Classic² / Highpower²
6.3 Operation via DMX512/RDM
When operating via DMX512, the
XLR input (2) must first be set to
DMX (see chapter Options).
As shown, "DMX" appears in the
upper right menu field. The DMX
address can be changed with the
plus and minus keys and must then
be saved with the confirmation key.
If a valid DMX signal is present, this is displayed at the top center with "active". The
currently read pump value can be displayed by selecting the pump menu item. If the
received value is greater than zero, the Classic²/Highpower² starts the fogging
process and stops it accordingly at the value zero.
Via RDM the Classic²/Highpower² is configurable (DMX address) as well as readable
(error or temperature data). Furthermore, a firmware update can be done via this
RDM input.
6.4 Operation via Modbus RTU
When operating via Modbus RTU,
the XLR input (2) must first be
set to Modbus (see chapter
Options).
The
interface
is
designed as RS485 half-duplex
connection.
The communication parameters
of the connection can be set in the "Modbus" submenu. First, the Modbus menu item
must be selected. Enter" is displayed in the value field. The confirmation key is used
to access the submenu for Modbus.