Classic² / Highpower²
7.1 Setting the pump characteristics
After activating the submenus,
the menu fields in the corners
are changed.
The menu item "Char." now
appears at the bottom left and
the menu item "Input" at the
bottom right.
In the menu item "Char." you can choose between the pump characteristics "full
power", "max. time" and "non stop".
Full power
The pump is not regulated
down, regardless of the falling
temperature in the heating
element.
Max. Time
The pump is regulated down
depending
on
the
temperature in the heating
element. This extends the
time of the fogging process.
Nevertheless,
the
pump
switches off as soon as the
temperature falls below the
evaporation temperature.
14