1100KL ASSEMBLY INSTRUCTIONS (CONTINUED) 

 

 

14. Place the pivot bracket screw covers over the pivot screws. Fasten the covers to the back of 

the display using (4) Phillips pan head M4 screws (D). Use Phillips head screwdriver to tighten 
the screws (see Figures 1 & 5). 

15. Attach the adapter holder to the center rail using (2) #8 x ½ sheet metal screws (C). Use 

Phillips head screwdriver to tighten the screws (see Figures 1 & 2). 

16. Connect the AC adapter to the power port in the display. Do not plug the scale into a power 

source until the scale is fully assembled (see Figure 6). 

17. Attach the front and rear display support covers, applying light pressure to snap these covers 

into place (see Figure 2). 

18. The scale is now assembled. Plug the AC adapter into a power source and / or insert 

batteries. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание PROPLUS 1100KL

Страница 1: ...Model 1100KL Digital Handrail Scale User Instructions P N UM1100KL Rev 3 080613 1...

Страница 2: ...ns Connectivity Disposal 5 Assembly Instructions 1100KL Scale 6 Setup Batteries 12 Quick Start Instructions 14 Maintenance 18 Calibration 19 Troubleshooting 20 Warranty 21 Note This scale has been fac...

Страница 3: ...come in contact with liquids excessive temperature or excessive humidity Operating this scale at voltages and frequencies other than specified can damage the equipment and will void the warranty Do no...

Страница 4: ...handrails for patient comfort and safety It also has a 180 swivel display head for privacy and easy operator reading from either side of the scale This scale has 2 wheels built in for easy mobility T...

Страница 5: ...Index BMI data this scale is designed to connect to a computer monitor or other electronic device via a built in USB port This connectivity helps minimize a source of potential medical errors caused b...

Страница 6: ...y remove each assembly from the carton and unwrap the packing materials Set the carton aside for storage To avoid damaging the scale parts when unpacking do not use a box cutter knife scissors or any...

Страница 7: ...n on the floor 7 Grasp the load cell cable protruding from the bottom of the base of the scale and feed it through the protective metal shield above the wheel Plug the connector into the load cell por...

Страница 8: ...to the center rail using 2 8 x sheet metal screws C Use Phillips head screwdriver to tighten the screws see Figures 1 2 16 Connect the AC adapter to the power port in the display Do not plug the scale...

Страница 9: ...1100KL ASSEMBLY INSTRUCTIONS CONTINUED Figure 1 Figure 2 9...

Страница 10: ...1100KL ASSEMBLY INSTRUCTIONS CONTINUED Center handrail Load cell cable Scale platform Figure 3 Figure 4 Figure 5 10...

Страница 11: ...1100KL ASSEMBLY INSTRUCTIONS CONTINUED Figure 6 Protective metal shield Cable connector Load cell port Figure 7 11...

Страница 12: ...KG 6 When the AC adapter is disconnected from the scale the scale will switch to battery power if batteries are installed Note If the set up procedure failed refer to the troubleshooting instructions...

Страница 13: ...SETUP BATTERIES CONTINUED Figure 8 13...

Страница 14: ...ta to calculate patient s Body Mass Index BMI RECALL Recalls the previous weight TARE PRETARE TARE Tares out weight of an object on the platform PRETARE Prompts entry of a tare value that will be dedu...

Страница 15: ...scale will automatically deduct the tare weight of the object from the gross weight of the patient and object together 7 The weight of the patient will appear on the scale 8 With no weight on the scal...

Страница 16: ...tient s weight when the stable weight of the patient is determined Depending on the movement of the patient on the scale it may take several seconds for the scale to lock onto the weight 5 Once a weig...

Страница 17: ...t information and will lock on the patient s weight when the stable weight of the patient is determined Depending on the movement of the patient on the scale it may take several seconds for the scale...

Страница 18: ...pect the AC adapter for cord cracking or fraying or for broken bent prongs Note This scale is an extremely sensitive weighing device If the auto off function is disabled battery power will be consumed...

Страница 19: ...nt number 2 Press the ENTER button CAL 3 Make sure there is nothing on the scale then press the ENTER button Clear followed by 0400 0LB 4 Use the and buttons to set the calibration weight to a value o...

Страница 20: ...ot placed on a level floor 3 Place the scale on a level floor and begin weighing process again 4 Scale is out of calibration 4 Check weight with known weight value 5 Improper Tare 5 Place the item to...

Страница 21: ...nsit or unauthorized repair or alternations Further the warranty does not cover natural disasters such as fire flood hurricanes and tornadoes This warranty gives you specific legal rights and you may...

Отзывы: