Mechanical construction and mounting hints
4.1
PW20i design
Digital PW20i load cells are characterized by a compact aluminum-
measuring body and are designed with IP 65 protection. The electronics are
integrated in the measuring body.
19
19
118
65
33
M6
7,5
M6
33
15
10
63
10
15
30
7
66
31,5
Fig. 4.1
PW20i dimensions (in mm; 1 mm = 0.03937 inches)
4.2
Before start-up
The following precautionary measures must be complied with during
mounting and operation:
•
The length of the fastening screws must be selected so that the maximum
screw-in length of 10 mm is not exceeded. Non-compliance can cause
damage to the load cell.
•
The integrated overload protection acts in positive and negative load
directions. Please note the permissible maximum values for eccentric loads
and take into account overloads from knocks.
•
Avoid force shunts during setup.