7095-818
19
Quadrafire • Expedition II AU Install Manual_Rev B • 2020 - ___ • 09/20
B. Stove Pipe or Liner to Flue Collar
1.
There are 4 already drilled holes in the flue collar 90
degrees apart. Attach the flue collar to the stove pipe/
liner. If the seal is questionable use high temperature
sealant such as stove mastic
(Figure 5.3)
.
2.
Attach gasket to bottom side of flue collar with a thin coat
of silicone.
C. Optional Offset Adapter
Optional use of a Simpson Duravent 15° Universal Elbow
Part Number 4615 may be purchased directly through your
local Simpson Duravent Pipe Distributor or from your local
Quadra-Fire dealer, Part Number DV-6DLR-E15ADSS.
Figure 5.4
shows a vertical installations and also how to
create an optional 30° elbow installation.
The 15° elbow may be secured directly to the flue collar.
Follow the pipe manufacturer’s instructions for using screws
or rivets for attachment. Most pipe manufacturer’s 6 inch
(152mm) diameter flue liners may be attached directly to the
top of the 15° elbow.
D. Power Cord
The power cord is shipped assembled to the appliance.
You may route the power cord either to the left or right
side depending on your configuration for power source
(Figure 5.5)
.
Flue Collar
Stove Pipe/Liner
Gasket
Figure 5.3
Figure 5.4
30 degree
30
o
Vertical
Figure 5.5
E. Appliance to Stove Pipe or Liner
1.
Once you have the appliance in place and secured, reach
up through the flue opening and grab the attachment bar
and pull down inside flue opening
(Figure 5.6)
.
2.
Insert the 5/16 bolts inside the cast flue and through
the chimney mounting bar. Securely tighten the nuts;
fasteners are provided.
3.
Re-install the tube channel assembly, baffle board,
ceramic blanket and baffle protection channel.
5/16 Nuts
Attachment
Bar
5/16 Bolts
Figure 5.6