![HBK U9C Скачать руководство пользователя страница 24](http://html1.mh-extra.com/html/hbk/u9c/u9c_mounting-instructions_2111685024.webp)
U9C
ELECTRICAL CONNECTION
22
If a suitable amplifier is connected (e.g. QuantumX from HBM), the amplifier electronics
will read the TEDS chip and parameterization will then be implemented automatically,
without any intervention required by the user.
The chip content can be edited and modified with suitable hardware and software. This
can be achieved with HBM’s Quantum Assistant or DAQ CATMAN software, for instance.
Please pay attention to the operating manuals of these products.
8.2
Electrical connection of measuring amplifier with amplifier module
8.2.1
General information
If you have ordered the sensor with an inline amplifier, the inline amplifier and force trans
ducer form a measurement chain that cannot be separated. The measurement chain is
accordingly calibrated as a unit, meaning the test record (or calibration certificate) di
rectly indicates the relationship between the force (in Newtons) and the output signal (in
V or mA).
In order to guarantee a reliable measurement even under the influence of
electromagnetic fields, the housings of the inline amplifier and the sensor are connected
to the cable shield. This means that the sensor, cable and amplifier housing form a Fara
day cage. This concept is failsafe and highly insensitive to interference.
Note that the thread of the M12 device plug, by which you make the connection to the
next link in the measurement chain, is also electrically connected to the amplifier housing,
and so ultimately to the sensor housing.
If the housing of the inline amplifier and the sensor are at different electrical potentials,
compensating currents may flow through the cable shield and influence the measure
ment. So make sure that all components are at the same electrical potential. If you are
daisy-chaining the shield of the cable connected to the M12 device plug, the next compo
nent in the chain must also be set to the potential of the sensor and amplifier housing.
Use low-ohm connections for potential equalization.
A compressive force load will result in a rising current or voltage signal.
Содержание U9C
Страница 3: ...U9C ENGLISH DEUTSCH FRAN AIS ITALIANO Mounting Instructions...
Страница 5: ...3 U9C TABLE OF CONTENTS 9 Dimensions 24 10 Specifications 29 10 1 Versions and ordering numbers 33...
Страница 37: ...U9C ENGLISH DEUTSCH FRAN AIS ITALIANO Montageanleitung...
Страница 69: ...U9C ENGLISH DEUTSCH FRAN AIS ITALIANO Notice de montage...
Страница 105: ...U9C ENGLISH DEUTSCH FRAN AIS ITALIANO Istruzioni per il montaggio...
Страница 107: ...3 U9C SOMMARIO 9 Dimensioni 28 10 Dati tecnici 33 10 1 Versioni e no ordine 37...
Страница 143: ...39 U9C DATI TECNICI...
Страница 144: ...HBK Hottinger Br el Kjaer www hbkworld com info hbkworld com A03815 03 YI0 02 7 0111 0012...