Mechanical installation
PW15PH
A03392_02_Y00_00
HBM: public
11
4.2
Load application
Attach the load cells at the mounting holes and apply the load to the other end.
The table below contains the required screws and tightening torques:
Maximum capacities
Thread
Min. property class
10
…
100kg
M6
10.9
14 N
⋅
m
1)
Recommended value for the specified property class. Please note the information on screw
dimensions provided by the screw manufacturer.
Important
Load must not be applied to the side where the cable connection is located, as
this would cause a force shunt.
Mounting
=
=
=
=
Load application
Platform center
Spacing washer
Connector plug
Fig. 4.1
Installation