THE FAB
9. Troubleshooting
THE FAB does not haze
•
Check external control
•
Check power source
•
Check fluid quantity
•
Check connection at fluid tank for tightness
•
Check suction strainer in tank for contamination
•
Check fluid hose and connector for tightness
THE FAB clacks loudly when haze
•
The pump runs dry. This must be avoided at all costs.
•
Refill fluid
•
Check hose and coupling, engage again if necessary.
•
If the pump has run dry, hold 'the FAB' with the front side down and let it
mist for a few seconds. The fluid pump will then fill completely with fluid
again.
THE FAB shows the error message "machine too hot" in
the display
•
The temperature inside the device is too high. After cooling down, the error
disappears again.
THE FAB shows the error message "faulty vaporizer" in
the display
•
Something is wrong with the evaporator. The machine shuts down for safety
reasons.