manualshive.com logo in svg
background image

Vax Commercial Careline: (UK) 0330 026 4275

vaxcommercial.co.uk

A leading brand from one of the world’s 

largest floor care manufacturers.

VCSD-04

User Guide

VCSD-04

Содержание VCSD-04

Страница 1: ...Vax Commercial Careline UK 0330 026 4275 vaxcommercial co uk A leading brand from one of the world s largest floor care manufacturers VCSD 04 User Guide VCSD 04 ...

Страница 2: ... held responsible for injuries to persons or damage to property due to non compliance with the aforementioned instructions 2 Before using the machine make sure that each part is in the correct position 3 Do not use charger if the cable is damaged Contact Vax Commercial Careline UK 0330 026 4275 4 The machine should only be used by personnel who have received appropriate training 5 To avoid unautho...

Страница 3: ... roads or public passageways and in outdoor environments in general 10 The machine operating temperature range is 4 C to 35 C when not being used store the machine in a dry and non corrosive environment within a temperature range of between 10 C and 50 C When using the machine under any condition the humidity must range between 30 and 95 10 Never use or vacuum liquids gases dry dust acids and solv...

Страница 4: ...Do not use the machine as a support surface for any weight for any reason 17 Do not block or cover any openings 18 Do not remove modify or by pass the safety devices 19 The appropriate Personal Protective Equipment should be worn to operate the machinery and protect the user This should be in accordance with an appropriate risk assessment prior to its first use 20 Before starting work remove neckl...

Страница 5: ...s The batteries should always be clean and dry to avoid surface leakage currents 26 Protect the batteries against impurities such as metallic dust 27 Do not place tools on top of the batteries they may cause a short circuit or an explosion 28 Only clean the machine in accordance with this user guide 29 Recovered fluids contain detergents disinfectants water as well as organic and inorganic materia...

Страница 6: ...handle hidden 5 Bumper wheel 6 Brush plate 7 Brush head 8 Squeegee 9 Power lever 10 Ignition key 11 Battery security connector 12 Brush lever 13 Squeegee height lever 14 Water flow control 15 Battery security connector 16 Dirty water tank drain hose 17 Suction hose 18 Clean water tank drain underneath 19 Squeegee assembly 20 Squeegee 2 20 3 10 18 1 6 8 2 4 11 12 13 15 17 19 6 5 7 ...

Страница 7: ...27 Suction hose 28 Suction hose squeegee connection 29 Squeegee fast fixing nodule 30 Squeegee blade 31 Squeegee wheels 32 Squeegee pressure fixing nodule Technical Specification Vacuum motor 480 watt Brush motor 250 watt Brush speed 150rpm Clean water capacity 44L Dirty water capacity 55L Weight unladen 139 5kg Power 2 x 12V batteries Battery 21 22 26 30 28 29 27 23 24 25 32 31 ...

Страница 8: ...rneath the dirty water tank While the machine is in transit the batteries should be disconnected If the machine needs to be transported at any other time other than when it is in use the battery should always be disconnected Intermediate or incomplete charging while working should be avoided PLEASE READ GENERAL SAFETY INFORMATION BEFORE USE The battery pack on the machine is situated underneath th...

Страница 9: ...and centre the brush with the brush plate Line up and centre the brush with the brush plate Lift the power lever press down on the front of the machine to engage brushes Lower the brush by releasing the brush height lever Lower the brush by releasing the brush height lever Battery Battery IMPORTANT Never use the machine without brushes or if brushes are incorrectly fitted 9 Vax Careline UK 0330 02...

Страница 10: ...line up with the inserts on squeegee support bracket IMPORTANT Check squeegee blades are clean and not worn before fitting squeegee to the machine A Bumper wheel B Squeegee blades replacement nodule C Suction hose D Suction hose squeegee connection E Squeegee fast fixing nodule F Squeegee blade G Squeegee wheels H Squeegee pressure fixing nodule B F D E C A H G Line up and centre the brush with th...

Страница 11: ...026 4275 Adjusting the squeegee Filling the clean water tank Adding detergent to clean water tank Push the suction hose onto suction hose entry port IMPORTANT Only use Vax Commercial recommended detergents The use of other chemical products may not allow the machine to perform at its optimum capabilities Fill the clean water tank using a hose or similar tool Pour directly through the sponge filter...

Страница 12: ...n into a forward direction lower squeegee and the suction will automatically return to the previous position For best results maintain straight directional lines NOTE The float will rise and suction will stop when the dirty water tank is full Empty the dirty water tank Go to Draining the dirty water tank Lower the squeegee lever Direct machine forward in single passes WARNING To disable during ope...

Страница 13: ... the locking clip securely into place The hood must be airtight to avoid loss of pressure and reduction in drying efficiency Lift to remove diry water tank cover to clean through inspection hole Re fit the drain hose end cap and attach the hose onto the hook behind the machine Maintenance Lower the drain hose over the drain point WARNING Before carrying out any type of maintenance remove ignition ...

Страница 14: ...er and rubber casing Separate the filter and casing and rinse under water Remove any dirt debris rinse and under water DO NOT ALLOW WATER TO ENTER THE MOTOR FUNNEL Leave to dry for 24 hours or until fully dry before placing back into the machine Use an allen key to undo screw and remove the float 14 vaxcommercial co uk 24hr ...

Страница 15: ...ove Push and refit the water filter Twist flow tap clockwise to refit Wait until the tank has completely emptied before tightening and closing the valve Pull to remove the water filter from the flow tap Park the machine near a sewer drain or suitable location that complies with the national regulations for waste water disposal Emptying the clean water tank Cleaning the water filter IMPORTANT Make ...

Страница 16: ...technical personnel who are experts in the sector and in the pertinent safety regulations Loosen the squeegee fast fixing nodule Pull to remove the suction hose from the squeegee assembly Slide the squeegee out of the support bracket Clean squeegee under running water using a sponge or a brush Check the efficiency and the wear on the blades in contact with the floor Cleaning the squeegee 16 vaxcom...

Страница 17: ...edge of the blade which reduces pick up and therefore drying efficiency This force tends to round or to deteriorate the sharp edge of the blade reducing drying efficiency This is why the squeegee blades must be replaced Cleaning the brush Clean the brushes under running water To avoid damaging the floor and the machine carefully check if debris such as metallic parts screws chips cords or similar ...

Страница 18: ...on hole in the dirty water tank Wash the hose and remove any blockages After cleaning securely attach the suction hose to the machine and squeegee Use a sponge or a soft cloth to clean the exterior of the machine and if necessary a soft brush to remove tough dirt Steam cleaner can be used but not use a high pressure cleaner to clean the body of the machine Important Running water hotter than 50 C ...

Страница 19: ...r was pressed when the machine was turned on Release the power lever turn off and restart the machine The brushes don t rotate The brush motor switch is not selected Press the button to activate the brushes The machine is not moving forward and the brush control has tripped to avoid damaging the floor The brushes will only spin when the power lever is pressed and the machine is moving forward Pres...

Страница 20: ...djustment is not correct The assembly must be exactly perpendicular to the running direction Adjust the squeegee The suction hose and entry point the squeegees or the inspection compartment are clogged Clean out and remove any blockages The battery charger doesn t work Check that the battery charger is connected to the battery and correctly plugged into the mains Check there is no damage to the ba...

Страница 21: ...ush width Squeegee width Capacity Batteries Weight Subject to technical change without notice Technical Specification 21 Vax Careline UK 0330 026 4275 Consumables To purchase spares and accessories please visit vaxcommercial co uk or call 0330 026 4275 EEC Statement of Compliance Manufacturer EEC importer Vax Limited hereby on our own responsibility declare that the VCSD 04 series is manufactured ...

Страница 22: ...22 vaxcommercial co uk Notes ...

Страница 23: ...23 Vax Careline UK 0330 026 4275 Notes ...

Страница 24: ... 1 A leading brand from one of the world s largest floor care manufacturers Vax Ltd Plot 302 Stonebridge Cross Business Park Hampton Lovett Droitwich WR9 0LW UK email info vaxcommercial co uk website vaxcommercial co uk ...

Отзывы: