1100KL ASSEMBLY INSTRUCTIONS (CONTINUED) 

 

Assembling the 1100KL Scale (Refer to Figures 1-7) 

 

Caution: It is recommended that the assembly be performed by two persons.   

 

1.  Remove the scale platform from the carton and place scale platform on a flat, level, and dry 

surface. 

2.  Locate and pick up the center handrail. Find the load cell cable connector, located at the 

bottom of the center handrail. Untie it and pull it out the bottom (see Figures 2 & 3). 

3.  Position the center handrail over the handrail supports on the platform and feed the cable 

through the handrail support hole located on the right handrail support in the platform. Be sure 
not to pinch the cable (see Figures 2, 3, & 7). 

4.  Position the center handrail over the left and right handrail supports on the platform. 

Fasten the handrail to the platform using (4) M8 1.25 x 3/8 screws (B) and (4) M8 
washers (E). Use the 5mm Allen wrench to tighten the screws. Do not over tighten       
(see Figures 1, 2 & 4).   

5.  Loosely attach the left and right side handrails to the center handrail, using (4) M10 1.5 x 1 

½ screws (A). Use the 8mm Allen wrench to fasten the screws (see Figures 1 & 2). 

6.  Pull forward on the side handrails to tip the scale and gently place it face down on the floor. 

7.  Grasp the load cell cable protruding from the bottom of the base of the scale and feed it 

through the protective metal shield above the wheel. Plug the connector into the load cell port 
located on the side of the platform (see Figure 7). 

8.  Pull the excess cable through the top of the center handrail (see Figure 2). 

9.  Thread the (4) feet into the underside of the platform. Each foot should be completely hand 

tightened. Once tighten, back feet out 1-½ full turns. This allows for proper load cell operation 
for accuracy of the scale (see Figures 2 & 7). 

10. Carefully tilt the scale back to an upright position on the floor. 

 

Warning: Do not drop scale, as this can permanently damage the load cells. 

 

11. 

 

Adjust the feet to level the scale. Be certain that the feet are not completely tightened into the 

platform (refer to the scale platform - feet assembly instruction above).  

12. Position the display assembly close to the display support.  Plug the load cell cable connector 

into the load cell port on the rear of the display assembly (see Figures 2 & 6). 

Note

: Do not attach the power cord at this point. 

13. Align the four mounting holes on the back of the display assembly with the four mounting 

holes in the display support. Fasten the display assembly onto the metal display support by 
using (4) Phillips pan head M4 screws (D). Use Phillips head screwdriver to tighten the screws 
(see Figures 1 & 5). 

Содержание PROPLUS 1100KL

Страница 1: ...Model 1100KL Digital Handrail Scale User Instructions P N UM1100KL Rev 3 080613 1...

Страница 2: ...ns Connectivity Disposal 5 Assembly Instructions 1100KL Scale 6 Setup Batteries 12 Quick Start Instructions 14 Maintenance 18 Calibration 19 Troubleshooting 20 Warranty 21 Note This scale has been fac...

Страница 3: ...come in contact with liquids excessive temperature or excessive humidity Operating this scale at voltages and frequencies other than specified can damage the equipment and will void the warranty Do no...

Страница 4: ...handrails for patient comfort and safety It also has a 180 swivel display head for privacy and easy operator reading from either side of the scale This scale has 2 wheels built in for easy mobility T...

Страница 5: ...Index BMI data this scale is designed to connect to a computer monitor or other electronic device via a built in USB port This connectivity helps minimize a source of potential medical errors caused b...

Страница 6: ...y remove each assembly from the carton and unwrap the packing materials Set the carton aside for storage To avoid damaging the scale parts when unpacking do not use a box cutter knife scissors or any...

Страница 7: ...n on the floor 7 Grasp the load cell cable protruding from the bottom of the base of the scale and feed it through the protective metal shield above the wheel Plug the connector into the load cell por...

Страница 8: ...to the center rail using 2 8 x sheet metal screws C Use Phillips head screwdriver to tighten the screws see Figures 1 2 16 Connect the AC adapter to the power port in the display Do not plug the scale...

Страница 9: ...1100KL ASSEMBLY INSTRUCTIONS CONTINUED Figure 1 Figure 2 9...

Страница 10: ...1100KL ASSEMBLY INSTRUCTIONS CONTINUED Center handrail Load cell cable Scale platform Figure 3 Figure 4 Figure 5 10...

Страница 11: ...1100KL ASSEMBLY INSTRUCTIONS CONTINUED Figure 6 Protective metal shield Cable connector Load cell port Figure 7 11...

Страница 12: ...KG 6 When the AC adapter is disconnected from the scale the scale will switch to battery power if batteries are installed Note If the set up procedure failed refer to the troubleshooting instructions...

Страница 13: ...SETUP BATTERIES CONTINUED Figure 8 13...

Страница 14: ...ta to calculate patient s Body Mass Index BMI RECALL Recalls the previous weight TARE PRETARE TARE Tares out weight of an object on the platform PRETARE Prompts entry of a tare value that will be dedu...

Страница 15: ...scale will automatically deduct the tare weight of the object from the gross weight of the patient and object together 7 The weight of the patient will appear on the scale 8 With no weight on the scal...

Страница 16: ...tient s weight when the stable weight of the patient is determined Depending on the movement of the patient on the scale it may take several seconds for the scale to lock onto the weight 5 Once a weig...

Страница 17: ...t information and will lock on the patient s weight when the stable weight of the patient is determined Depending on the movement of the patient on the scale it may take several seconds for the scale...

Страница 18: ...pect the AC adapter for cord cracking or fraying or for broken bent prongs Note This scale is an extremely sensitive weighing device If the auto off function is disabled battery power will be consumed...

Страница 19: ...nt number 2 Press the ENTER button CAL 3 Make sure there is nothing on the scale then press the ENTER button Clear followed by 0400 0LB 4 Use the and buttons to set the calibration weight to a value o...

Страница 20: ...ot placed on a level floor 3 Place the scale on a level floor and begin weighing process again 4 Scale is out of calibration 4 Check weight with known weight value 5 Improper Tare 5 Place the item to...

Страница 21: ...nsit or unauthorized repair or alternations Further the warranty does not cover natural disasters such as fire flood hurricanes and tornadoes This warranty gives you specific legal rights and you may...

Отзывы: