fuel pellets are made from sawdust or wood by products If the source material is hardwood they will have a higher mineral content creating a heavier ash Minerals and other...

Страница 10: ...es in that when the thermostat calls for heat your stove will automatically light and deliver heat in the most efficient and economical way When the room is up to temperature and the thermostat is sat...

Страница 11: ...ppermost portion of the Heat Exchanger Tubes This area is only accessible when the baffle is removed from the stove Reinstall panels and baffle and latch when finished cleaning NOTE Unplug the stove b...

Страница 12: ...this removed the blower and housing may now be removed There are four screws that attach the blower housing Two on each side Loosen all four screws but do not remove them Now lift the blower housing...

Страница 13: ...s to indicate that the stove has reached operating temperature If the red light does not come on in the first nine minutes of start up the stove will shut 1 POWER SUPPLY a Check the wall receptacle fo...

Страница 14: ...surges can also trip this Snap Disc To reset unplug the stove from outlet and push in the Red Reset Button in the center of the Snap Disc then plug the stove back in and try to relight it 13 BLOWER 1...

Страница 15: ...sure that the floor of the firepot is closing completely 18 DOOR GASKET ROPE a To inspect the door gasket rope open the door and see that the door rope extends approximately 1 8 3mm to 3 16 9 5mm fro...

Страница 16: ...ews 5 Measure distance from floor to air vent opening in stove and mark location on wall Use saw to cut opening in wall Cut a 2 1 2 to 3 64mm to 76mm opening on inside wall and a 3 to 3 1 2 76mm to 89...

Страница 17: ...he top baffle and the inside of the firebox cen tered from side to side The latch pivots up and down 2 Push the latch up with your finger while sliding the top baffle forward and down See Figure 17A 3...

Страница 18: ...he Thermocouple and the Thermocouple Cover should extend approximately 1 25mm into the firepot for accurate temperature reading 3 Push the Reset Button When the Thermocouple reaches 200 F 93 C the TRO...

Страница 19: ...jumper wire in order to create a manual bypass to determine if the stove or the thermostat is faulty NOTE Unplug the stove while hooking up the jumper wire Plug the stove back in and the unit should...

Страница 20: ...AUGER MOTOR BLUE COMB BLOWER WHITE NEUTRAL IN NEUTRAL AUGER NEUTRAL CONV NEUTRAL COMB NEUTRAL IGN HT M RED WHT SNAP DISC 1 M IGNITER HT M BURN RATE LIGHT P B FUSE AUG CAP ORANGE BLUE GRAY BLACK YELLOW...

Страница 21: ...ot scraper paint fasteners power cord wire harness thermostat igniter owner s manual video and warranty card 812 4940 Control Box 812 4890 Door Assembly with Glass 812 4421 Feed Motor 812 4430 Firepot...

Страница 22: ...llet Stove R 3 4 5 6 2 1 7 8 9 10 11 12 1 Control Box 2 Convection Blower 3 Exhaust Blower 4 Feed Motor 5 Firepot 6 Glass Door Assembly EXPLODED VIEW 7 Igniter 8 Junction Box 9 Snap Disc 1 10 Snap Dis...

Страница 23: ...essories Adjustments regular maintenance cleaning and temporary repairs do not qualify for a service call fee and will not be covered The replacement of consumer replaceable items and installation of...

Страница 24: ...March 19 2003 250 6422 24 PLEASE RETURN THESE INSTRUCTIONS TO THE HOME OWNER WHEN INSTALLATION IS COMPLETE ATTENTION INSTALLER R...

Отзывы: