THE FAB
6.3 Operation via DMX512/RDM
THE FAB can be
controlled
via
DMX512.
As
shown,
the
current
DMX
address appears in
the value range.
Below this, the set
DMX mode (2 or 3
channel mode) can
be read. With the plus and minus keys the address can be changed. Setting by
numeric keypad is also possible as described above.
If a valid DMX signal is present, this is indicated by a green bar to the right of the
DMX address.
The first channel is always for the pump value. The second channel controls the fan
speed and the third channel the air baffles (if 3-channel mode is active).
Via RDM THE FAB is configurable (DMX address) as well as readable (errors, speeds,
fluid level etc.).
6.4 Operation via Ethernet
When operating via Ethernet, the Art-NetTM and sACN protocols are supported.
The difference to the DMX operation is that here the DMX data reach the device via an
Ethernet connection. Furthermore, the DMX channels are set as described above.
The protocol relevant values are set in the following menus.
An existing Ethernet link is shown at the top center of the display.